- • Requirements for the controlled devices
- • Dashboards, Zones, Categories
- • Simple thermostat with hysteresis
- • Simple Heating management using Weekly schedule and Presence switch
- • Power limiting
- • Notification on high temperature (DEPRECATED)
- • Configuring hysteresis control via Equation Smart Rule
- • PID Temperature regulation
- • PID Cascade
- • Regulation of Boiler Cascade
- • Equithermic regulation
- • Heating control in high electricity tariff via load management tariff indicator input
- • Heating and Cooling modes
- • Editing multiple devices
- • Integrate multiple control units Core
- • Safe values
- • How to combine two daily schedules in one day
- • Grouping or linking devices together
- • Using statistic values in Smart Rules
- • Hot water circulation pump control
- • Exporting data from TapHome into Google Spreadsheet using Integromat
- • Exporting device descriptions
- • 2022.2
- • 2022.1
- • 2021.3
- • 2021.2
- • 2021.1
- • 2020.1
- • 2019.1
- • 2018.1
- • 2017.1 - Blinds automation - angle control update
- • 2017.1 - Blinds automation - Depth of sun rays
- • 2017.1 - Charts updated
- • 2017.1 - Core update from the app
- • 2017.1 - Double click and triple click
- • 2017.1 - Expose devices
- • 2017.1 - Multi-value switch
- • 2017.1 - Permissions
- • 2017.1 - Replace module action
- • 2017.1 - Set to Automatic mode - "Push buttons event" Smart Rule
- • 2017.1 – Daily schedule Smart Rule
- • Firmware changelog
- • Transition of MAC address handling
- Documentation
- Wiring info and examples
- Jablotron RS485 interface wiring
Jablotron RS485 interface wiring
The communication settings for the Jablotron series 100 and 100Plus occupy one arbitrary bus, to which no other device can be connected. Communication with the JA-121T peripheral is two-way and determines the status of individual PGs for TapHome. As the Jablotron communicator module is not designed for DIN rail mounting and its installation is required to meet all requirements for security level GRADE2, mount the peripheral directly in the control panel and connect both control units only with the recommended cable. The second option is a box along the route, which has an active intrusion sensing circuit - sabotage. Also keep in mind the fact that any burglar alarm must not be controlled by a third party in accordance with the set of standards STN EN 50 131, if the safety and guaranteed level of security GRADEx, which is given by the certificate of the accredited testing laboratory and manufacturer, is to be observed. Currently, it is only possible to load PG statuses and it is not possible to write a PG status or section change.