  questions: ["Ako integrovať Kostal PLENTICORE s TapHome?","Čo sleduje a ovláda šablóna Kostal PLENTICORE v TapHome?","Ako pripojiť Kostal PIKO IQ cez Modbus TCP k TapHome?","Ako nastaviť limity SOC batérie na Kostal PLENTICORE cez TapHome?","Prečo striedač Kostal používa TCP port 1502 namiesto 502?","Aké dáta FV stringov sú dostupné z Kostal PLENTICORE v TapHome?"]
---

# Kostal PLENTICORE plus

Komunikácia: Modbus TCP

- [Oficiálna stránka Kostal Solar Electric](https://www.kostal-solar-electric.com)

> Adresa v sieti
> 
> TapHome komunikuje so zariadením na adrese zadanej pri importe. Dajte zariadeniu stálu adresu — rezerváciu IP v routeri, alebo jeho mDNS meno, ak ho podporuje —, inak integrácia prestane fungovať, keď router adresu zmení.
> 
> [Príprava siete](https://taphome.com/sk/docs/setup/network-preparation/)

## Návod na integráciu

Séria Kostal PIKO IQ a PLENTICORE plus sú hybridné solárne striedače s až troma MPPT trackermi a voliteľným batériovým úložiskom. TapHome sa pripája priamo k striedaču cez Modbus TCP po sieti Ethernet. Šablóna pokrýva modely PIKO IQ, PLENTICORE G1, G2, G3 a PLENTICORE MP G3 vo výkonových triedach od 3 kW do 10 kW.

Šablóna poskytuje monitorovanie FV stringov (výkon, prúd, napätie pre každý DC vstup), stav nabitia batérie s nastaviteľnými min/max limitmi, štatistiky výnosu (denné, mesačné, ročné, celkové), výkon AC výstupu a diagnostiku striedača.

## Sieťové pripojenie

Striedač má RJ45 port Ethernet na Smart Communication Board. Pripojte ho do rovnakej lokálnej siete ako TapHome Core pomocou štandardného ethernetového kábla.

- **Protokol:** Modbus TCP
- **Port:** 1502 (neštandardný -- odlišný od štandardného Modbus TCP portu 502)
- **Predvolené Unit-ID:** 71
- **Poradie bajtov:** Big-endian ABCD, ktoré táto šablóna vyžaduje (predvolené nastavenie striedača je Little-endian CDAB)

> [!WARNING]
> Striedač Kostal používa TCP port **1502**, nie štandardný Modbus port 502. Skontrolujte, že je to správne nakonfigurované v TapHome počas importu šablóny. Predvolené Unit-ID je **71** (parameter šablóny TapHome je predvolene 1 -- nastavte na 71, aby zodpovedalo továrensky nastavenej hodnote).

## Konfigurácia

### Aktivácia komunikácie Modbus TCP

Modbus TCP musí byť na striedači explicitne zapnutý, aby s ním TapHome mohlo komunikovať:

1. Otvorte webové rozhranie striedača (zadajte IP adresu striedača do prehliadača)
2. Prejdite na **Nastavenia > Modbus/SunSpec (TCP)**
3. Zapnite **Modbus TCP**
4. Nastavte poradie bajtov na **Big-endian (ABCD)** -- táto šablóna číta hodnoty Float v poradí ABCD, takže pri predvolenom Little-endian (CDAB) sú hodnoty nezmyselné. Ak chcete ponechať predvolené nastavenie, použite namiesto nej šablónu [Kostal PLENTICORE plus](https://taphome.com/sk/compatibility/kostalplenticore/)
5. Zaznamenajte si **Unit-ID** (predvolene 71) a **TCP port** (predvolene 1502)

Pri importe šablóny v TapHome zadajte:

- **IP adresa** -- IP adresa striedača v lokálnej sieti
- **Slave ID** -- nastavte na **71** (zodpovedá Unit-ID striedača)

## Možnosti zariadenia

### Monitorovanie FV stringov

Tri senzory FV stringov (DC1, DC2, DC3) každý hlási:

- **Výkon** (kW) -- okamžitý výstup z MPPT trackera
- **Prúd** (A) a **Napätie** (V) -- dostupné ako servisné atribúty každého výkonového zariadenia

DC3 je možné voliteľne použiť na pripojenie batérie namiesto tretieho FV stringu, v závislosti od modelu striedača a inštalácie.

- **Celkový DC výkon** -- kombinovaný výstup zo všetkých pripojených FV stringov (register H:1066)
- **Celkový aktívny AC výkon** -- celkový výkon dodávaný do AC siete (register H:172)

### Správa batérie

- **SOC batérie** -- aktuálny stav nabitia (0--100 %). Šablóna tiež sprístupňuje napätie batérie, teplotu a typ batérie ako servisné atribúty.
- **Nastavenia SOC (servisná akcia)** -- nakonfigurujte minimálny SOC (1--90 %) a maximálny SOC (10--100 %) priamo z TapHome. Tým sa riadi, ako hlboko sa batéria vybíja a ako úplne sa nabíja.

| Servisný atribút | Popis |
|------------------|-------|
| Napätie batérie | Aktuálne napätie batérie (V) |
| Teplota batérie | Aktuálna teplota batérie (C) |
| Minimálny SOC | Nastavený dolný limit SOC (%) |
| Maximálny SOC | Nastavený horný limit SOC (%) |
| Typ batérie | Pripojená batéria (BYD, LG, BMZ, Pyontech, Dyness, VARTA a ďalšie) |

### Štatistiky výnosu

Štyri energetické počítadlá sledujú výrobu FV v rôznych časových obdobiach:

| Zariadenie | Popis |
|------------|-------|
| Denný výnos | Energia vyrobená dnes (kWh) |
| Mesačný výnos | Energia vyrobená tento mesiac (kWh) |
| Ročný výnos | Energia vyrobená tento rok (kWh) |
| Celkový výnos | Kumulatívna energia od inštalácie (kWh) |

Všetky hodnoty výnosu sa čítajú zo striedača vo Wh a šablóna ich prevádza na kWh.

### Diagnostika striedača

Servisné atribúty na úrovni modulu poskytujú stav systému:

| Servisný atribút | Popis |
|------------------|-------|
| Stav striedača | Aktuálny prevádzkový stav (Vypnutý, Init, FeedIn, Throttled, Standby, Prehrievanie, Vypínanie a ďalšie -- celkovo 19 stavov) |
| Frekvencia siete | Frekvencia AC siete (Hz) |
| MODBUS Enable | Či je komunikácia Modbus TCP aktívna |
| IP Enable | Či je sieťové IP pripojenie zapnuté |

### Ďalšie možnosti

Kostal PLENTICORE tiež sprístupňuje Modbus registre pre monitorovanie AC výkonu po fázach, rozklad domácej spotreby (z FV, batérie a siete), dáta cyklov nabíjania/vybíjania batérie, merania externého wattmetra a riadenie obmedzenia aktívneho výkonu. K dispozícii sú aj podrobné energetické počítadlá batérie (DC nabíjanie/vybíjanie, AC nabíjanie/vybíjanie, export do siete) a prepínané výstupy I/O dosky. Tieto je možné pridať do šablóny TapHome v budúcej aktualizácii.

## Riešenie problémov

### Žiadna komunikácia Modbus

1. Overte, že Modbus TCP je zapnutý vo webovom rozhraní striedača v časti **Nastavenia > Modbus/SunSpec (TCP)**
2. Skontrolujte, že TCP port je **1502** (nie štandardný 502)
3. Overte, že Unit-ID zodpovedá striedaču (predvolene 71) a konfigurácii šablóny TapHome
4. Skontrolujte, že poradie bajtov na striedači zodpovedá šablóne: **Big-endian (ABCD)**
5. Skontrolujte, že TapHome Core a striedač sú v rovnakej sieti/podsieti

### Nesprávne hodnoty alebo nulové hodnoty

- Striedač hlási nulové hodnoty výkonu, keď nevyrába (noc, striedač vypnutý). Toto je normálne správanie.
- Ak sa hodnoty javia ako nesprávne, skontrolujte nastavenie poradia bajtov -- táto šablóna očakáva Big-endian (ABCD); predvolené Little-endian (CDAB) produkuje nesprávne hodnoty Float.

### SOC batérie sa neaktualizuje

- Overte, že je pripojená a rozpoznaná kompatibilná batéria (skontrolujte servisný atribút Typ batérie)
- Ak Typ batérie zobrazuje "No battery (PV-functionality)", striedač pracuje v režime len FV bez batériového úložiska

## Dostupné zariadenia 10

Tieto zariadenia sa po importe zobrazia v TapHome.

PlentyCore Modul

Servisné atribúty

|                  |                                                                                                                             |
|------------------|-----------------------------------------------------------------------------------------------------------------------------|
| MODBUS enable    | Či je komunikácia Modbus TCP zapnutá na striedači                                                                           |
| IP enable        | Či je sieťové IP pripojenie zapnuté na striedači                                                                            |
| Frekvencia siete |                                                                                                                             |
| Stav striedača   | Aktuálny prevádzkový stav — Vypnutý, Init, FeedIn, Throttled, Standby, Prehrievanie, Vypínanie a ďalšie (celkovo 19 stavov) |

Servisné atribúty

MODBUS enable

```taphome
IF(MODBUSR(H, 2, Bool), "Enabled", "Disabled");
```

IP enable

```taphome
IF(MODBUSR(H, 416, Bool), "Enabled", "Disabled");
```

Grid Frequency

```taphome
ROUND(MODBUSR(H, 152, Float, 2)) + " Hz";
```

Inverter State

```taphome
SWITCH(MODBUSR(H, 56, Uint16), 
0, "Off",
1, "Init",
2, "IsoMeas",
3, "GridCheck",
4, "StartUp",
5, "-",
6, "FeedIn",
7, "Throttled",
8, "ExtSwitchOff",
9, "Update",
10, "Standby",
11, "GridSync",
12, "GridPreCheck",
13, "GridSwitchOff",
14, "Overheating",
15, "Shutdown",
16, "ImproperDcVoltage",
17, "ESB",
18, "Unknown",
"Error"
);
```

SOC batérie Analógový vstup Len na čítanie

Stav nabitia batérie (0–100 %) s napätím, teplotou a nastaviteľnými min/max limitmi SOC

Register: H:210 Float Jednotka: %

Servisné atribúty

|                 |                                                                                        |
|-----------------|----------------------------------------------------------------------------------------|
| Napätie batérie |                                                                                        |
| Teplota batérie |                                                                                        |
| Minimálny SOC   | Nastavený dolný limit stavu nabitia (1–90 %)                                           |
| Maximálny SOC   | Nastavený horný limit stavu nabitia (10–100 %)                                         |
| Typ batérie     | Pripojená batéria — No battery, PIKO Battery Li, BYD, BMZ, LG, Pyontech, Dyness, VARTA |

Servisné akcie

|                |                                                                   |
|----------------|-------------------------------------------------------------------|
| Nastavenia SOC | Nastavenie minimálneho a maximálneho limitu stavu nabitia batérie |

Čítanie vstupnej úrovne

```taphome
MODBUSR(H, 210, Float, 2)/100
```

Servisné atribúty

Battery Voltage

```taphome
ROUND(MODBUSR(H, 216, Float, 2)) + " V";
```

Battery Temperature

```taphome
MODBUSR(H, 214, Float, 2) + " °C"
```

Minimum SOC

```taphome
MODBUSR(H, 1042, Float, 2) + "%"
```

Maximum SOC

```taphome
MODBUSR(H, 1044, Float, 2) + "%"
```

Battery Type

```taphome
SWITCH(MODBUSR(H, 588, Uint16),
 0, "No battery (PV-functionality)",
 2, "Li-Io battery SONY / MURATA",
 4, "Li-Io battery BYD / BBOX",
 "Unknown"
 );
```

Servisné akcie

SOC settings

Parametre: Minimum SOC (1–90 mis), Maximum SOC (10–100 mas)

```taphome
MODBUSW(H, 1042, Float, mis,  2);
MODBUSW(H, 1044, Float, mas, 2);

```

Denný výnos Premenná Len na čítanie

Energia vyrobená dnes (Wh prevedené na kWh)

Register: H:322 Float Jednotka: kWh

Čítanie

```taphome
MODBUSR(H, 322, Float, 2)/1000
```

Mesačný výnos Premenná Len na čítanie

Energia vyrobená tento mesiac (Wh prevedené na kWh)

Register: H:326 Float Jednotka: kWh

Čítanie

```taphome
MODBUSR(H, 326, Float, 2)/1000
```

Výkon DC1 Premenná Len na čítanie

Výstupný výkon FV stringu 1 (MPPT 1) (W prevedené na kW)

Register: H:260 Float Jednotka: kW

Servisné atribúty

|             |
|-------------|
| Prúd DC1    |
| Napätie DC1 |

Čítanie

```taphome
MODBUSR(H, 260, float, 2)/1000
```

Servisné atribúty

Current DC1

```taphome
ROUND(MODBUSR(H, 258, Float, 2)) + " A";
```

Voltage DC1

```taphome
ROUND(MODBUSR(H, 266, Float, 2)) + " V"
```

Výkon DC2 Premenná Len na čítanie

Výstupný výkon FV stringu 2 (MPPT 2) (W prevedené na kW)

Register: H:270 Float Jednotka: kW

Servisné atribúty

|             |
|-------------|
| Prúd DC2    |
| Napätie DC2 |

Čítanie

```taphome
MODBUSR(H, 270, float, 2)/1000
```

Servisné atribúty

Current DC2

```taphome
ROUND(MODBUSR(H, 268, Float, 2)) + " A";
```

Voltage DC2

```taphome
ROUND(MODBUSR(H, 276, Float, 2)) + " V"
```

Výkon DC3 Premenná Len na čítanie

Výstupný výkon FV stringu 3 (MPPT 3) — možno voliteľne použiť na pripojenie batérie

Register: H:280 Float Jednotka: kW

Servisné atribúty

|             |
|-------------|
| Prúd DC3    |
| Napätie DC3 |

Čítanie

```taphome
MODBUSR(H, 280, float, 2)/1000
```

Servisné atribúty

Current DC3

```taphome
ROUND(MODBUSR(H, 278, Float, 2)) + " A";
```

Voltage DC3

```taphome
ROUND(MODBUSR(H, 286, Float, 2)) + " V"
```

Celkový aktívny AC výkon Premenná Len na čítanie

Celkový aktívny výkon na strane AC siete (W prevedené na kW)

Register: H:172 Float Jednotka: kW

Čítanie

```taphome
MODBUSR(H, 172, Float, 2)/1000
```

Celkový DC výkon Premenná Len na čítanie

Kombinovaný výstup zo všetkých pripojených FV stringov (W prevedené na kW)

Register: H:1066 Float Jednotka: kW

Čítanie

```taphome
MODBUSR(H, 1066, Float, 2)/1000
```

Celkový výnos Premenná Len na čítanie

Kumulatívna celková energia vyrobená od inštalácie (Wh prevedené na kWh)

Register: H:320 Float Jednotka: kWh

Čítanie

```taphome
MODBUSR(H, 320, Float, 2)/1000
```

Ročný výnos Premenná Len na čítanie

Energia vyrobená tento rok (Wh prevedené na kWh)

Register: H:324 Float Jednotka: kWh

Čítanie

```taphome
MODBUSR(H, 324, Float, 2) /1000
```

**Pripojenie:** Modbus TCP • Slave ID: $\[SlaveId]

Možné vylepšenia (22)

- H:98 Controller PCB Temperature — Float, °C, read-only — inverter internal temperature
- H:100 Total DC Power (addr 100) — Float, W — alternative register for total DC power (template uses H:1066 instead, which is sum of all PV inputs)
- H:106 Home Own Consumption from Battery — Float, W, read-only
- H:108 Home Own Consumption from Grid — Float, W, read-only
- H:116 Home Own Consumption from PV — Float, W, read-only
- H:118 Total Home Consumption — Float, Wh, read-only — cumulative
- H:156 Active Power Phase 1 — Float, W, read-only
- H:162 Active Power Phase 2 — Float, W, read-only
- H:170 Active Power Phase 3 — Float, W, read-only
- H:194 Number of Battery Cycles — Float, read-only — battery health indicator
- H:200 Actual Battery Charge/Discharge Current — Float, A, read-only — negative=charge, positive=discharge
- H:252 Total Active Power (Powermeter) — Float, W, read-only — external power meter reading
- H:512 Battery Gross Capacity — U32, Ah, read-only
- H:1046 Total DC Charge Energy (DC-side to Battery) — Float, Wh, read-only
- H:1048 Total DC Discharge Energy (DC-side from Battery) — Float, Wh, read-only
- H:1056 Total DC PV Energy (sum of all PV inputs) — Float, Wh, read-only — cumulative PV production
- H:1064 Total Energy AC-side to Grid — Float, Wh, read-only — total energy exported
- H:1068 Battery Work Capacity — Float, Wh, read-only
- H:1076 Maximum Charge Power (from battery) — Float, W, read-only — battery-reported charge limit
- H:1078 Maximum Discharge Power (from battery) — Float, W, read-only — battery-reported discharge limit
- H:533 Active Power Setpoint — U16, %, write-only — power curtailment (1-100%)
- H:608-611 I/O Board Switched Outputs 1-4 — U16, R/W — digital outputs for external relay control

## Parametre importu

Tieto hodnoty zadáte pri importe XML.

| Pýta sa v aplikácii | Predvolené    |
|---------------------|---------------|
| Slave ID            | `1`           |
| IP adresa           | `192.168.1.0` |

## Zdroje

- KOSTAL Modbus TCP Interface Description v2.7
  
  [www.kostal-solar-electric.com](https://www.kostal-solar-electric.com/fileadmin/downloadcenter/kse/BA/Protokollbeschreibung/BA_KOSTAL_Interface_MODBUS-TCP_SunSpec_with_Control.pdf) 2026-03-27
  
  [PDF](https://taphome.com/compatibility/devices/plentycoreinverter/manufacturer/kostal-modbus-interface.pdf)
- HA Kostal Plenticore Modbus Integration
  
  [github.com](https://github.com/CrunkA3/ha_kostal_plenticore_modbus) 2026-03-27

Dokumenty výrobcov sú © ich príslušných vlastníkov. Poskytujeme ich tak, ako ich zverejnil výrobca, len na informačné účely.

## Súvisiaca dokumentácia

- [Modbus Integration](https://taphome.com/sk/compatibility/modbus-guide/)
- [Modbus](https://taphome.com/sk/docs/integration/modbus/)
- [Jednoduchá konfigurácia pomocou šablón](https://taphome.com/sk/docs/integration/modbus/templates/)
- [Skripty Modbus a prefetch](https://taphome.com/sk/docs/script/modbus-scripts/)
- [Funkcie Modbus](https://taphome.com/sk/docs/script/modbus/)
- [Dátové typy Modbus](https://taphome.com/sk/docs/script/modbus-data-types/)