Vaillant aroTHERM plus + sensoCOMFORT VRC 720 / multiMATIC VRC 700 (eBUS, micro-ebusd)

Predložak zajednice za dizalicu topline Vaillant aroTHERM plus s regulatorom sensoCOMFORT VRC 720 ili multiMATIC VRC 700 preko adaptera eBUS Adapter Shield ili Stick C6 s micro-ebusd. TapHome preko lokalnog HTTP API-ja adaptera čita temperature, tlak vode, snagu i potrošnju dizalice topline te podešava zadanu sobnu temperaturu i temperaturu tople vode, načine rada i jednokratno zagrijavanje tople vode.

VaillantPacket Parser → HTTP13 uređajaRevizija 1.3 Posljednje ažuriranje: 16. studenoga 2026.

Autor Martin Keller

Vaillant aroTHERM plus + sensoCOMFORT VRC 720 / multiMATIC VRC 700 (eBUS, micro-ebusd)

Uvoz u aplikaciju TapHomeHardver › Packet Parser › Dodaj iz predloška

Preuzmite predložak
Na ovoj stranici

Potreban je vanjski pristupnik (gateway)

eBUS Adapter (ebusd.eu) eBUS Adapter Shield or Stick C6 with micro-ebusd (HTTP JSON API, port 80) — stranica proizvoda

Adresa u mreži

TapHome komunicira s uređajem na adresi unesenoj pri uvozu. Dodijelite uređaju stalnu adresu — rezervaciju IP adrese u usmjerivaču ili njegovo mDNS ime ako ga podržava — inače integracija prestaje raditi kada usmjerivač promijeni adresu.

Priprema mreže

Upute za integraciju

Predložak Vaillant aroTHERM plus povezuje TapHome s dizalicom topline zrak-voda Vaillant aroTHERM plus i njezinim sustavnim regulatorom sensoCOMFORT VRC 720 ili multiMATIC VRC 700 preko adaptera eBUS Adapter Shield ili Stick C6 tvrtke ebusd.eu. Adapter je na sabirnici eBUS regulatora i na njemu radi micro-ebusd, koji dekodira poruke Vaillant i nudi ih preko lokalnog HTTP JSON API-ja. TapHome komunicira samo s adapterom u lokalnoj mreži; oblak se ne koristi.

Predložak čita vanjsku, sobnu i temperaturu polaza te temperaturu tople vode, tlak vode, snagu i potrošnju dizalice topline i greške regulatora. Podešava zadanu sobnu temperaturu zone 1, zadanu temperaturu tople vode, načine rada zone 1 i tople vode te pokreće jednokratno zagrijavanje tople vode. Čita i temperature polaza, povrata i ulaznog zraka, modulaciju kompresora i aktivnost dizalice topline te podešava krivulju grijanja, najniže temperature polaza grijanja i hlađenja, način hlađenja zone 1 i histerezu zagrijavanja tople vode.

Predložak zajednice. Predložak je izrađen u portalu TapHome iz dokumentacije micro-ebusd i definicija poruka ebusd za VRC 720, VRC 700 i aroTHERM plus; iskustva s terena su dobrodošla. XML preuzmite na ovoj stranici ili iz portala TapHome: Vaillant aroTHERM plus + VRC 720 / VRC 700 — predložak zajednice, i uvezite ga kao novi modul.

Predložak dopunjuje službeni TapHome predložak eBUS Adapter Shield C6 Stick, koji preko MQTT-a prikazuje stanje samog adaptera (signal sabirnice, servis, temperaturu); oba mogu raditi jedan uz drugi. Nije povezan s predloškom zajednice za ventilokonvektor Vaillant aroVAIR, koji koristi Modbus RTU.

Što vam treba

  • Vaillant aroTHERM plus s regulatorom sensoCOMFORT VRC 720 ili multiMATIC VRC 700 na sabirnici eBUS.
  • eBUS Adapter Shield C6 ili Stick C6 (adapter.ebusd.eu) s najnovijim firmverom i aktiviranim micro-ebusd. micro-ebusd je plaćena funkcija adaptera koju otključava token; svaki adapter dobiva jednu probnu licencu od 30 dana.
  • Adapter i TapHome Core u istoj lokalnoj mreži.

Hardversko spajanje

Adapter se spaja na dvije stezaljke eBUS regulatora (VRC 720 ili VRC 700); polaritet sabirnice eBUS nije važan. aroTHERM plus komunicira s regulatorom po istoj sabirnici, pa do vanjske jedinice nije potreban vodič. Prije rada na stezaljkama regulatora isključite mrežno napajanje.

Adapter spojite u lokalnu mrežu kako je opisano u dokumentaciji adaptera i rezervirajte njegovu IP adresu u usmjerivaču, kako bi ga TapHome uvijek pronašao.

Konfiguracija

Aktivacija micro-ebusd

  1. Ažurirajte adapter na najnoviji firmver (adapter.ebusd.eu).
  2. Nabavite token micro-ebusd na token.ebusd.eu (jedna probna licenca od 30 dana po adapteru, zatim se plaća) i unesite ga u web sučelje adaptera.
  3. Nakon aktivacije HTTP JSON API odgovara na http://<adapter-ip>/api/v1/ebus.

Pronalaženje naziva krugova

micro-ebusd svaku vrijednost adresira krugom i nazivom poruke. U pregledniku otvorite http://<adapter-ip>/api/v1/ebus/list: prikazuje krugove i poruke koje je adapter pronašao na sabirnici. Regulator sensoCOMFORT VRC 720 javlja se ovisno o verziji kao ctlv2, ctlv3 ili 720, multiMATIC VRC 700 kao 700, vanjska jedinica aroTHERM plus kao hmu. Predložak podržava oba regulatora; za VRC 700 kao krug regulatora unesite 700.

Parametri uvoza

ParametarZadana vrijednostOpis
ADAPTER_IP(prazno)IP adresa eBUS adaptera
CONTROLLER_CIRCUITctlv2Naziv kruga regulatora iz /api/v1/ebus/list, na primjer ctlv2 za VRC 720 ili 700 za VRC 700
HEAT_SOURCE_CIRCUIThmuNaziv kruga vanjske jedinice aroTHERM plus

Uvoz stvara dva modula na istom adapteru: Regulator (sensoCOMFORT VRC 720 / multiMATIC VRC 700) s trinaest uređaja i aroTHERM plus (hmu) sa šest uređaja dizalice topline.

Mogućnosti uređaja

Temperature i tlak

  • Vanjska temperatura — vanjska temperatura kako je prikazuje regulator.
  • Temperatura polaza — temperatura polaza sustava (polaz grijanja).
  • Tlak vode — tlak vode u sustavu grijanja u barima (samo za čitanje).

Zona 1

  • Termostat zone 1 — sobna temperatura i zadana vrijednost koju regulator stvarno koristi. Zadana vrijednost postavljena u TapHome (5–30 °C) šalje se kao quick veto: privremena promjena na 3 sata (varijabla uređaja QuickVetoHours, 0,5–12 h); nakon toga ponovno vrijedi vremenski program regulatora. Nakon upisa predložak ponovno čita vrijednost sa sabirnice.
  • Način rada zone 1 — Isključeno, Auto (vremenski program), Ručno / Dan i Noć. Predložak preuzima nazive iz definicije koju javlja adapter: off, auto, manual s firmverom micro-ebusd od travnja 2026., off, auto, day, night sa starijim firmverom. Noć postoji samo sa starijim nazivima; sam VRC 720 ima načine Ručno, Auto i Isključeno.
  • Način hlađenja zone 1 — Isključeno, Auto i Ručno za hlađenje zone 1. Na VRC 720 potreban je firmver micro-ebusd od 22. 4. 2026. i hlađenje uključeno za krug grijanja 1; sa starijim firmverom uređaj ostaje bez vrijednosti. Na VRC 700 predložak koristi način hlađenja regulatora VRC 700, a Ručno upisuje kao day.

Polaz grijanja i hlađenja

  • Krivulja grijanja — krivulja grijanja kruga grijanja 1, od 0,1 do 4,0.
  • Najniža temperatura polaza grijanja — najniža temperatura polaza pri grijanju, od 15 do 80 °C. Regulator grije na višu od dviju vrijednosti, one prema svojoj krivulji grijanja i ove, pa s niskom krivuljom grijanja vrijednost upisana ovdje određuje temperaturu polaza; najviša temperatura polaza regulatora i dalje je ograničava. Smart rule kao što je Ekvitermna regulacija može u ovaj uređaj upisivati temperaturu polaza koju izračuna. Vrijednost se zaokružuje na cijeli stupanj i upisuje samo kad se promijeni. Regulator je sprema u trajnu memoriju: iz opreza neka je smart rule mijenja najviše otprilike jednom u 10 minuta.
  • Najniža temperatura polaza hlađenja — najniža temperatura polaza pri hlađenju, od 7 do 24 °C; nadzor rosišta regulatora može je povisiti. Na VRC 720 s firmverom micro-ebusd od 22. 4. 2026. dostupna je samo kad je hlađenje uključeno za krug grijanja 1.

Topla voda

  • Termostat potrošne tople vode — temperatura spremnika tople vode i zadana temperatura tople vode, podesiva od 35 do 75 °C.
  • Način rada potrošne tople vode — Isključeno, Auto, Ručno / Dan ili Noć (Noć samo sa starijim firmverom, vidi gore).
  • Jednokratno zagrijavanje tople vode — uključivanje pokreće zagrijavanje; kad se spremnik zagrije, regulator se sam vraća na auto, a prekidač tada ponovno pokazuje isključeno.
  • Histereza zagrijavanja tople vode — histereza zagrijavanja tople vode u K. Regulator odbija vrijednost izvan svojeg raspona; TapHome tada prikazuje vrijednost koju je regulator zadržao.

Električna energija dizalice topline

Modul aroTHERM plus (hmu) ima šest uređaja. Brojilo električne energije dizalice topline je brojilo vanjske jedinice:

  • Snaga — trenutna električna snaga dizalice topline u kW.
  • Ukupna potrošnja — ukupna potrošnja električne energije dizalice topline u kWh. Brojač je 16-bitni broj (najviše 65535 kWh), pa je na jedinici koja radi mnogo godina možda već ponovno krenuo od nule.

Prikazuje i tri servisna atributa:

Servisni atributOpis
COP (grijanje)Faktor učinkovitosti dizalice topline pri grijanju
Ukupni toplinski prinos [kWh]Ukupni toplinski prinos dizalice topline — toplinska energija, a ne električna
Radno stanjeStanje koje javlja vanjska jedinica: ready, heating, cooling, heating_water ili error

Rad dizalice topline

  • Temperatura polaza dizalice topline, Temperatura povrata dizalice topline i Temperatura ulaznog zraka — temperature koje mjeri vanjska jedinica.
  • Modulacija kompresora — modulacija kompresora u %, sa servisnim atributima brzina kompresora, temperature na ulazu i izlazu kompresora i visoki tlak.
  • Aktivnost dizalice topline — što dizalica topline radi, prema njezinom statusnom kodu: 0 pripravnost, 1 grijanje, 2 hlađenje, 3 topla voda, 4 odleđivanje, 5 ostalo (na primjer zaštita ili kvar). Servisni atribut Statusni kod prikazuje sam statusni kod.

Greške regulatora

Modul Regulator (sensoCOMFORT VRC 720 / multiMATIC VRC 700) u svakom ciklusu čita trenutne greške regulatora. Za svako od njegovih pet polja grešaka koje nije nula modul prikazuje grešku s brojem greške, na primjer Controller error code: 1025.

Kako predložak komunicira s adapterom

Svaka vrijednost je jedna poruka iz definicije ebusd. Predložak je čita s GET /api/v1/ebus/{circuit}/{message}/get?from=1, koji odgovara iz međuspremnika adaptera ili pita sabirnicu, i iz odgovora uzima data.fields.value. Upis je PUT /api/v1/ebus/{circuit}/{message}/set s tijelom {"fields":{"value":…}}, a nakon njega slijedi čitanje s from=2, koje uvijek pita sabirnicu. Moduli i svi uređaji čitaju svakih 60 s. Firmver micro-ebusd od 22. 4. 2026. koristi novije nazive poruka (OutsideTemp, Z1TempDesired, CurrentError); predložak najprije čita noviji naziv, a ako ga nema, stariji.

Nijedan uređaj ništa ne upisuje pri pokretanju centralne jedinice TapHome Core: stanje preuzimaju od adaptera, a ne od posljednje vrijednosti u TapHome.

Neke verzije firmvera VRC 720 potvrde upis, ali ga ne izvrše. Budući da predložak nakon svakog upisa ponovno čita vrijednost sa sabirnice, TapHome tada prikazuje vrijednost koju regulator stvarno koristi, a ne onu koju ste postavili.

multiMATIC VRC 700 ima manje poruka od VRC 720. Nema najnižu temperaturu polaza za hlađenje, pa Najniža temperatura polaza hlađenja ostaje bez vrijednosti. Nema trajanje quick veta: Termostat zone 1 upisuje samo temperaturu quick veta, a QuickVetoHours se ne primjenjuje. Zadana vrijednost zone 1 i vanjska temperatura dolaze iz starijih poruka Z1ActualRoomTempDesired i DisplayedOutsideTemp.

Što predložak ne radi

  • Ostali instalaterski parametri (najviša temperatura polaza i ostale instalaterske postavke) namjerno su izostavljeni — od instalaterskih postavki predložak mijenja samo krivulju grijanja, najniže temperature polaza grijanja i hlađenja i histerezu zagrijavanja tople vode.
  • Zadana temperatura hlađenja zone 1, zone 2 i 3 te tjedni vremenski program nisu dio predloška.
  • Trenutni toplinski učinak vanjske jedinice dostupan je na sabirnici, ali se ne čita.

Rješavanje problema

Nema nikakvih vrijednosti

Provjerite je li micro-ebusd aktiviran i nije li token istekao: bez micro-ebusd adapter ne odgovara na /api/v1/ebus. Provjerite otvara li se http://<adapter-ip>/api/v1/ebus/list u pregledniku.

Uređaji regulatora ne prikazuju vrijednost

Naziv kruga ne odgovara. Otvorite http://<adapter-ip>/api/v1/ebus/list, pronađite naziv regulatora (ctlv2, ctlv3 ili 720 za VRC 720, 700 za VRC 700) i vanjske jedinice (hmu) i ponovno uvezite predložak s tim nazivima.

Zadana vrijednost ili način rada vrati se na staru vrijednost

Regulator nije izvršio upis; TapHome prikazuje vrijednost ponovno pročitanu sa sabirnice. Provjerite način rada zone i firmver regulatora. Zadana vrijednost iz TapHome vraća se na vremenski program i kad quick veto istekne (QuickVetoHours).

Greška modula Controller error code: …

Regulator javlja grešku s tim brojem. Potražite je u dokumentaciji regulatora ili dizalice topline; greška modula nestaje kad je regulator poništi.

Dostupni uređaji 13

Ovi se uređaji pojavljuju u TapHomeu nakon uvoza.

sensoCOMFORT VRC 720 (ctlv2) Modul

Controller (sensoCOMFORT VRC 720 / multiMATIC VRC 700)

Čitanje (modul)
# CurrentError in the ebusd definitions micro-ebusd uses since firmware 2026-04-22, Currenterror in older firmware
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/CurrentError/get?from=1");
VAR found := false;
IF response.IsSuccess
  found := !ISNULL(PARSEJSON(response.Content, "data.fields.error", true));
END
IF !found
  response :=SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Currenterror/get?from=1");
END
IF response.IsSuccess
  VAR e0 := PARSEJSON(response.Content, "data.fields.error", true);
  VAR e1 := PARSEJSON(response.Content, "data.fields.error_1", true);
  VAR e2 := PARSEJSON(response.Content, "data.fields.error_2", true);
  VAR e3 := PARSEJSON(response.Content, "data.fields.error_3", true);
  VAR e4 := PARSEJSON(response.Content, "data.fields.error_4", true);
  IF !ISNULL(e0)
    IF e0 != 0
      ADDERROR(0, "Controller error code: " + e0);
    END
  END
  IF !ISNULL(e1)
    IF e1 != 0
      ADDERROR(1, "Controller error_1 code: " + e1);
    END
  END
  IF !ISNULL(e2)
    IF e2 != 0
      ADDERROR(2, "Controller error_2 code: " + e2);
    END
  END
  IF !ISNULL(e3)
    IF e3 != 0
      ADDERROR(3, "Controller error_3 code: " + e3);
    END
  END
  IF !ISNULL(e4)
    IF e4 != 0
      ADDERROR(4, "Controller error_4 code: " + e4);
    END
  END
END
Vanjska temperatura Senzor temperature Samo za čitanje

Vanjska temperatura kako je prikazuje regulator VRC 720

numeric Jedinica: °C

Vanjska temperatura

Čitanje temperature
# OutsideTemp in the ebusd definitions micro-ebusd uses since firmware 2026-04-22, DisplayedOutsideTemp in older firmware
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/OutsideTemp/get?from=1");
IF response.IsSuccess
  VAR v := PARSEJSON(response.Content, "data.fields.value", true);
  IF !ISNULL(v)
    RETURN(v);
  END
END
response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/DisplayedOutsideTemp/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Termostat zone 1 Termostat Čitanje i pisanje

Sobna temperatura i aktivna zadana vrijednost zone 1; nova zadana vrijednost šalje se kao quick veto — privremena promjena, vremenski program ostaje kakav jest

numeric Jedinica: °C
Varijabla: QuickVetoHours

Termostat zone 1

Čitanje temperature
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1RoomTemp/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Čitanje željene temperature
# Z1TempDesired in the ebusd definitions micro-ebusd uses since firmware 2026-04-22, Z1ActualRoomTempDesired in older firmware
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1TempDesired/get?from=1");
IF response.IsSuccess
  VAR v := PARSEJSON(response.Content, "data.fields.value", true);
  IF !ISNULL(v)
    RETURN(v);
  END
END
response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1ActualRoomTempDesired/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Zapis željene temperature
# Quick veto: the VRC 720 starts it only when the duration is written after the temperature.
# QuickVetoHours (0.5 to 12 h in steps of 0.5) sets how long the setpoint holds; then the time programme takes over again.
VAR hours := MAX(0.5, MIN(12, ROUND(QuickVetoHours * 2) / 2));
VAR body := "{\"fields\":{\"value\":" + Se + "}}";
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1QuickVetoTemp/set", "PUT", body, "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1QuickVetoDuration/set", "PUT", "{\"fields\":{\"value\":" + hours + "}}", "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1QuickVetoTemp/get?from=2");
Način rada zone 1 Prekidač s više vrijednosti Čitanje i pisanje

Način rada zone 1 — Isključeno, Auto (vremenski program), Ručno / Dan ili Noć; na VRC 720 način day je ručni način, a noćnog načina nema

enum numeric
Vrijednosti / stanja: Isključeno · Auto · Ručno / Dan · Noć

Način rada zone 1

Čitanje stanja sklopke
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1OpMode/get?from=1");
IF response.IsSuccess
  # micro-ebusd returns the name of the value from the ebusd definition (off, auto, day, night or off, auto, manual); a number is accepted too
  VAR v := TOSTRING(PARSEJSON(response.Content, "data.fields.value", true));
  IF v = "off" OR v = "0"
    RETURN(0);
  END
  IF v = "auto" OR v = "1"
    RETURN(1);
  END
  IF v = "day" OR v = "manual" OR v = "2"
    RETURN(2);
  END
  IF v = "night" OR v = "3"
    RETURN(3);
  END
END
RETURN(NaN);
Zapis stanja sklopke
# Names from the ebusd definition the adapter answers with: off, auto, day, night in micro-ebusd firmware before
# 2026-04-22, off, auto, manual (no night) since then. The value list comes with every answer (fields[].values).
VAR def := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1OpMode/get?from=1");
VAR older := false;
IF def.IsSuccess
  older := INDEXOF(def.Content, "\"night\"") >= 0 OR INDEXOF(def.Content, "\"day\"") >= 0;
END
VAR name := SWITCH(Mu, 0, "off", 1, "auto", 2, IF(older, "day", "manual"), 3, IF(older, "night", ""), "");
IF name != ""
  SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1OpMode/set", "PUT", "{\"fields\":{\"value\":\"" + name + "\"}}", "Content-Type: application/json");
  # Read back from the bus: a write the controller ignored shows the real mode at the next read
  SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1OpMode/get?from=2");
END
Termostat potrošne tople vode Termostat Čitanje i pisanje

Temperatura spremnika tople vode i zadana temperatura tople vode, podesiva od 35 do 75 °C

numeric Jedinica: °C

Termostat potrošne tople vode

Čitanje temperature
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcStorageTemp/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Čitanje željene temperature
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcTempDesired/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Zapis željene temperature
VAR body := "{\"fields\":{\"value\":" + Se + "}}";
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcTempDesired/set", "PUT", body, "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcTempDesired/get?from=2");
Način rada potrošne tople vode Prekidač s više vrijednosti Čitanje i pisanje

Način rada kruga tople vode — Isključeno, Auto, Dan ili Noć

enum numeric
Vrijednosti / stanja: Isključeno · Auto · Dan · Noć

Način rada potrošne tople vode

Čitanje stanja sklopke
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcOpMode/get?from=1");
IF response.IsSuccess
  # micro-ebusd returns the name of the value from the ebusd definition (off, auto, day, night or off, auto, manual); a number is accepted too
  VAR v := TOSTRING(PARSEJSON(response.Content, "data.fields.value", true));
  IF v = "off" OR v = "0"
    RETURN(0);
  END
  IF v = "auto" OR v = "1"
    RETURN(1);
  END
  IF v = "day" OR v = "manual" OR v = "2"
    RETURN(2);
  END
  IF v = "night" OR v = "3"
    RETURN(3);
  END
END
RETURN(NaN);
Zapis stanja sklopke
# Names from the ebusd definition the adapter answers with: off, auto, day, night in micro-ebusd firmware before
# 2026-04-22, off, auto, manual (no night) since then. The value list comes with every answer (fields[].values).
VAR def := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcOpMode/get?from=1");
VAR older := false;
IF def.IsSuccess
  older := INDEXOF(def.Content, "\"night\"") >= 0 OR INDEXOF(def.Content, "\"day\"") >= 0;
END
VAR name := SWITCH(Mu, 0, "off", 1, "auto", 2, IF(older, "day", "manual"), 3, IF(older, "night", ""), "");
IF name != ""
  SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcOpMode/set", "PUT", "{\"fields\":{\"value\":\"" + name + "\"}}", "Content-Type: application/json");
  # Read back from the bus: a write the controller ignored shows the real mode at the next read
  SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcOpMode/get?from=2");
END
Jednokratno zagrijavanje tople vode Sklopka Čitanje i pisanje

Jednokratno zagrijavanje tople vode — uključivanje pokreće zagrijavanje, a kad se spremnik zagrije, regulator se sam vraća na auto

boolean
Vrijednosti / stanja: Active · OFF

Jednokratno zagrijavanje tople vode

Čitanje stanja sklopke
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcSFMode/get?from=1");
IF response.IsSuccess
  VAR v := TOSTRING(PARSEJSON(response.Content, "data.fields.value", true));
  IF v = "load" OR v = "6"
    RETURN(1);
  END
  RETURN(0);
END
RETURN(NaN);
Zapis stanja sklopke
# load = one-time hot water charge; the controller returns to auto by itself when the tank is charged
VAR name := IF(St, "load", "auto");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcSFMode/set", "PUT", "{\"fields\":{\"value\":\"" + name + "\"}}", "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/HwcSFMode/get?from=2");
Temperatura polaza Senzor temperature Samo za čitanje

Temperatura polaza sustava (polaz grijanja) kako je javlja regulator VRC 720

numeric Jedinica: °C

Temperatura polaza

Čitanje temperature
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/SystemFlowTemp/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Tlak vode Varijabla Samo za čitanje

Tlak vode u sustavu grijanja u barima

numeric Jedinica: bar

Tlak vode

Čitanje
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/WaterPressure/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Brojilo električne energije dizalice topline Varijabla Samo za čitanje

Električna snaga (kW) i ukupna potrošnja električne energije (kWh) uređaja aroTHERM plus; faktor učinkovitosti, toplinski prinos i stanje dizalice topline kao servisni atributi

numeric Jedinica: kW / kWh

Brojilo električne energije dizalice topline

Čitanje
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1HeatCurve/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Zapis
# Heating curve of heating circuit 1 (VRC 720: 0.1 to 4.0). The controller keeps its own limits; the read-back shows
# the value it accepted.
VAR v := ROUND(MAX(0.1, MIN(4, Va)) * 100) / 100;
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1HeatCurve/set", "PUT", "{\"fields\":{\"value\":" + v + "}}", "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1HeatCurve/get?from=2");
Hot Water Charge Hysteresis Varijabla

Hot Water Charge Hysteresis

Čitanje
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/CylinderChargeHyst/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Zapis
# Hysteresis of the hot water cylinder charge in K. The controller rejects a value outside its range; the read-back
# shows the value it kept.
VAR v := Va;
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/CylinderChargeHyst/set", "PUT", "{\"fields\":{\"value\":" + v + "}}", "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/CylinderChargeHyst/get?from=2");
Cooling Minimum Flow Temperature Varijabla

Cooling Minimum Flow Temperature

Čitanje
# Hc1CoolingFlowTempMin in the ebusd definitions micro-ebusd uses since firmware 2026-04-22, Hc1MinCoolingTempDesired in
# older firmware. The newer definitions offer it only when cooling is enabled for heating circuit 1.
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1CoolingFlowTempMin/get?from=1");
IF response.IsSuccess
  VAR v := PARSEJSON(response.Content, "data.fields.value", true);
  IF !ISNULL(v)
    RETURN(v);
  END
END
response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1MinCoolingTempDesired/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Zapis
# Lowest flow water temperature in cooling (VRC 720: 7 to 24 °C); the dew point monitoring of the controller can raise it.
VAR probe := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1CoolingFlowTempMin/get?from=1");
VAR name := IF(probe.IsSuccess, "Hc1CoolingFlowTempMin", "Hc1MinCoolingTempDesired");
VAR v := MAX(7, MIN(24, Va));
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/" + name + "/set", "PUT", "{\"fields\":{\"value\":" + v + "}}", "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/" + name + "/get?from=2");
Heating Minimum Flow Temperature Varijabla

Heating Minimum Flow Temperature

Čitanje
# Hc1HeatingFlowTempMin in the VRC 720 definitions micro-ebusd uses since firmware 2026-04-22, Hc1MinFlowTempDesired in
# older firmware and on the VRC 700.
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1HeatingFlowTempMin/get?from=1");
IF response.IsSuccess
  VAR v := PARSEJSON(response.Content, "data.fields.value", true);
  IF !ISNULL(v)
    RETURN(v);
  END
END
response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1MinFlowTempDesired/get?from=1");
IF response.IsSuccess
  RETURN(PARSEJSON(response.Content, "data.fields.value", true));
END
RETURN(NaN);
Zapis
# Lowest flow water temperature in heating. The controller heats to the higher of its heating curve and this value, so with
# a low heating curve the value written here is the flow water temperature (for example from the Equithermic regulation smart
# rule); the maximum flow temperature of the controller still caps it. The controller keeps the value in its permanent memory:
# the value is rounded to a whole degree and written only when it changes.
VAR probe := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Hc1HeatingFlowTempMin/get?from=1");
VAR name := IF(probe.IsSuccess, "Hc1HeatingFlowTempMin", "Hc1MinFlowTempDesired");
VAR v := MAX(15, MIN(80, ROUND(Va)));
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/" + name + "/set", "PUT", "{\"fields\":{\"value\":" + v + "}}", "Content-Type: application/json");
SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/" + name + "/get?from=2");
Zone 1 Cooling Mode Prekidač s više vrijednosti
Vrijednosti / stanja: Off · Auto · Manual

Zone 1 Cooling Mode

Čitanje stanja sklopke
# Z1CoolingOpMode in the VRC 720 definitions micro-ebusd uses since firmware 2026-04-22, only when cooling is enabled for
# heating circuit 1; Z1OpModeCooling (off, auto, day, night) on the VRC 700. Older VRC 720 firmware has neither: no value.
VAR response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1CoolingOpMode/get?from=1");
IF !response.IsSuccess
  response := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1OpModeCooling/get?from=1");
END
IF response.IsSuccess
  VAR v := TOSTRING(PARSEJSON(response.Content, "data.fields.value", true));
  IF v = "off" OR v = "0"
    RETURN(0);
  END
  IF v = "auto" OR v = "1"
    RETURN(1);
  END
  IF v = "manual" OR v = "day" OR v = "2"
    RETURN(2);
  END
END
RETURN(NaN);
Zapis stanja sklopke
# VRC 720: Z1CoolingOpMode off, auto, manual. VRC 700: Z1OpModeCooling off, auto, day (Manual = day).
VAR probe := SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/Z1CoolingOpMode/get?from=1");
VAR msg := IF(probe.IsSuccess, "Z1CoolingOpMode", "Z1OpModeCooling");
VAR name := SWITCH(Mu, 0, "off", 1, "auto", 2, IF(probe.IsSuccess, "manual", "day"), "");
IF name != ""
  SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/" + msg + "/set", "PUT", "{\"fields\":{\"value\":\"" + name + "\"}}", "Content-Type: application/json");
  # Read back from the bus: a write the controller ignored shows the real mode at the next read
  SENDHTTPREQUEST("/api/v1/ebus/" + "$[CONTROLLER_CIRCUIT]" + "/" + msg + "/get?from=2");
END
Povezivanje: Packet Parser → HTTP
Moguća poboljšanja (5)
  • Cooling of zone 1 — The controller definition has cooling setpoints for the zone and the heating circuit; the template covers heating only.
  • Installer parameters (heat curve, maximum flow temperature) — Left out on purpose — installer settings of the controller are not changed from TapHome.
  • Weekly time programme — Reading and editing the weekly schedule of the zone and the hot water is not part of the template.
  • Further heat pump values — Air intake temperature, compressor utilisation and current heat output of the outdoor unit.
  • Further zones — The template covers zone 1 only.

Parametri uvoza

Ove vrijednosti unosite pri uvozu XML-a.

Pitanje u aplikacijiZadano
eBUS Adapter IP AddressUnosi se pri uvozu
Controller circuit name (e.g. ctlv2 for VRC 720, 700 for VRC 700)ctlv2
Heat source circuit name (e.g. hmu for aroTHERM plus)hmu

Izvori

  • micro-ebusd HTTP JSON API (get, set, list, from=0/1/2, token)
    token.ebusd.eu 2026-11-04
  • ebusd message definitions — Vaillant sensoCOMFORT VRC 720 (15.ctlv2.csv)
    ebus.github.io 2026-11-04
  • ebusd message definitions — Vaillant aroTHERM plus outdoor unit (08.hmu.csv)
    ebus.github.io 2026-11-04
  • ebusd configuration — Vaillant index
    ebus.github.io 2026-11-04
  • micro-ebusd MQTT documentation
    token.ebusd.eu 2026-11-04
  • aroTHERM plus and VRC 720 with ebusd — community integration (R91g/arotherm-genia-ebusd)
    github.com 2026-11-04

Pronašli ste problem s ovim predloškom uređaja?

Recite nam što ne radi, što nedostaje ili kako bi se predložak trebao ponašati. Vaše povratne informacije pomažu nam da katalog bude točan.

Predložak · TapHome portal Vaillant aroTHERM plus + sensoCOMFORT VRC 720 / multiMATIC VRC 700 (eBUS, micro-ebusd) Otvorite ovaj predložak na portalu Customer Portal kako biste ga primijenili na jedan od svojih domova ili predložili poboljšanje i poslali ga natrag u katalog. Packet Parser → HTTP Pogledaj u TapHome portalu