  questions: ["Cum integrez invertorul Sofar Solar HYD KTL-3PH cu TapHome?","Ce monitorizează șablonul TapHome pentru Sofar Solar HYD KTL-3PH?","Cum conectez Sofar Solar HYD KTL-3PH la TapHome prin RS-485?","Cum conectez mai multe invertoare Sofar Solar pe o singură magistrală RS-485?","Ce parametri ai bateriei citește șablonul TapHome pentru Sofar Solar?","Cum monitorizez cu TapHome producția PV și energia din rețea?"]
---

# Sofar Solar HYD KTL-3PH

Comunicație: Modbus RTU

- [Site-ul oficial Sofar Solar](https://www.sofarsolar.com)

## Ghid de integrare

Sofar Solar HYD 5/6/8/10/15/20KTL-3PH este o serie de invertoare solare hibride trifazate, care combină producția fotovoltaică cu stocarea energiei în baterii. TapHome se conectează prin Modbus RTU pe RS-485, prin portul COM cu 16 pini al invertorului, și citește registrele holding pentru puterea PV în timp real, starea bateriei, puterea din rețea, tensiunile pe fiecare fază și contoarele de energie.

Invertorul acceptă până la 31 de dispozitive pe o singură magistrală RS-485 cu cablare în lanț (daisy chain). Fiecare invertor necesită un Slave ID Modbus unic (configurabil, implicit 1). Parametrii de comunicație sunt ficși: 9600 baud, 8N1.

## Conectarea hardware

### Interfețele de comunicație

![Amplasarea interfețelor de comunicație ale Sofar Solar HYD KTL-3PH](https://taphome.com/images/compatibility/sofarsolar-inverter-3p/communication-interfaces_hu_5a569478a95349ec.jpg)

Conexiunea RS-485 pentru monitorizarea din TapHome folosește **portul COM** — un conector multifuncțional cu 16 pini, aflat în partea de jos a invertorului.

### Configurația pinilor portului COM

![Configurația pinilor conectorului COM cu 16 pini al Sofar Solar HYD KTL-3PH](https://taphome.com/images/compatibility/sofarsolar-inverter-3p/com-port-pinout_hu_1534b25dbbb0b858.jpg)

**Pinii relevanți pentru conectarea la TapHome:**

| Pin | Funcție | Notă |
|-----|----------|------|
| **1** | RS485A1-1 (+) | Semnalul A RS-485 pentru monitorizare/control |
| **2** | RS485A1-2 (+) | Al doilea conector pentru cablarea în lanț |
| **3** | RS485B1-1 (-) | Semnalul B RS-485 |
| **4** | RS485B1-2 (-) | Al doilea conector pentru cablarea în lanț |
| 5 | RS485A2 (+) | Contor inteligent — magistrală separată |
| 6 | RS485B2 (-) | Contor inteligent — magistrală separată |
| 7 | CAN0_H | Comunicația BMS (CAN) |
| 8 | CAN0_L | Comunicația BMS (CAN) |

Conectați TapHome la **pinii 1+3** (sau 2+4):
- **Pinul 1 (RS485A1)** → A+/D+ pe RS-485 TapHome
- **Pinul 3 (RS485B1)** → B-/D- pe RS-485 TapHome

> [!WARNING]
> **Nu folosiți pinii 5+6** — aceștia sunt dedicați contorului inteligent, pe o magistrală RS-485 separată. Pentru monitorizarea Modbus, TapHome trebuie conectat la pinii 1+3 (sau 2+4).

### Cablarea RS-485 în lanț (daisy chain)

![Cablarea RS-485 în lanț a mai multor invertoare Sofar Solar](https://taphome.com/images/compatibility/sofarsolar-inverter-3p/wiring-rs485-daisy-chain_hu_1365fa6dd95340c6.jpg)

Când conectați mai multe invertoare, legați-le în lanț pe magistrala RS-485. Montați un **rezistor de terminație de 120 Ω** între pinul 1 și pinul 4 la primul și la ultimul dispozitiv de pe magistrală.

**Specificația cablului:**
- Tip: pereche torsadată ecranată, secțiunea conductorului de cupru > 0,5 mm²
- Lungime maximă: **1200 m**
- Păstrați cablurile departe de cablurile de forță și de câmpurile electrice

## Configurare

### Parametrii de comunicație Modbus

Parametrii de comunicație RS-485 sunt ficși și nu necesită configurare pe invertor:

| Parametru | Valoare |
|-----------|-------|
| Viteză de transmisie (baud rate) | 9600 bps |
| Biți de date | 8 |
| Paritate | Fără |
| Biți de stop | 1 |
| Slave ID | 1 (implicit, configurabil 1–31) |

Pentru mai multe invertoare pe aceeași magistrală, fiecare invertor trebuie să aibă un Slave ID unic. Slave ID-ul se poate configura din meniul LCD al invertorului sau din aplicația SolarMAN.

## Funcțiile dispozitivului

### Monitorizarea bateriei

Șablonul oferă monitorizarea stării de încărcare pentru până la două pachete de baterii. SOC baterie 1 este disponibil la toate modelele HYD KTL-3PH, iar SOC baterie 2 la modelele HYD 10–20KTL-3PH cu două intrări pentru baterii.

Fiecare dispozitiv SOC baterie include cinci atribute de service pentru diagnosticarea detaliată a bateriei: temperatura, tensiunea, curentul de încărcare/descărcare, puterea de încărcare/descărcare și starea de sănătate (SOH).

Două dispozitive contor de energie urmăresc încărcarea și descărcarea zilnică a bateriei în kWh, fiecare cu un atribut de service pentru totalul de la punerea în funcțiune.

### Monitorizarea producției PV

Șablonul citește puterea de ieșire a până la trei stringuri PV individuale (PV1, PV2, PV3), fiecare cu atribute de service pentru tensiunea și curentul stringului. Dispozitivul combinat Putere PV totală arată puterea însumată a tuturor stringurilor.

Două dispozitive contor de energie urmăresc producția PV — totalul zilnic și cel de la punerea în funcțiune, în kWh.

### Energia din rețea și consumul sarcinilor

Trei dispozitive contor de energie oferă valori zilnice pentru schimbul cu rețeaua și consumul sarcinilor:
- **Energie cumpărată azi** — energia cumpărată din rețea (kWh)
- **Energie vândută azi** — energia vândută în rețea (kWh)
- **Consum sarcini azi** — consumul total al sarcinilor (kWh)

Fiecare contor zilnic include un atribut de service cu totalul de la punerea în funcțiune.

### Monitorizarea ieșirii AC

Șablonul oferă trei dispozitive pentru tensiunea pe fiecare fază (faza R/S/T, corespunzătoare L1/L2/L3), fiecare cu un atribut de service pentru curentul fazei. Frecvența rețelei este raportată în Hz.

Două dispozitive de putere monitorizează ieșirea invertorului în puncte de măsurare diferite:
- **Putere activă totală la ieșire** — puterea de ieșire a invertorului în kW, cu atribute de service pentru puterea reactivă (kVAR) și puterea aparentă (kVA)
- **Putere activă totală PCC** — puterea în punctul comun de cuplare (punctul de racordare la rețea), în kW, cu atribute de service pentru puterea reactivă și aparentă. Această măsurătoare se folosește pentru limitarea injecției în rețea și pentru funcțiile controlerului centralei fotovoltaice.

### Atributele de service ale modulului

Modulul oferă trei atribute de service pentru diagnosticarea invertorului:
- **Cod produs** — identificarea produsului invertorului
- **Starea sistemului** — starea de funcționare curentă: Așteptare, Detectare, Conectat la rețea, Alimentare de urgență, Defecțiune recuperabilă, Defecțiune permanentă, Actualizare sau Autoîncărcare
- **Temperatură ambiantă** — temperatura din interiorul invertorului în °C

ReadScript-ul modulului monitorizează și trei registre de defecțiuni de tip mască de biți (H:0x0405–H:0x0407) și raportează în TapHome ca erori defecțiunile protecției de rețea, erorile de eșantionare și defecțiunile hardware.

### Funcții suplimentare

Invertoarele HYD KTL-3PH oferă și registre pentru pornirea/oprirea de la distanță, selectarea modului de stocare a energiei (Self-use, Time-of-Use, Timing, Passive, Peak Shaving, Off-grid) și controlul pasiv al încărcării/descărcării bateriei pentru sisteme externe de management energetic. Prin Modbus sunt disponibile și puterea activă și factorul de putere pe fiecare fază, monitorizarea ieșirii off-grid/EPS, intrări suplimentare pentru stringuri PV (PV4+), numărul de cicluri ale bateriei, temperatura radiatorului și parametrii bateriilor 3–6. Acestea pot fi adăugate într-o actualizare viitoare a șablonului.

> [!TIP]
> Registrele modului Passive (H:0x1110 și H:0x1187) permit controlul extern prin Modbus al puterii de încărcare/descărcare a bateriei. Acest lucru este deosebit de util pentru smart rules TapHome care implementează strategii de management energetic, cum ar fi încărcarea bateriilor în perioadele cu tarif redus.

## Depanare

### Nu există comunicare Modbus

1. Verificați dacă cablul RS-485 este conectat la **pinii 1+3** (sau 2+4) ai portului COM — nu la pinii 5+6 (magistrala contorului inteligent)
2. Verificați polaritatea cablului: pinul 1 (A+) la A+ TapHome, pinul 3 (B-) la B- TapHome
3. Verificați dacă TapHome este configurat pentru 9600 baud, fără paritate, 1 bit de stop
4. Verificați dacă Slave ID-ul coincide pe invertor și în TapHome
5. Verificați rezistorul de terminație de 120 Ω la primul și la ultimul dispozitiv de pe magistrală

### Erori de comunicare intermitente

1. Asigurați-vă că cablul RS-485 este o pereche torsadată ecranată, cu secțiunea conductorului de cupru > 0,5 mm²
2. Păstrați cablurile RS-485 departe de cablurile de forță și de cablajul DC
3. Verificați ca lungimea totală a magistralei să nu depășească 1200 m
4. Verificați să nu existe Slave ID-uri duplicate pe magistrală

### Starea sistemului indică o defecțiune

1. Verificați în atributul de service Starea sistemului codul stării respective (4 = Defecțiune recuperabilă, 5 = Defecțiune permanentă)
2. Analizați detaliile registrelor de defecțiuni în diagnosticarea de service din TapHome — șablonul citește trei registre de defecțiuni de tip mască de biți, care acoperă protecția de rețea, erorile de eșantionare și defecțiunile hardware
3. Pentru codurile de eroare detaliate, consultați afișajul LCD al invertorului sau aplicația SolarMAN

## Dispozitive disponibile 19

Aceste dispozitive apar în TapHome după import.

Sofar Solar HYD KTL-3PH Modul

Atribute de service

|                      |                                                                                                                                                                                   |
|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Cod produs           |                                                                                                                                                                                   |
| Starea sistemului    | Starea de funcționare a invertorului — Așteptare, Detectare, Conectat la rețea, Alimentare de urgență, Defecțiune recuperabilă, Defecțiune permanentă, Actualizare, Autoîncărcare |
| Temperatură ambiantă | Temperatura din interiorul invertorului în °C                                                                                                                                     |

Citire (modul)

```taphome
#fault 1
var fault :=MODBUSR(H, 0x0405, Uint16);
IF fault !=0 
IF(GETBIT(fault, 0) != 0, ADDERROR("Grid over-voltage"));
IF(GETBIT(fault, 1) != 0, ADDERROR("Grid undervoltage"));
IF(GETBIT(fault, 2) != 0, ADDERROR("Grid overfrequency"));
IF(GETBIT(fault, 3) != 0, ADDERROR("Grid underfrequency"));
IF(GETBIT(fault, 4) != 0, ADDERROR("Leakage current fault"));
IF(GETBIT(fault, 5) != 0, ADDERROR("High penetration error"));
IF(GETBIT(fault, 6) != 0, ADDERROR("Low penetration error"));
IF(GETBIT(fault, 7) != 0, ADDERROR("Islanding error"));
IF(GETBIT(fault, 8) != 0, ADDERROR("Grid voltage transient value overvoltage 1"));
IF(GETBIT(fault, 9) != 0, ADDERROR("Grid voltage transient value overvoltage 2"));
IF(GETBIT(fault, 10) != 0, ADDERROR("Grid line voltage error"));
IF(GETBIT(fault, 11) != 0, ADDERROR("Inverter voltage error"));
IF(GETBIT(fault, 12) != 0, ADDERROR("Anti-backflow overload"));
END

#fault 2
fault :=MODBUSR(H, 0x0406, Uint16);
IF fault !=0 
IF(GETBIT(fault, 0) != 0, ADDERROR("Grid current sampling error"));
IF(GETBIT(fault, 1) != 0, ADDERROR("Grid current DC component sampling error (AC side)"));
IF(GETBIT(fault, 2) != 0, ADDERROR("Grid voltage sampling error (DC side)"));
IF(GETBIT(fault, 3) != 0, ADDERROR("Grid voltage sampling error (AC side)"));
IF(GETBIT(fault, 4) != 0, ADDERROR("Leakage current sampling error (DC side)"));
IF(GETBIT(fault, 5) != 0, ADDERROR("Leakage current sampling error (AC side)"));
IF(GETBIT(fault, 6) != 0, ADDERROR("Load voltage DC component sampling error"));
IF(GETBIT(fault, 7) != 0, ADDERROR("DC input current sampling error"));
IF(GETBIT(fault, 8) != 0, ADDERROR("DC component sampling error of grid current (DC side)"));
IF(GETBIT(fault, 9) != 0, ADDERROR("DC input branch current sampling error"));
IF(GETBIT(fault, 12) != 0, ADDERROR("Leakage current consistency error"));
IF(GETBIT(fault, 13) != 0, ADDERROR("Grid voltage consistency error"));
IF(GETBIT(fault, 14) != 0, ADDERROR("DCI consistency error"));
END

#fault 3
fault :=MODBUSR(H, 0x0407, Uint16);
IF fault !=0 
IF(GETBIT(fault, 0) != 0, ADDERROR("SPI communication error (DC side)"));
IF(GETBIT(fault, 1) != 0, ADDERROR("SPI communication error (AC side)"));
IF(GETBIT(fault, 2) != 0, ADDERROR("Chip error (DC side)"));
IF(GETBIT(fault, 3) != 0, ADDERROR("Chip error (AC side)"));
IF(GETBIT(fault, 4) != 0, ADDERROR("Auxiliary power error"));
IF(GETBIT(fault, 5) != 0, ADDERROR("Inverter soft start failure"));
IF(GETBIT(fault, 8) != 0, ADDERROR("Relay detection failure"));
IF(GETBIT(fault, 9) != 0, ADDERROR("Low insulation impedance"));
IF(GETBIT(fault, 10) != 0, ADDERROR("Grounding error"));
IF(GETBIT(fault, 11) != 0, ADDERROR("Input mode setting error"));
IF(GETBIT(fault, 12) != 0, ADDERROR("CT error"));
IF(GETBIT(fault, 13) != 0, ADDERROR("Input reversal error"));
IF(GETBIT(fault, 14) != 0, ADDERROR("Parallel error"));
IF(GETBIT(fault, 15) != 0, ADDERROR("Serial number error"));
END
```

Atribute de service

Product Code

```taphome
MODBUSR(H, 0x2000, Uint16);
```

System State

```taphome
SWITCH(MODBUSR(H, 0x0404, Uint16),
0, "Waiting",
1, "Detection",
2, "Grid-connected",
3, "Emergency power supply",
4, "Recoverable fault",
5, "Permanent fault",
6, "Upgrade",
7, "Self-charging",
"Fault")
```

Ambient Temperature

```taphome
MODBUSR(H, 0x0418, Int16) + "°C";
```

SOC baterie 1 Intrare analogică Doar citire

Starea de încărcare a bateriei 1 în procente — include atribute de service pentru temperatură, tensiune, curent, putere și SOH

Registru: H:0x0608 Uint16 Unitate: % numeric

Atribute de service

|             |
|-------------|
| Temperatură |
| Tensiune    |
| Curent      |
| Putere      |
| SOH         |

Citirea nivelului de intrare

```taphome
MODBUSR(H, 0x0608, Uint16)
```

Atribute de service

Temperature

```taphome
MODBUSR(H, 0x0607, Int16) + "°C";
```

Voltage

```taphome
MODBUSR(H, 0x0604, Uint16) + " V";
```

Current

```taphome
MODBUSR(H, 0x0605, Int16)/100 + " A";
```

Power

```taphome
MODBUSR(H, 0x0606, Int16)/100 + " kW";
```

SOH

```taphome
MODBUSR(H, 0x0609, Uint16) + " %";
```

SOC baterie 2 Intrare analogică Doar citire

Starea de încărcare a bateriei 2 în procente — disponibilă la modelele HYD 10–20KTL-3PH cu două intrări pentru baterii

Registru: H:0x060F Uint16 Unitate: % numeric

Atribute de service

|             |
|-------------|
| Temperatură |
| Tensiune    |
| Curent      |
| Putere      |
| SOH         |

Citirea nivelului de intrare

```taphome
MODBUSR(H, 0x060F, uint16)
```

Atribute de service

Temperature

```taphome
MODBUSR(H, 0x060E, Int16) + " °C";
```

Voltage

```taphome
MODBUSR(H, 0x060B, Uint16) + " V";
```

Current

```taphome
MODBUSR(H, 0x060C, Int16) + " A";
```

Power

```taphome
MODBUSR(H, 0x060D, Int16) + " kW";
```

SOH

```taphome
MODBUSR(H, 0x0610, Uint16) + " %";
```

Descărcare baterie azi Variabilă Doar citire

Energia zilnică descărcată din baterie în kWh — include totalul de la punerea în funcțiune

Registru: H:0x0698 Uint32 Unitate: kWh numeric

Atribute de service

|                          |
|--------------------------|
| Total descărcare baterie |

Citire

```taphome
MODBUSR(H, 0x0698, Uint32)/100
```

Atribute de service

Battery Discharge Total

```taphome
MODBUSR(H, 0x069A, Uint32)/10
```

Încărcare baterie azi Variabilă Doar citire

Energia zilnică încărcată în baterie în kWh — include totalul de la punerea în funcțiune

Registru: H:0x0694 Uint32 Unitate: kWh numeric

Atribute de service

|                         |
|-------------------------|
| Total încărcare baterie |

Citire

```taphome
MODBUSR(H, 0x0694, Uint32)/100
```

Atribute de service

Battery Charge Total

```taphome
MODBUSR(H, 0x0696, Uint32)/10
```

Energie cumpărată azi Variabilă Doar citire

Energia zilnică cumpărată din rețea în kWh — include totalul de la punerea în funcțiune

Registru: H:0x068C Uint32 Unitate: kWh numeric

Atribute de service

|                          |
|--------------------------|
| Energie cumpărată totală |

Citire

```taphome
MODBUSR(H, 0x068C, Uint32)/100
```

Atribute de service

Energy Purchase Total

```taphome
MODBUSR(H, 0x068E, Uint32)/10 + " kWh"
```

Energie vândută azi Variabilă Doar citire

Energia zilnică vândută în rețea în kWh — include totalul de la punerea în funcțiune

Registru: H:0x0690 Uint32 Unitate: kWh numeric

Atribute de service

|                        |
|------------------------|
| Energie vândută totală |

Citire

```taphome
MODBUSR(H, 0x0690, Uint32)/100
```

Atribute de service

Energy Selling Total

```taphome
MODBUSR(H, 0x0692, Uint32)/10
```

Frecvența rețelei Variabilă Doar citire

Registru: H:0x0484 UInt16 Unitate: Hz numeric

Citire

```taphome
MODBUSR(H, 0x484, UInt16)/100
```

Consum sarcini azi Variabilă Doar citire

Consumul zilnic al sarcinilor în kWh — include totalul de la punerea în funcțiune

Registru: H:0x0688 Int32 Unitate: kWh numeric

Atribute de service

|                      |
|----------------------|
| Consum sarcini total |

Citire

```taphome
MODBUSR(H, 0x0688, Int32)/100
```

Atribute de service

Load Consumption Total

```taphome
MODBUSR(H, 0x068A, Int32)/100 + "kWh"
```

Putere PV totală Variabilă Doar citire

Puterea însumată a tuturor stringurilor PV în kW

Registru: H:0x05C4 Uint16 Unitate: kW numeric

Citire

```taphome
MODBUSR(H, 0x05C4, Uint16)/10
```

Putere PV1 Variabilă Doar citire

Registru: H:0x0586 Uint16 Unitate: kW numeric

Atribute de service

|          |
|----------|
| Tensiune |
| Curent   |

Citire

```taphome
MODBUSR(H, 0x0586, Uint16)/100
```

Atribute de service

Voltage

```taphome
MODBUSR(H, 0x0584, Uint16)/10 + " V";
```

Current

```taphome
MODBUSR(H, 0x0585, Uint16)/100 + " A";
```

Putere PV2 Variabilă Doar citire

Registru: H:0x0589 Uint16 Unitate: kW numeric

Atribute de service

|          |
|----------|
| Tensiune |
| Curent   |

Citire

```taphome
MODBUSR(H, 0x0589, Uint16)/100
```

Atribute de service

Voltage

```taphome
MODBUSR(H, 0x0587, Uint16)/10 + " V";
```

Current

```taphome
MODBUSR(H, 0x0588, Uint16)/100 + " A";
```

Putere PV3 Variabilă Doar citire

Registru: H:0x058A Uint16 Unitate: kW numeric

Atribute de service

|          |
|----------|
| Tensiune |
| Curent   |

Citire

```taphome
MODBUSR(H, 0x058A, Uint16)/100
```

Atribute de service

Voltage

```taphome
MODBUSR(H, 0x058A, Uint16)/10 + " V";
```

Current

```taphome
MODBUSR(H, 0x058B, Uint16)/100 + " A"
```

Producție PV azi Variabilă Doar citire

Energia produsă zilnic de PV în kWh

Registru: H:0x0684 Int32 Unitate: kWh numeric

Citire

```taphome
MODBUSR(H, 0x0684, Int32)/100
```

Producție PV totală Variabilă Doar citire

Energia produsă de PV de la punerea în funcțiune, în kWh

Registru: H:0x0686 Int32 Unitate: kWh numeric

Citire

```taphome
MODBUSR(H, 0x0686, Int32)/100
```

Tensiune faza R Variabilă Doar citire

Tensiunea rețelei pe faza L1/R în V — include atributul de service pentru curentul fazei

Registru: H:0x048D Uint16 Unitate: V numeric

Atribute de service

|          |
|----------|
| Curent R |

Citire

```taphome
MODBUSR(H, 0x048D, Uint16)/10
```

Atribute de service

Current R

```taphome
MODBUSR(H, 0x048E, Uint16)/100 + " A";
```

Tensiune faza S Variabilă Doar citire

Tensiunea rețelei pe faza L2/S în V — include atributul de service pentru curentul fazei

Registru: H:0x0498 Uint16 Unitate: V numeric

Atribute de service

|          |
|----------|
| Curent S |

Citire

```taphome
MODBUSR(H, 0x0498, Uint16)/10
```

Atribute de service

Current S

```taphome
MODBUSR(H, 0x0499, Uint16)/100 + " A"
```

Tensiune faza T Variabilă Doar citire

Tensiunea rețelei pe faza L3/T în V — include atributul de service pentru curentul fazei

Registru: H:0x04A3 Uint16 Unitate: V numeric

Atribute de service

|          |
|----------|
| Curent T |

Citire

```taphome
MODBUSR(H, 0x04A3, Uint16)/10
```

Atribute de service

Current T

```taphome
MODBUSR(H, 0x04A4, Uint16)/100 + " A"
```

Putere activă totală la ieșire Variabilă Doar citire

Puterea activă totală la ieșirea invertorului în kW — include puterea reactivă și aparentă

Registru: H:0x0485 Int16 Unitate: kW numeric

Atribute de service

|                           |
|---------------------------|
| Putere reactivă la ieșire |
| Putere aparentă la ieșire |

Citire

```taphome
MODBUSR(H, 0x0485, Int16)/100
```

Atribute de service

Reactive Power Output

```taphome
MODBUSR(H, 0x0486, Int16)/100 + " kW" ;
```

Apparent Power Output

```taphome
MODBUSR(H, 0x0487, Int16)/100 + " kW" ;
```

Putere activă totală PPC Variabilă Doar citire

Puterea activă în punctul comun de cuplare (punctul de racordare la rețea) în kW — se folosește pentru limitarea injecției în rețea

Registru: H:0x0488 Int16 Unitate: kW numeric

Atribute de service

|                     |
|---------------------|
| Putere reactivă PPC |
| Putere aparentă PPC |

Citire

```taphome
MODBUSR(H, 0x0488, Int16)/100
```

Atribute de service

Reactive Power PPC

```taphome
MODBUSR(H, 0x0489, Int16)/100 + " kW" ;
```

Apparent Power PPC

```taphome
MODBUSR(H, 0x048A, Int16)/100 + " kW" ;
```

**Conexiune:** Modbus RTU • 9600 baud• 8N1 • Slave ID: $\[SlaveId]

Îmbunătățiri posibile (12)

- H:0x1104 Remote Switch On/Off — Remote inverter on/off control — useful for TapHome automation
- H:0x1110 Energy Storage Mode — Operating mode selection: Self-use, Time-of-Use, Timing, Passive, Peak Shaving, Off-grid
- H:0x1187 Passive Battery Charge/Discharge — S32, external Modbus control of battery charge/discharge power — enables TapHome smart rule energy management
- H:0x0200 Running State — 0=Wait, 1=CheckState, 2=Normal, 3=CheckDischarge, 4=Discharge, 5=EPS, 6=Fault, 7=Permanent — older register range, covered by H:0x0404 System State in module
- H:0x0504 Off-Grid Active Power — EPS/backup output power (S16, 0.01 kW) — relevant for off-grid/backup scenarios
- H:0x050A-0x0522 Off-Grid Per-Phase Voltage/Current/Power — L1/L2/L3 off-grid output monitoring — 9 registers for 3-phase EPS output
- H:0x0507 Off-Grid Frequency — EPS output frequency (U16, 0.01 Hz)
- H:0x048F-0x04A7 Per-Phase Active/Reactive Power and Power Factor — L1/L2/L3 individual active power, reactive power, and power factor — template only reads voltage+current per phase
- H:0x058D-0x058F PV4 Voltage/Current/Power — PV string 4 input — template supports up to PV3. HA integration supports up to PV10
- H:0x0612-0x0627 Battery 3–6 Parameters — Additional battery packs (voltage, current, power, temperature, SOC, SOH, cycles) — template supports battery 1–2 only
- H:0x022C Battery Cycle Count — Battery cycle times (Uint16, 0–65536) — available at 0x060A per battery in HA integration
- H:0x0419 Heatsink Temperature — Inverter heatsink temperature (S16, °C) — template reads inner temperature (0x0418) only

## Parametri de import

Introduceți aceste valori când importați XML-ul.

| Solicitat în aplicație | Implicit      |
|------------------------|---------------|
| Slave ID               | `1`           |
| Adresă IP              | `192.168.1.0` |

## Surse

- SOFARSOLAR ModBus-RTU Communication Protocol
  
  [community.openenergymonitor.org](https://community.openenergymonitor.org/uploads/short-url/dF8j79PsvtCS0xQ5aPxHXO4HZDE.pdf) 2026-03-28
  
  [PDF](https://taphome.com/compatibility/devices/sofarsolar-inverter-3p/manufacturer/sofarsolar-modbus-rtu-protocol.pdf)
- HYD 5/6/8/10/15/20KTL-3PH User Manual
  
  [www.sofarsolar.com](https://www.sofarsolar.com/upload/file/20240321/1710982866939025487.pdf) 2026-03-28
  
  [PDF](https://taphome.com/compatibility/devices/sofarsolar-inverter-3p/manufacturer/hyd-5-20ktl-3ph-user-manual.pdf)
- Home Assistant SolaX/Sofar Modbus Integration
  
  [github.com](https://github.com/wills106/homeassistant-solax-modbus) 2026-03-28

Documentele producătorilor sunt © ale proprietarilor respectivi. Sunt furnizate așa cum au fost publicate de producător, doar ca referință.

## Documentație asociată

- [Modbus Integration](https://taphome.com/ro/compatibility/modbus-guide/)
- [Modbus](https://taphome.com/ro/docs/integration/modbus/)
- [Configurare simplă cu ajutorul șabloanelor](https://taphome.com/ro/docs/integration/modbus/templates/)
- [Scripturi Modbus și prefetch](https://taphome.com/ro/docs/script/modbus-scripts/)
- [Funcții Modbus](https://taphome.com/ro/docs/script/modbus/)
- [Tipuri de date Modbus](https://taphome.com/ro/docs/script/modbus-data-types/)