  topics: ["modbus-rtu","air-recovery","rs485","heat-pump","ventilation","hot-water","heat-recovery"]
  questions: ["Hogyan integralhato a Flexit EcoNordic a TapHome-mal?","Mit vezerel a Flexit EcoNordic sablon a TapHome-ban?","Hogyan csatlakoztathato a Flexit EcoNordic RS-485-on keresztul a TapHome-hoz?","Mi a kulonbseg az EcoNordic WH4 es W4 kozott a TapHome-ban?","Hogyan aktivalhato a kandallo szellozesi mod a Flexit EcoNordic-on a TapHome-on keresztul?","Hogyan vezerelheto a melegviz-termeles a Flexit EcoNordic-on?"]
---

# Flexit EcoNordic WH4 / W4

Kommunikáció: Modbus RTU

- [Flexit hivatalos weboldal](https://www.flexit.no)

## Integrációs útmutató

A Flexit EcoNordic egy klimakozpont, amely egyensulyi szellozest hovisszanyeressel, hasznalati melegviz-termelest es vizes futest (WH4 modell) kombinat. A TapHome-mal Modbus RTU-n keresztul kommunikal RS-485-on, lehetove teve a szellozesi modok vezerleset, homerseklet-beallitasokat, melegviz-kezelest es a hoszivattyú mukodesenek felugyelet.

Ket modell tamogatott: **EcoNordic WH4** (szellozes + futes + melegviz) es **EcoNordic W4** (szellozes + melegviz). A WH4 tovabbi futesi kor erzekelokkel es vezerlesekkel rendelkezik, amelyek a W4-en nem erhetek el.

## Hardveres csatlakozas

Az EcoNordic beepitett Modbus RTU interfeszszel rendelkezik, RS-485-on keresztul erheto el. Csatlakoztassa a TapHome Core-t az EcoNordic RS-485 portjahoz sodrott erparral es GND-vel.

> [!WARNING]
> Az elerheto dokumentacioban nem talalhato bekotesi rajz. Az RS-485 csatlakozok pontos helyet az EcoNordic telepitesi kezikonyveben talaja, vagy forduljon a Flexit tamogatashoz. Az opcionalis **Modbus kabel (HP Res)** tartozek a Flexittol szerezheto be kulso vezerlokhoz.

## Konfiguracio

Allitsa be a Modbus kapcsolatot a TapHome-ban az alabbi parametrekkel:

| Parameter | Ertek |
|-----------|-------|
| Baud rate | 9600 |
| Adatbitek | 8 |
| Paritas | Even |
| Stop bitek | 1 |
| Slave ID | 1 (alapertelmezett) |

Az EcoNordic sajat Modbus regiszterterkepet hasznalja az 1-3037 cimtartomanyban. Ez elter a regebbi Flexit Nordic S2-S4 / CL2-CL4 modellek altal hasznalt CI66 regiszterterkeptol — CI66 adapter nem szukseges.

> [!NOTE]
> Az EcoNordic a **Flexit GO** mobilalkalmazassal (Android/iOS) is vezérelheto. A TapHome es a Flexit GO alkalmazas egyidejuleg mukodhet — mindketto fuggetlenul kommunikal az egyseggel.

## Eszkozkepes segek

### Szellozesi mod vezerles

Az **Uzemmod** (H:2013) az elsodleges szellozesvezerles negy moddal:

- **Stop** — ventilatorok kikapcsolva, nincs szellozes
- **Away** — csokentett szellozes lakatlan epulethez
- **Home** — normalis napi uzem
- **High** — ideiglenesen fokozott szellozes

Ket specialis trigger tovabbi szellozesi modokat biztosit:

- **Gyors szellozes** (H:3006) — ideiglenes nagysebessegu szellozest aktival gyors legcserere (fozes, latogatok, para). Az idotartam szervizmuveleten keresztul allithato (1-360 perc)
- **Kandallo szellozes** (H:3007) — pozitiv belteri nyomast hoz letre, hogy megakadalyozza a fust behatolasat a helyisegbe a kandallo meggyujtasakor. Az idotartam szervizmuveleten keresztul allithato (0-360 perc)

A **Comfort gomb** (H:2040) atkapcsolja a komfort modot az egysegen, amely ideiglenesen noveli a szellozest es modosithatja a homerseklet-beallitasokat.

### Homerseklet-felugyeletes es beallitasok

A sablon hat homerseklet-erzekelot biztosit:

- **Kulso levego homerseklete** (A:1) — kulteri levego homerseklete a beszivo nyilasnal
- **Befuvo levego homerseklete** (A:5) — friss levego az epuletbe juttatva hovisszanyeres es utofutes utan
- **Elszivo levego homerseklete** (A:9) — az epuletbol elszivott levego hovisszanyeres elott
- **Kifuvo levego homerseklete** (A:13) — a kulteri levegobe kifujt levego hovisszanyeres utan
- **Futesi kor eloremenoi homerseklet** (A:97) — viz homerseklete a futesi kor eloremeno csoveben (csak WH4)
- **Futesi kor visszatero homerseklet** (A:101) — viz homerseklete a futesi kor visszatero csoveben (csak WH4)

Ket termosztat vezerli a befuvo levego homerseklet-beallitasait:

- **Homerseklet Home modban** (H:1155) — beallitas Home modhoz, tartomany 10-30°C
- **Homerseklet Away modban** (H:1163) — beallitas Away modhoz, tartomany 10-30°C

### Melegviz-kezeles

A **Melegviz mod** (H:3017) kivalasztja a hasznalati melegviz futesi strategiajat:

- **Comfort** — tolti a tartalyt kb. 50% maradek melegviznel, 15% alatt elektromos tartalek futot hasznal
- **Economy** — legtakarekosabb mod, csak kb. 15% maradeknal tolt, elektromos tartalek nelkul

A **Melegviz boost** (H:3019) ideiglenes maximalis melegviz-termelest indit az elektromos tartalek futovel. Az idotartam szervizmuveleten keresztul allithato (0-300 perc).

### Hoszivattyú es rendszerfelugyeletes

A modul kilenc szervizattributumot kinal a rendszerallapot felugyeletehez:

- **Hoszivattyú allapota** (A:3028) — aktualis hoszivattyú mukodes: Keszenleti, Legtelenites, Inditas, Normalis mukodes, Leallitas, Olvasztas, Hibas keszenleti, Kezi es Kenyszeritett mukodes
- **Hasznalati melegviz allapota** (A:3005) — melegviz-termeles allapota: Comfort, Economy, Nincs hasznlatban, Ideiglenes boost, Kenyszeritett toltes, Economy kesleltetes vagy Legionella megelozes
- **Hovisszanyero szellozes allapota** (A:3034) — az aktualis szellozesi allapotot mutatja, beleertve az Uzemmodon keresztul kozvetlenul nem allithato modokat (pl. Paraelszivo es Kandallo)
- **Hoszivattyú uzemmodja** (H:2061) — reszletes 17 allapotu enum, amely mutatja mit csinal a hoszivattyú (tartaly toltes, terfutes, szellozesi futes, Legionella megelozes es kombinalt modok)
- **Hoszivattyú utofutotest** (A:3029) — az utofutotest aktiv-e
- **Hoszivattyú fagyvedelme** (A:3031) — a fagyvedelem aktiv-e
- **Csepptalca melgito allapota** (A:3036) — a csepptalca melegito aktiv-e
- **Hoszivattyú vizko figyelmeztes** (A:3037) — figyelmeztes vizko lerakodas eszlelesekor
- **Hoszivattyú csappantyu pozicioja** (H:29) — csappantyu pozicio szazalekban

Tovabbi szervizattributumok erhetek el az egyes eszkozokon: elszivo ventilator sebesseg, csappantyu parancsok, forgo hocsrelo sebesseg, hoszivattyú beallitott eloremeno homerseklet, termikus teljesitmeny, futesi kor keringteto szivattyú sebesseg es tarolotartaly fogyasztoi szelep pozicioja.

### Riasztaskezeles

A ReadScript modul ket riasztasi csatornat figyel — **Alarm A** es **Alarm B**. Amikor egy riasztas aktiv (allapot = 2), a TapHome hibakent jelenti a riasztasi ertekkel es a nyugtazasi allapottal (Nyugtazott/Nem nyugtazott/Zarolt).

Harom szervizmuvelet erheto el a riasztaskezeleshez:

- **Alarm A nyugtazasa** — nem nyugtazott riasztas nyugtazasa
- **Alarm B nyugtazasa** — nem nyugtazott riasztas nyugtazasa
- **Osszes inaktiv riasztas eltavolitasa** — torli az osszes inaktiv/nyugtazott riasztast a rendszerbol

### Tovabbi kepessegek

Az EcoNordic tamogatja a szuroidozitokat, a hovisszanyeresi hatekonysag szamitast, a befuvo ventilator sebesseg felugyeletet es a futesi gorbe beallitasokat (WH4). A hovisszanyero szellozes allapota tovabbi modokat mutat (Paraelszivo, Kandallo, Ideiglenesen magas) az Uzemmod vezerles altal kozvetlenul kinaltakon tul. Ezek a kepessegek egy jovobeni sablonfrissitesben adhatoak hozza.

> [!TIP]
> Az EcoNordic **-25°C kulteri homersekletig** mukodik CO2 hoszivattyujaval. A forgo hocsrelo akar 90%-os homersekleti hatekonyagot biztosit a hovisszanyereshez. Kovesse nyomon a befuvo es elszivo levego homerseklete kozti kulonbseget a hovisszanyeres teljesitmenyenek megiteleshez.

## Hibaelharitas

### Nincs Modbus kommunikacio

1. Ellenorizze az RS-485 kabelkapcsolatokat a TapHome es az EcoNordic egyseg kozott
2. Erositise meg a kommunikacios parametreket: **9600 baud, 8-E-1** (Even paritas, nem None)
3. Ellenorizze, hogy a Slave ID a TapHome-ban megegyezik-e az egyseg konfiguracioval (alapertelmezett: 1)
4. Bizonyosodjon meg rola, hogy az EcoNordic be van kapcsolva es mukodokepes

### Futesi kor erzekelok nem mutatnak adatot (WH4)

A futesi kor eloremeno es visszatero homerseklet erzekelok csak a **WH4** modellnel erhetek el. Ha W4-et hasznal (csak szellozes + melegviz), ezek az erzekelok nem jelentenek ertekeket.

### Riasztasok jelentese a TapHome-ban

1. Ellenorizze a riasztasi reszleteket a TapHome szervizattributumokban — a riasztasi ertek es allapot megjelenik
2. Hasznalja a **Riasztas nyugtazasa** szervizmuveletet az aktiv riasztas nyugtazasahoz
3. A riasztasi kodok ertelmezesehez nezze meg a Flexit GO alkalmazast vagy a felhasznaloi kezikonyvet
4. Gyakori okok: eldugult szurok, leallo rotor, tulmelgedesi vedelem kioldasa, vizrendszer problemak

## Elérhető eszközök 14

Ezek az eszközök az importálás után jelennek meg a TapHome-ban.

Flexit EcoNordic Modul

Szerviz attribútumok

|                                  |                                                                                                                                                |
|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|
| Hoszivattyú allapota             | Hoszivattyú uzemallpota — Keszenleti, Legtelenites, Inditas, Normalis mukodes, Stop, Olvasztas, Hiba, Kezi, Kenyszeritett ventilator/szivattyú |
| Hasznalati melegviz allapota     | Aktualis melegviz-termeles allapot — Comfort, Economy, Nincs hasznlatban, Boost, Kenyszeritett toltes, Legionella megelozes                    |
| Hovisszanyero szellozes allapota | Aktualis szellozesi allapot — Ki, Away, Home, High, Paraelszivo, Kandallo, Ideiglenesen magas                                                  |
| Hoszivattyú uzemmodja            | Hoszivattyú uzemmod — mutatja mit csinal a hoszivattyú (tartaly toltes, terfutes, szellozesi futes, Legionella megelozes)                      |
| Hoszivattyú utofutotest          |                                                                                                                                                |
| Hoszivattyú fagyvedelme          |                                                                                                                                                |
| Csepptalca melegito allapota     |                                                                                                                                                |
| Hoszivattyú vizko figyelmeztes   |                                                                                                                                                |
| Hoszivattyú csappantyu pozicioja |                                                                                                                                                |

Szerviz műveletek

|                                      |
|--------------------------------------|
| Osszes inaktiv riasztas eltavolitasa |
| Alarm A nyugtazasa                   |
| Alarm B nyugtazasa                   |

Olvasás (modul)

```taphome
IF MODBUSR(A,3001, Uint16) = 2
ADDERROR(MODBUSR(A, 1021, float), "Alarm A: " + 
SWITCH(MODBUSR(A,3002, Uint16),
1, "Acknowledged, unlocked ",
2, "Unacknowledged",
3, "Locked",
"Unknown" ));
END

IF MODBUSR(A,3003, Uint16) = 2
ADDERROR(MODBUSR(A, 1023, float), "Alarm B: " + 
SWITCH(MODBUSR(A,3004, Uint16),
1, "Acknowledged, unlocked ",
2, "Unacknowledged",
3, "Locked",
"Unknown" ));
END
```

Szerviz attribútumok

Heat Pump Status

```taphome
SWITCH(MODBUSR(A, 3028, Uint16), 
1, "Standby", 
2, "Air Purge process",
3, "Startup process",
4, "Normal operation",
5, "Stop process", 
6, "Defrost operation",
7, "Standby when error",
8, "Manual operation",
9, "Forced fan operation",
10, "Forced pump operation",
11, "State 10",
12, "State 11",
13, "State 12",
14, "State 13",
15, "State 14",
16, "State 15",
"Unknown"
)
```

Domestic hot water state

```taphome
SWITCH(MODBUSR(A, 3005, Uint16),
1, "Comfort",
2, "Economy", 
3, "Not in Use",
4, "Temporary Boost",
5, "Forced Charge",
6, "Economy delay",
7, "Legionella prevention",
"Unknown"
);
```

Heat recovery ventilation state

```taphome
SWITCH(MODBUSR(A, 3034, Uint16),
1, "Off", 
2 , "Away" , 
3 , "Home" , 
4 , "High", 
5 , "Fume hood", 
 6 , "Fireplace", 
 7 , "Temporary high",
 "Unknown");
```

Plant operating mode for heat pump

```taphome
SWITCH(MODBUSR(H, 2061, Uint16), 
1 , "Off" , 
2 , "Vent.heating from tank" , 
3 , "Load tank" ,
4 , "Load tank & vent.heating" ,
5 , "Space heating from tank" , 
6 , "Space heat.& vent.heat.from tank",
7 , "Load tank & space heat" , 
8 , "Load tank & space heat.& vent" , 
9 , "HP not available" , 
10 , "Swi-off delay flow through heat",
11 , "Legionella prev.vent.heat" , 
12 , "Legionella prev.space heat" , 
13 , "Space heat.with HP" ,
14 , "Space heat.& vent.with HP" , 
15 , "Load tank & space heat.with HP" , 
16 , "Load tank & vent.& space with HP", 
17 , "Legionella prev.tank",
"Unknown")
```

Heat Pump Reheating Coil

```taphome
Switch (MODBUSR(A, 3029, Uint16), 1, "Active", 0, "Inactive", "Unknown");
```

Heat Pump Frost Protection

```taphome
Switch (MODBUSR(A, 3031, Uint16), 1, "Active", 0, "Inactive", "Unknown");
```

Drain Pan Heater State

```taphome
Switch (MODBUSR(A, 3036, Uint16), 1, "Active", 0, "Inactive", "Unknown");
```

Heat pump warning limescale

```taphome
Switch (MODBUSR(A, 3037, Uint16), 1, "Active", 0, "Inactive", "Unknown");
```

Heat Pump Connection Dumper position

```taphome
MODBUSR(H, 29, Float, 2) + " %"
```

Szerviz műveletek

Remove All Inactive Alarms

```taphome
MODBUSW(H, 3004, Uint16, 3);
```

Acknowledge Alarm A

```taphome
MODBUSW(H, 3002, Uint16, 2)
```

Acknowledge Alarm B

```taphome
MODBUSW(H, 3003, Uint16, 2)
```

Comfort gomb Kapcsoló Olvasás és írás

Regiszter: H:2040 Bool

Értékek / Állapotok: Active · Inactive

Kapcsoló állapot olvasása

```taphome
MODBUSR(H, 2040, Bool)
```

Kapcsoló állapot írása

```taphome
MODBUSW(H, 2040, Bool, St)
```

Kifuvo levego homerseklete Hőmérséklet-érzékelő Csak olvasható

A hovisszanyeres utan a szabadba kifujt levego homerseklete

Regiszter: A:13 Float Egység: °C numeric

Szerviz attribútumok

|                                              |
|----------------------------------------------|
| Elszivo ventilator sebesseg                  |
| Kifuvo levego csappantyu parancs             |
| Hoszivattyú kifuvo levego csappantyu parancs |

Hőmérséklet olvasása

```taphome
MODBUSR(A, 13, Float, 2)
```

Szerviz attribútumok

Exhaust Air Fan Speed

```taphome
 ROUND(MODBUSR(H, 9, Float, 2)) + " %"
```

Exhaust Air Damper Command

```taphome
Switch (MODBUSR(H, 2010, Uint16), 1, "Active", 0, "Inactive", "Unknown");
```

Heat pump exhaust air damper command

```

```

Elszivo levego homerseklete Hőmérséklet-érzékelő Csak olvasható

Az epuletbol hovisszanyeres elott elszivott levego homerseklete

Regiszter: A:9 Float Egység: °C numeric

Szerviz attribútumok

|                                              |
|----------------------------------------------|
| Hoszivattyú kifuvo levego csappantyu parancs |

Hőmérséklet olvasása

```taphome
MODBUSR(A, 9, Float , 2)
```

Szerviz attribútumok

Heat pump exhaust air damper command

```taphome
Switch (MODBUSR(H, 2064, Uint16), 1, "Active", 0, "Inactive", "Unknown");
```

Futesi kor eloremeno homerseklet Hőmérséklet-érzékelő Csak olvasható

Viz homerseklete a futesi kor eloremeno csoveben — csak WH4 modell

Regiszter: A:97 Float Egység: °C numeric

Szerviz attribútumok

|                                              |
|----------------------------------------------|
| Forgo hocsrelo sebesseg                      |
| Hoszivattyú beallitott eloremeno homerseklet |
| Hoszivattyú termikus teljesitmeny            |

Hőmérséklet olvasása

```taphome
MODBUSR(A, 97, Float, 2)
```

Szerviz attribútumok

Rotary heat exchanger speed

```taphome
 ROUND(MODBUSR(H, 1, Float, 2)) + " %"
```

Heat pump setpoint flow temperature

```taphome
MODBUSR(H, 73, Float, 2) + " °C"
```

Heat Pump Thermic Power Output

```taphome
MODBUSR(H, 65, Float, 2) + " kW"
```

Futesi kor visszatero homerseklet Hőmérséklet-érzékelő Csak olvasható

Viz homerseklete a futesi kor visszatero csoveben — csak WH4 modell

Regiszter: A:101 Float Egység: °C numeric

Hőmérséklet olvasása

```taphome
MODBUSR(A, 101, Float, 2)
```

Melegviz boost Többértékű kapcsoló Olvasás és írás

Ideiglenes maximalis melegviz-termeles — Kesz, Start, Stop

Regiszter: H:3019 UInt16 numeric

Értékek / Állapotok: Ready · Start · Stop

Szerviz műveletek

|                  |
|------------------|
| Boost idotartama |

Kapcsoló állapot olvasása

```taphome
MODBUSR(H, 3019, UInt16)
```

Kapcsoló állapot írása

```taphome
MODBUSWNE(H, 3019, UInt16, Mu)
```

Szerviz attribútumok

Duration of boost

```taphome
MODBUSR(H, 1513, Uint32) + " min";
```

Szerviz műveletek

Duration of boost

Paraméterek: Duration \[0-300 min] (0–300 dur)

```taphome
MODBUSW(H, 1513, Uint32, dur);
```

Melegviz mod Többértékű kapcsoló Olvasás és írás

Hasznalati melegviz strategia — Comfort (50%-nal tolt) vagy Economy (15%-nal tolt)

Regiszter: H:3017 UInt16 numeric

Értékek / Állapotok: Comfort · Economy

Kapcsoló állapot olvasása

```taphome
MODBUSR(H, 3017, UInt16)
```

Kapcsoló állapot írása

```taphome
MODBUSW(H, 3017, UInt16, Mu)
```

Szerviz attribútumok

Heating circuit pump speed

```taphome
MODBUSR(H, 61, Float, 2) + " %"
```

Storage tank consumer valve position

```taphome
 ROUND(MODBUSR(H, 57, Float, 2)) + " %"
```

Uzemmod Többértékű kapcsoló Olvasás és írás

Szellozesi uzemmod — Stop, Away, Home, High

Regiszter: H:2013 UInt16 numeric

Értékek / Állapotok: Stop · Away · Home · High

Kapcsoló állapot olvasása

```taphome
MODBUSR(H, 2013, Uint16)
```

Kapcsoló állapot írása

```taphome
MODBUSW(H, 2013, Uint16, Mu)
```

Kulso levego homerseklete Hőmérséklet-érzékelő Csak olvasható

Regiszter: A:1 Float Egység: °C numeric

Hőmérséklet olvasása

```taphome
MODBUSR(A, 1, Float)
```

Befuvo levego homerseklete Hőmérséklet-érzékelő Csak olvasható

Az epuletbe juttatott friss levego homerseklete hovisszanyeres es utofutes utan

Regiszter: A:5 Float Egység: °C numeric

Hőmérséklet olvasása

```taphome
MODBUSR(A, 5, Float, 2)
```

Homerseklet Away modban Termosztát Olvasás és írás

Befuvo levego homerseklet-beallitas Away modhoz (10-30°C)

Regiszter: H:1163 Float Egység: °C numeric

Kívánt hőmérséklet olvasása

```taphome
MODBUSR(H, 1163, Float, 2)
```

Kívánt hőmérséklet írása

```taphome
MODBUSW(H, 1163, Float, Se)
```

Homerseklet Home modban Termosztát Olvasás és írás

Befuvo levego homerseklet-beallitas Home modhoz (10-30°C)

Regiszter: H:1155 Float Egység: °C numeric

Kívánt hőmérséklet olvasása

```taphome
MODBUSR(H, 1155, Float, 2)
```

Kívánt hőmérséklet írása

```taphome
MODBUSW(H, 1155, Float, Se)
```

Kandallo szellozes Többértékű kapcsoló Olvasás és írás

Tulnyomasi modot aktival a fust behatolasanak megakadalyozasara a kandallo meggyujtasakor — Kesz, Inditas

Regiszter: H:3007 UInt16 numeric

Értékek / Állapotok: Ready · Trigger

Szerviz műveletek

|                               |
|-------------------------------|
| Kandallo szellozes futasi ido |

Kapcsoló állapot olvasása

```taphome
MODBUSR(H, 3007,UInt16)
```

Kapcsoló állapot írása

```taphome
MODBUSWNE(H, 3007, UInt16, Mu)
```

Szerviz attribútumok

Fireplace Ventilation Runtime

```taphome
MODBUSR(H, 1105, Uint32) + " min"
```

Szerviz műveletek

Fireplace Ventilation Runtime

Paraméterek: duration \[0 - 360 min] (0–360 dur)

```taphome
MODBUSW(H, 1105, Uint32, dur)
```

Gyors szellozes Többértékű kapcsoló Olvasás és írás

Ideiglenes nagysebessegu szellozes gyors legcserehez — Kesz, Inditas

Regiszter: H:3006 UInt16 numeric

Értékek / Állapotok: Ready · Trigger

Szerviz műveletek

|                            |
|----------------------------|
| Gyors szellozes futasi ido |

Kapcsoló állapot olvasása

```taphome
MODBUSR(H, 3006, UInt16)
```

Kapcsoló állapot írása

```taphome
MODBUSWNE(H, 3006, UInt16, Mu)
```

Szerviz attribútumok

Rapid ventilation runtime

```taphome
MODBUSR(H, 1103, Uint32) + " min"
```

Szerviz műveletek

Rapid Ventilation Runtime

Paraméterek: Duration \[1-360 min] (1–360 dur)

```taphome
MODBUSW(H, 1103, Uint32, dur)
```

**Kapcsolat:** Modbus RTU • 9600 baud• 8E1 • Slave ID: $\[SlaveId]

Lehetséges fejlesztések (7)

- pyflexit CI66 Register Map (Nordic S2–S4, CL2–CL4) — Complete CI66 adapter register map (addresses 0–48) for Nordic models — NOT applicable to EcoNordic which uses proprietary registers
- H:2013 value 5+ Fume Hood and Calendar Modes — Heat Recovery Ventilation State shows values 5=Fume hood, 6=Fireplace, 7=Temporary high — but Operating Mode (H:2013) only exposes Stop/Away/Home/High (1–4). Fume hood may require separate trigger register
- unknown Filter Timer / Filter Alarm — CI66 has filter operating hours (reg 8), filter alarm (reg 27), filter alarm period (reg 46). EcoNordic likely has equivalent registers but they are not in the XML template
- unknown Heat Recovery Efficiency — CI66 exposes heat recovery percentage (0–100%). EcoNordic may have equivalent register — can be calculated from supply/extract/outside temperatures
- unknown Supply Air Fan Speed — Exhaust fan speed is exposed (H:9) but supply fan speed is missing from the template. EcoNordic likely has this register
- unknown Heating Circuit Setpoint Temperature — WH4 heating set value and parallel shift for the heat curve — not exposed in the template
- doc 2882 (404) Full EcoNordic Modbus Register Map — Official Flexit Modbus EcoNordic Basic XLSX register map returned 404 — may contain additional registers not in the XML template

## Importálási paraméterek

Ezeket az értékeket az XML importálásakor adja meg.

| Az alkalmazás kéri | Alapérték     |
|--------------------|---------------|
| Slave ID           | `1`           |
| IP-cím             | `192.168.1.0` |

## Források

- pyflexit — Flexit Modbus Python Library (register map)
  
  [github.com](https://github.com/Sabesto/pyflexit) 2026-03-20
- Home Assistant Flexit Integration
  
  [www.home-assistant.io](https://www.home-assistant.io/integrations/flexit/) 2026-03-20
- EcoNordic WH4/W4 User Manual (116927EN-07)
  
  [assets.ctfassets.net](http://assets.ctfassets.net/wzjhf3pmxyuk/1woGygq1Dvw0xDHElh4Sss/ce551d1f9cc20887831301048b1c2dce/EcoNordic_WH4_-_W4_Vartotojo_instrukcija_EN.pdf) 2026-03-20
  
  [PDF](https://taphome.com/compatibility/devices/flexit-econordic/manufacturer/econordic-user-manual.pdf)
- EcoNordic WH4 Product Data Sheet (117290EN-01)
  
  [nit.lt](https://nit.lt/wp-content/uploads/2019/02/flexit-EcoNordic-WH4-eng.pdf) 2026-03-20
  
  [PDF](https://taphome.com/compatibility/devices/flexit-econordic/manufacturer/econordic-assembly-manual.pdf)

A gyártói dokumentumok © a mindenkori tulajdonosaikat illetik. A gyártó által közzétett formában, kizárólag tájékoztatásul tesszük elérhetővé őket.

## Kapcsolódó dokumentáció

- [Modbus Integration](https://taphome.com/hu/compatibility/modbus-guide/)
- [Modbus útmutató a TapHome készülékekhez](https://taphome.com/hu/docs/integration/modbus/)
- [Egyszerű konfiguráció sablonok használatával](https://taphome.com/hu/docs/integration/modbus/templates/)
- [Modbus szkriptek és prefetch](https://taphome.com/hu/docs/script/modbus-scripts/)
- [Modbus függvények](https://taphome.com/hu/docs/script/modbus/)
- [Modbus adattípusok](https://taphome.com/hu/docs/script/modbus-data-types/)