title: "Sofar Solar HYD KTL-3PH"
description: "Trofazni hibridni izmjenjivač Sofar Solar HYD 5-20KTL-3PH s baterijskom pohranom, praćen preko Modbus RTU na RS-485."
url: "https://taphome.com/hr/compatibility/sofarsolar-inverter-3p/"
language: hr
lastmod: 2026-10-08
generator: hugo
ai:
  topics: ["modbus-rtu","inverter","rs485","3-phase","hybrid-inverter","battery-storage","pv-monitoring"]
  questions: ["Kako integrirati izmjenjivač Sofar Solar HYD KTL-3PH sa sustavom TapHome?","Što prati predložak TapHome za Sofar Solar HYD KTL-3PH?","Kako spojiti Sofar Solar HYD KTL-3PH preko RS-485 na TapHome?","Kako spojiti više izmjenjivača Sofar Solar na jednu sabirnicu RS-485?","Koje parametre baterije čita predložak TapHome za Sofar Solar?","Kako u sustavu TapHome pratiti fotonaponsku proizvodnju i energiju mreže?"]
---

# Sofar Solar HYD KTL-3PH

Komunikacija: Modbus RTU

- [Službena web-stranica Sofar Solar](https://www.sofarsolar.com)

## Upute za integraciju

Sofar Solar HYD 5/6/8/10/15/20KTL-3PH je serija trofaznih hibridnih izmjenjivača (inverter) koji kombiniraju fotonaponsku proizvodnju s baterijskom pohranom energije. TapHome se spaja preko Modbus RTU na RS-485 putem 16-pinskog priključka COM izmjenjivača i čita holding registre za trenutačnu fotonaponsku proizvodnju, stanje baterije, snagu mreže, napone po fazama i brojače energije.

Izmjenjivač podržava do 31 uređaja na jednoj sabirnici RS-485 u linijskoj topologiji (daisy chain). Svaki izmjenjivač treba jedinstveni Modbus Slave ID (može se postaviti, zadano 1). Komunikacijski parametri su fiksni: 9600 baud, 8N1.

## Spajanje uređaja

### Komunikacijska sučelja

![Položaj komunikacijskih sučelja izmjenjivača Sofar Solar HYD KTL-3PH](https://taphome.com/images/compatibility/sofarsolar-inverter-3p/communication-interfaces_hu_5a569478a95349ec.jpg)

Veza RS-485 za praćenje iz sustava TapHome koristi **priključak COM**, 16-pinski višenamjenski konektor na donjoj strani izmjenjivača.

### Raspored pinova priključka COM

![Raspored pinova 16-pinskog priključka COM izmjenjivača Sofar Solar HYD KTL-3PH](https://taphome.com/images/compatibility/sofarsolar-inverter-3p/com-port-pinout_hu_1534b25dbbb0b858.jpg)

**Pinovi važni za spajanje sustava TapHome:**

| Pin | Funkcija | Napomena |
|-----|----------|------|
| **1** | RS485A1-1 (+) | Signal A RS-485 za praćenje i upravljanje |
| **2** | RS485A1-2 (+) | Drugi konektor za linijsko spajanje |
| **3** | RS485B1-1 (-) | Signal B RS-485 |
| **4** | RS485B1-2 (-) | Drugi konektor za linijsko spajanje |
| 5 | RS485A2 (+) | Pametno brojilo — zasebna sabirnica |
| 6 | RS485B2 (-) | Pametno brojilo — zasebna sabirnica |
| 7 | CAN0_H | Komunikacija s BMS-om (CAN) |
| 8 | CAN0_L | Komunikacija s BMS-om (CAN) |

TapHome spojite na **pinove 1+3** (ili 2+4):
- **Pin 1 (RS485A1)** → A+/D+ na RS-485 sustava TapHome
- **Pin 3 (RS485B1)** → B-/D- na RS-485 sustava TapHome

> [!WARNING]
> **Ne koristite pinove 5+6**: namijenjeni su pametnom brojilu na zasebnoj sabirnici RS-485. Za Modbus praćenje TapHome mora biti spojen na pinove 1+3 (ili 2+4).

### Linijsko ožičenje RS-485 (daisy chain)

![Linijsko ožičenje RS-485 (daisy chain) za više izmjenjivača Sofar Solar](https://taphome.com/images/compatibility/sofarsolar-inverter-3p/wiring-rs485-daisy-chain_hu_1365fa6dd95340c6.jpg)

Kod spajanja više izmjenjivača povežite ih sabirnicom RS-485 u linijskoj topologiji (daisy chain). Na prvom i posljednjem uređaju na sabirnici između pina 1 i pina 4 postavite **zaključni otpornik od 120 Ω**.

**Specifikacija kabela:**
- Vrsta: oklopljena upredena parica, presjek bakrenog vodiča > 0,5 mm²
- Najveća duljina: **1200 m**
- Kabele držite podalje od energetskih kabela i električnih polja

## Konfiguracija

### Parametri Modbus komunikacije

Komunikacijski parametri RS-485 su fiksni i na strani izmjenjivača nije ih potrebno konfigurirati:

| Parametar | Vrijednost |
|-----------|-------|
| Brzina prijenosa | 9600 bps |
| Podatkovni bitovi | 8 |
| Paritet | nema |
| Stop bitovi | 1 |
| Slave ID | 1 (zadano, može se postaviti 1–31) |

Kod više izmjenjivača na istoj sabirnici svaki izmjenjivač mora imati jedinstveni Slave ID. Slave ID se postavlja u LCD izborniku izmjenjivača ili u aplikaciji SolarMAN.

## Mogućnosti uređaja

### Praćenje baterije

Predložak prati stanje napunjenosti za do dva baterijska paketa. SOC baterije 1 dostupan je na svim modelima HYD KTL-3PH, a SOC baterije 2 na modelima HYD 10–20KTL-3PH s dva baterijska ulaza.

Svaki od uređaja „SOC baterije 1” i „SOC baterije 2” ima pet servisnih atributa za detaljnu dijagnostiku baterije: temperaturu, napon, struju punjenja/pražnjenja, snagu punjenja/pražnjenja i stanje ispravnosti (SOH).

Dva brojila energije prate dnevno punjenje i pražnjenje baterije u kWh, svaki sa servisnim atributom za ukupnu vrijednost od početka rada.

### Praćenje fotonaponske proizvodnje

Predložak čita izlaznu snagu do tri pojedinačna fotonaponska stringa (PV1, PV2, PV3), svaki sa servisnim atributima za napon i struju stringa. Zajednički uređaj Ukupna fotonaponska snaga prikazuje zbrojenu snagu svih stringova.

Dva brojila energije prate fotonaponsku proizvodnju: dnevnu i ukupnu od početka rada, u kWh.

### Energija mreže i trošila

Tri brojila energije daju dnevna očitanja razmjene s mrežom i potrošnje trošila:
- **Energija preuzeta iz mreže danas** — energija kupljena iz mreže (kWh)
- **Energija predana u mrežu danas** — energija prodana u mrežu (kWh)
- **Potrošnja trošila danas** — ukupna potrošnja trošila (kWh)

Svako dnevno brojilo ima servisni atribut s ukupnom vrijednošću od početka rada.

### Praćenje AC izlaza

Predložak ima tri uređaja za napon po fazama (faza R/S/T, odgovara L1/L2/L3), svaki sa servisnim atributom za struju faze. Frekvencija mreže javlja se u Hz.

Dva uređaja snage prate izlaz izmjenjivača na različitim mjernim točkama:
- **Ukupna izlazna djelatna snaga** — izlazna snaga izmjenjivača u kW, sa servisnim atributima za jalovu snagu (kVAR) i prividnu snagu (kVA)
- **Ukupna djelatna snaga PCC** — snaga u točki zajedničkog priključka (Point of Common Coupling, mjesto priključka na mrežu) u kW, sa servisnim atributima za jalovu i prividnu snagu. To se mjerenje koristi za ograničenje predaje u mrežu i funkcije regulatora elektrane.

### Servisni atributi modula

Modul ima tri servisna atributa za dijagnostiku izmjenjivača:
- **Šifra proizvoda** — identifikacija proizvoda izmjenjivača
- **Stanje sustava** — trenutačno radno stanje: Waiting, Detection, Grid-connected, Emergency power supply, Recoverable fault, Permanent fault, Upgrade ili Self-charging
- **Temperatura okoline** — unutarnja temperatura izmjenjivača u °C

Skripta ReadScript modula prati i tri registra s bitovnim maskama kvarova (H:0x0405–H:0x0407) te kvarove zaštite mreže, greške uzorkovanja i hardverske kvarove javlja kao greške u sustavu TapHome.

### Dodatne mogućnosti

Izmjenjivači HYD KTL-3PH imaju i registre za daljinsko uključivanje i isključivanje, odabir načina pohrane energije (Self-use, Time-of-Use, Timing, Passive, Peak Shaving, Off-grid) i pasivno upravljanje punjenjem i pražnjenjem baterije za vanjske sustave upravljanja energijom. Preko Modbusa su dostupni i djelatna snaga i faktor snage po fazama, praćenje izlaza off-grid/EPS, dodatni ulazi fotonaponskih stringova (PV4+), broj ciklusa baterije, temperatura hladnjaka i parametri baterija 3–6. Mogu se dodati u budućem ažuriranju predloška.

> [!TIP]
> Registri pasivnog načina (H:0x1110 i H:0x1187) omogućuju vanjsko Modbus upravljanje snagom punjenja i pražnjenja baterije. To je posebno korisno za smart rules u sustavu TapHome kojima se provode strategije upravljanja energijom, npr. punjenje baterija u razdobljima niske tarife.

## Rješavanje problema

### Nema Modbus komunikacije

1. Provjerite je li kabel RS-485 spojen na **pinove 1+3** (ili 2+4) priključka COM, a ne na pinove 5+6 (sabirnica pametnog brojila)
2. Provjerite polaritet kabela: pin 1 (A+) na A+ sustava TapHome, pin 3 (B-) na B- sustava TapHome
3. Provjerite je li TapHome postavljen na 9600 baud, bez pariteta, 1 stop bit
4. Provjerite podudara li se Slave ID na izmjenjivaču i u sustavu TapHome
5. Provjerite zaključni otpornik od 120 Ω na prvom i posljednjem uređaju na sabirnici

### Povremene greške u komunikaciji

1. Provjerite je li kabel RS-485 oklopljena upredena parica s presjekom bakrenog vodiča > 0,5 mm²
2. Kabele RS-485 držite podalje od energetskih kabela i DC ožičenja
3. Provjerite da ukupna duljina sabirnice ne prelazi 1200 m
4. Provjerite da na sabirnici nema dvostrukih Slave ID-jeva

### Stanje sustava pokazuje kvar

1. U servisnom atributu Stanje sustava provjerite konkretni kod stanja (4 = Recoverable fault, 5 = Permanent fault)
2. Pregledajte pojedinosti registara kvarova u servisnoj dijagnostici sustava TapHome: predložak čita tri registra s bitovnim maskama kvarova koji obuhvaćaju zaštitu mreže, greške uzorkovanja i hardverske kvarove
3. Detaljne kodove grešaka potražite na LCD zaslonu izmjenjivača ili u aplikaciji SolarMAN

## Dostupni uređaji 19

Ovi se uređaji pojavljuju u TapHomeu nakon uvoza.

Sofar Solar HYD KTL-3PH Modul

Servisni atributi

|                     |                                                                                                                                                    |
|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------|
| Šifra proizvoda     |                                                                                                                                                    |
| Stanje sustava      | Radno stanje izmjenjivača — Waiting, Detection, Grid-connected, Emergency power supply, Recoverable fault, Permanent fault, Upgrade, Self-charging |
| Temperatura okoline | Unutarnja temperatura izmjenjivača u °C                                                                                                            |

Čitanje (modul)

```taphome
#fault 1
var fault :=MODBUSR(H, 0x0405, Uint16);
IF fault !=0 
IF(GETBIT(fault, 0) != 0, ADDERROR("Grid over-voltage"));
IF(GETBIT(fault, 1) != 0, ADDERROR("Grid undervoltage"));
IF(GETBIT(fault, 2) != 0, ADDERROR("Grid overfrequency"));
IF(GETBIT(fault, 3) != 0, ADDERROR("Grid underfrequency"));
IF(GETBIT(fault, 4) != 0, ADDERROR("Leakage current fault"));
IF(GETBIT(fault, 5) != 0, ADDERROR("High penetration error"));
IF(GETBIT(fault, 6) != 0, ADDERROR("Low penetration error"));
IF(GETBIT(fault, 7) != 0, ADDERROR("Islanding error"));
IF(GETBIT(fault, 8) != 0, ADDERROR("Grid voltage transient value overvoltage 1"));
IF(GETBIT(fault, 9) != 0, ADDERROR("Grid voltage transient value overvoltage 2"));
IF(GETBIT(fault, 10) != 0, ADDERROR("Grid line voltage error"));
IF(GETBIT(fault, 11) != 0, ADDERROR("Inverter voltage error"));
IF(GETBIT(fault, 12) != 0, ADDERROR("Anti-backflow overload"));
END

#fault 2
fault :=MODBUSR(H, 0x0406, Uint16);
IF fault !=0 
IF(GETBIT(fault, 0) != 0, ADDERROR("Grid current sampling error"));
IF(GETBIT(fault, 1) != 0, ADDERROR("Grid current DC component sampling error (AC side)"));
IF(GETBIT(fault, 2) != 0, ADDERROR("Grid voltage sampling error (DC side)"));
IF(GETBIT(fault, 3) != 0, ADDERROR("Grid voltage sampling error (AC side)"));
IF(GETBIT(fault, 4) != 0, ADDERROR("Leakage current sampling error (DC side)"));
IF(GETBIT(fault, 5) != 0, ADDERROR("Leakage current sampling error (AC side)"));
IF(GETBIT(fault, 6) != 0, ADDERROR("Load voltage DC component sampling error"));
IF(GETBIT(fault, 7) != 0, ADDERROR("DC input current sampling error"));
IF(GETBIT(fault, 8) != 0, ADDERROR("DC component sampling error of grid current (DC side)"));
IF(GETBIT(fault, 9) != 0, ADDERROR("DC input branch current sampling error"));
IF(GETBIT(fault, 12) != 0, ADDERROR("Leakage current consistency error"));
IF(GETBIT(fault, 13) != 0, ADDERROR("Grid voltage consistency error"));
IF(GETBIT(fault, 14) != 0, ADDERROR("DCI consistency error"));
END

#fault 3
fault :=MODBUSR(H, 0x0407, Uint16);
IF fault !=0 
IF(GETBIT(fault, 0) != 0, ADDERROR("SPI communication error (DC side)"));
IF(GETBIT(fault, 1) != 0, ADDERROR("SPI communication error (AC side)"));
IF(GETBIT(fault, 2) != 0, ADDERROR("Chip error (DC side)"));
IF(GETBIT(fault, 3) != 0, ADDERROR("Chip error (AC side)"));
IF(GETBIT(fault, 4) != 0, ADDERROR("Auxiliary power error"));
IF(GETBIT(fault, 5) != 0, ADDERROR("Inverter soft start failure"));
IF(GETBIT(fault, 8) != 0, ADDERROR("Relay detection failure"));
IF(GETBIT(fault, 9) != 0, ADDERROR("Low insulation impedance"));
IF(GETBIT(fault, 10) != 0, ADDERROR("Grounding error"));
IF(GETBIT(fault, 11) != 0, ADDERROR("Input mode setting error"));
IF(GETBIT(fault, 12) != 0, ADDERROR("CT error"));
IF(GETBIT(fault, 13) != 0, ADDERROR("Input reversal error"));
IF(GETBIT(fault, 14) != 0, ADDERROR("Parallel error"));
IF(GETBIT(fault, 15) != 0, ADDERROR("Serial number error"));
END
```

Servisni atributi

Product Code

```taphome
MODBUSR(H, 0x2000, Uint16);
```

System State

```taphome
SWITCH(MODBUSR(H, 0x0404, Uint16),
0, "Waiting",
1, "Detection",
2, "Grid-connected",
3, "Emergency power supply",
4, "Recoverable fault",
5, "Permanent fault",
6, "Upgrade",
7, "Self-charging",
"Fault")
```

Ambient Temperature

```taphome
MODBUSR(H, 0x0418, Int16) + "°C";
```

SOC baterije 1 Analogni ulaz Samo za čitanje

Stanje napunjenosti baterije 1 u postocima — uključuje servisne atribute za temperaturu, napon, struju, snagu i SOH

Registar: H:0x0608 Uint16 Jedinica: % numeric

Servisni atributi

|             |
|-------------|
| Temperatura |
| Napon       |
| Struja      |
| Snaga       |
| SOH         |

Čitanje razine ulaza

```taphome
MODBUSR(H, 0x0608, Uint16)
```

Servisni atributi

Temperature

```taphome
MODBUSR(H, 0x0607, Int16) + "°C";
```

Voltage

```taphome
MODBUSR(H, 0x0604, Uint16) + " V";
```

Current

```taphome
MODBUSR(H, 0x0605, Int16)/100 + " A";
```

Power

```taphome
MODBUSR(H, 0x0606, Int16)/100 + " kW";
```

SOH

```taphome
MODBUSR(H, 0x0609, Uint16) + " %";
```

SOC baterije 2 Analogni ulaz Samo za čitanje

Stanje napunjenosti baterije 2 u postocima — dostupno na modelima HYD 10–20KTL-3PH s dva baterijska ulaza

Registar: H:0x060F Uint16 Jedinica: % numeric

Servisni atributi

|             |
|-------------|
| Temperatura |
| Napon       |
| Struja      |
| Snaga       |
| SOH         |

Čitanje razine ulaza

```taphome
MODBUSR(H, 0x060F, uint16)
```

Servisni atributi

Temperature

```taphome
MODBUSR(H, 0x060E, Int16) + " °C";
```

Voltage

```taphome
MODBUSR(H, 0x060B, Uint16) + " V";
```

Current

```taphome
MODBUSR(H, 0x060C, Int16) + " A";
```

Power

```taphome
MODBUSR(H, 0x060D, Int16) + " kW";
```

SOH

```taphome
MODBUSR(H, 0x0610, Uint16) + " %";
```

Pražnjenje baterije danas Varijabla Samo za čitanje

Dnevna energija pražnjenja baterije u kWh — uključuje ukupnu vrijednost od početka rada

Registar: H:0x0698 Uint32 Jedinica: kWh numeric

Servisni atributi

|                            |
|----------------------------|
| Ukupno pražnjenje baterije |

Čitanje

```taphome
MODBUSR(H, 0x0698, Uint32)/100
```

Servisni atributi

Battery Discharge Total

```taphome
MODBUSR(H, 0x069A, Uint32)/10
```

Punjenje baterije danas Varijabla Samo za čitanje

Dnevna energija punjenja baterije u kWh — uključuje ukupnu vrijednost od početka rada

Registar: H:0x0694 Uint32 Jedinica: kWh numeric

Servisni atributi

|                          |
|--------------------------|
| Ukupno punjenje baterije |

Čitanje

```taphome
MODBUSR(H, 0x0694, Uint32)/100
```

Servisni atributi

Battery Charge Total

```taphome
MODBUSR(H, 0x0696, Uint32)/10
```

Energija preuzeta iz mreže danas Varijabla Samo za čitanje

Dnevna energija kupljena iz mreže u kWh — uključuje ukupnu vrijednost od početka rada

Registar: H:0x068C Uint32 Jedinica: kWh numeric

Servisni atributi

|                                   |
|-----------------------------------|
| Ukupna energija preuzeta iz mreže |

Čitanje

```taphome
MODBUSR(H, 0x068C, Uint32)/100
```

Servisni atributi

Energy Purchase Total

```taphome
MODBUSR(H, 0x068E, Uint32)/10 + " kWh"
```

Energija predana u mrežu danas Varijabla Samo za čitanje

Dnevna energija prodana u mrežu u kWh — uključuje ukupnu vrijednost od početka rada

Registar: H:0x0690 Uint32 Jedinica: kWh numeric

Servisni atributi

|                                 |
|---------------------------------|
| Ukupna energija predana u mrežu |

Čitanje

```taphome
MODBUSR(H, 0x0690, Uint32)/100
```

Servisni atributi

Energy Selling Total

```taphome
MODBUSR(H, 0x0692, Uint32)/10
```

Frekvencija mreže Varijabla Samo za čitanje

Registar: H:0x0484 UInt16 Jedinica: Hz numeric

Čitanje

```taphome
MODBUSR(H, 0x484, UInt16)/100
```

Potrošnja trošila danas Varijabla Samo za čitanje

Dnevna potrošnja trošila u kWh — uključuje ukupnu vrijednost od početka rada

Registar: H:0x0688 Int32 Jedinica: kWh numeric

Servisni atributi

|                          |
|--------------------------|
| Ukupna potrošnja trošila |

Čitanje

```taphome
MODBUSR(H, 0x0688, Int32)/100
```

Servisni atributi

Load Consumption Total

```taphome
MODBUSR(H, 0x068A, Int32)/100 + "kWh"
```

Ukupna fotonaponska snaga Varijabla Samo za čitanje

Zbrojena izlazna snaga svih fotonaponskih stringova u kW

Registar: H:0x05C4 Uint16 Jedinica: kW numeric

Čitanje

```taphome
MODBUSR(H, 0x05C4, Uint16)/10
```

Snaga PV1 Varijabla Samo za čitanje

Registar: H:0x0586 Uint16 Jedinica: kW numeric

Servisni atributi

|        |
|--------|
| Napon  |
| Struja |

Čitanje

```taphome
MODBUSR(H, 0x0586, Uint16)/100
```

Servisni atributi

Voltage

```taphome
MODBUSR(H, 0x0584, Uint16)/10 + " V";
```

Current

```taphome
MODBUSR(H, 0x0585, Uint16)/100 + " A";
```

Snaga PV2 Varijabla Samo za čitanje

Registar: H:0x0589 Uint16 Jedinica: kW numeric

Servisni atributi

|        |
|--------|
| Napon  |
| Struja |

Čitanje

```taphome
MODBUSR(H, 0x0589, Uint16)/100
```

Servisni atributi

Voltage

```taphome
MODBUSR(H, 0x0587, Uint16)/10 + " V";
```

Current

```taphome
MODBUSR(H, 0x0588, Uint16)/100 + " A";
```

Snaga PV3 Varijabla Samo za čitanje

Registar: H:0x058A Uint16 Jedinica: kW numeric

Servisni atributi

|        |
|--------|
| Napon  |
| Struja |

Čitanje

```taphome
MODBUSR(H, 0x058A, Uint16)/100
```

Servisni atributi

Voltage

```taphome
MODBUSR(H, 0x058A, Uint16)/10 + " V";
```

Current

```taphome
MODBUSR(H, 0x058B, Uint16)/100 + " A"
```

Fotonaponska proizvodnja danas Varijabla Samo za čitanje

Dnevna energija fotonaponske proizvodnje u kWh

Registar: H:0x0684 Int32 Jedinica: kWh numeric

Čitanje

```taphome
MODBUSR(H, 0x0684, Int32)/100
```

Ukupna fotonaponska proizvodnja Varijabla Samo za čitanje

Energija fotonaponske proizvodnje od početka rada u kWh

Registar: H:0x0686 Int32 Jedinica: kWh numeric

Čitanje

```taphome
MODBUSR(H, 0x0686, Int32)/100
```

Napon faze R Varijabla Samo za čitanje

Mrežni napon faze L1/R u V — uključuje servisni atribut struje faze

Registar: H:0x048D Uint16 Jedinica: V numeric

Servisni atributi

|          |
|----------|
| Struja R |

Čitanje

```taphome
MODBUSR(H, 0x048D, Uint16)/10
```

Servisni atributi

Current R

```taphome
MODBUSR(H, 0x048E, Uint16)/100 + " A";
```

Napon faze S Varijabla Samo za čitanje

Mrežni napon faze L2/S u V — uključuje servisni atribut struje faze

Registar: H:0x0498 Uint16 Jedinica: V numeric

Servisni atributi

|          |
|----------|
| Struja S |

Čitanje

```taphome
MODBUSR(H, 0x0498, Uint16)/10
```

Servisni atributi

Current S

```taphome
MODBUSR(H, 0x0499, Uint16)/100 + " A"
```

Napon faze T Varijabla Samo za čitanje

Mrežni napon faze L3/T u V — uključuje servisni atribut struje faze

Registar: H:0x04A3 Uint16 Jedinica: V numeric

Servisni atributi

|          |
|----------|
| Struja T |

Čitanje

```taphome
MODBUSR(H, 0x04A3, Uint16)/10
```

Servisni atributi

Current T

```taphome
MODBUSR(H, 0x04A4, Uint16)/100 + " A"
```

Ukupna izlazna djelatna snaga Varijabla Samo za čitanje

Ukupna izlazna djelatna snaga izmjenjivača u kW — uključuje jalovu i prividnu snagu

Registar: H:0x0485 Int16 Jedinica: kW numeric

Servisni atributi

|                        |
|------------------------|
| Izlazna jalova snaga   |
| Izlazna prividna snaga |

Čitanje

```taphome
MODBUSR(H, 0x0485, Int16)/100
```

Servisni atributi

Reactive Power Output

```taphome
MODBUSR(H, 0x0486, Int16)/100 + " kW" ;
```

Apparent Power Output

```taphome
MODBUSR(H, 0x0487, Int16)/100 + " kW" ;
```

Ukupna djelatna snaga PPC Varijabla Samo za čitanje

Djelatna snaga u točki zajedničkog priključka (mjesto priključka na mrežu) u kW — koristi se za ograničenje predaje u mrežu

Registar: H:0x0488 Int16 Jedinica: kW numeric

Servisni atributi

|                    |
|--------------------|
| Jalova snaga PPC   |
| Prividna snaga PPC |

Čitanje

```taphome
MODBUSR(H, 0x0488, Int16)/100
```

Servisni atributi

Reactive Power PPC

```taphome
MODBUSR(H, 0x0489, Int16)/100 + " kW" ;
```

Apparent Power PPC

```taphome
MODBUSR(H, 0x048A, Int16)/100 + " kW" ;
```

**Povezivanje:** Modbus RTU • 9600 baud• 8N1 • Slave ID: $\[SlaveId]

Moguća poboljšanja (12)

- H:0x1104 Remote Switch On/Off — Remote inverter on/off control — useful for TapHome automation
- H:0x1110 Energy Storage Mode — Operating mode selection: Self-use, Time-of-Use, Timing, Passive, Peak Shaving, Off-grid
- H:0x1187 Passive Battery Charge/Discharge — S32, external Modbus control of battery charge/discharge power — enables TapHome smart rule energy management
- H:0x0200 Running State — 0=Wait, 1=CheckState, 2=Normal, 3=CheckDischarge, 4=Discharge, 5=EPS, 6=Fault, 7=Permanent — older register range, covered by H:0x0404 System State in module
- H:0x0504 Off-Grid Active Power — EPS/backup output power (S16, 0.01 kW) — relevant for off-grid/backup scenarios
- H:0x050A-0x0522 Off-Grid Per-Phase Voltage/Current/Power — L1/L2/L3 off-grid output monitoring — 9 registers for 3-phase EPS output
- H:0x0507 Off-Grid Frequency — EPS output frequency (U16, 0.01 Hz)
- H:0x048F-0x04A7 Per-Phase Active/Reactive Power and Power Factor — L1/L2/L3 individual active power, reactive power, and power factor — template only reads voltage+current per phase
- H:0x058D-0x058F PV4 Voltage/Current/Power — PV string 4 input — template supports up to PV3. HA integration supports up to PV10
- H:0x0612-0x0627 Battery 3–6 Parameters — Additional battery packs (voltage, current, power, temperature, SOC, SOH, cycles) — template supports battery 1–2 only
- H:0x022C Battery Cycle Count — Battery cycle times (Uint16, 0–65536) — available at 0x060A per battery in HA integration
- H:0x0419 Heatsink Temperature — Inverter heatsink temperature (S16, °C) — template reads inner temperature (0x0418) only

## Parametri uvoza

Ove vrijednosti unosite pri uvozu XML-a.

| Pitanje u aplikaciji | Zadano        |
|----------------------|---------------|
| Slave ID             | `1`           |
| IP adresa            | `192.168.1.0` |

## Izvori

- SOFARSOLAR ModBus-RTU Communication Protocol
  
  [community.openenergymonitor.org](https://community.openenergymonitor.org/uploads/short-url/dF8j79PsvtCS0xQ5aPxHXO4HZDE.pdf) 2026-03-28
  
  [PDF](https://taphome.com/compatibility/devices/sofarsolar-inverter-3p/manufacturer/sofarsolar-modbus-rtu-protocol.pdf)
- HYD 5/6/8/10/15/20KTL-3PH User Manual
  
  [www.sofarsolar.com](https://www.sofarsolar.com/upload/file/20240321/1710982866939025487.pdf) 2026-03-28
  
  [PDF](https://taphome.com/compatibility/devices/sofarsolar-inverter-3p/manufacturer/hyd-5-20ktl-3ph-user-manual.pdf)
- Home Assistant SolaX/Sofar Modbus Integration
  
  [github.com](https://github.com/wills106/homeassistant-solax-modbus) 2026-03-28

Dokumenti proizvođača zaštićeni su autorskim pravom (©) svojih vlasnika. Dostupni su onako kako ih je proizvođač objavio, samo za informaciju.

## Povezana dokumentacija

- [Modbus Integration](https://taphome.com/hr/compatibility/modbus-guide/)
- [Modbus](https://taphome.com/hr/docs/integration/modbus/)
- [Jednostavna konfiguracija pomoću predložaka](https://taphome.com/hr/docs/integration/modbus/templates/)
- [Skripte Modbus i prefetch](https://taphome.com/hr/docs/script/modbus-scripts/)
- [Funkcije Modbus](https://taphome.com/hr/docs/script/modbus/)
- [Tipovi podataka Modbus](https://taphome.com/hr/docs/script/modbus-data-types/)