title: "Shelly 2PM Gen3"
description: "Dvokanalni relej s mjerenjem snage ili upravljanje roletom i žaluzinom preko HTTP RPC API-ja. Integracija Shelly 2PM Gen3 za TapHome uz promjenu profila."
url: "https://taphome.com/hr/compatibility/shelly-2pm-gen3/"
language: hr
lastmod: 2026-03-29
generator: hugo
ai:
  topics: ["http","electric-meter","wifi","relay","power-metering","cover","blind","mdns","profile"]
  questions: ["Kako integrirati Shelly 2PM Gen3 sa sustavom TapHome?","Koja je razlika između profila switch i cover na uređaju Shelly 2PM Gen3?","Kako upravljati motoriziranom žaluzinom pomoću uređaja Shelly 2PM Gen3 i sustava TapHome?","Kako na uređaju Shelly 2PM Gen3 promijeniti relejni način rada u način za rolete i obratno?","Zašto predložak Shelly 2PM Gen3 u sustavu TapHome prikazuje grešku profila?","Kako kalibrirati roletu na uređaju Shelly 2PM Gen3 za upravljanje položajem?"]
---

# Shelly 2PM Gen3

Komunikacija: Packet Parser → HTTP

- [Stranica proizvoda Shelly 2PM Gen3](https://www.shelly.com/en/products/shop/shelly-2-pm-gen3)

> Adresa u mreži
> 
> TapHome komunicira s uređajem na adresi unesenoj pri uvozu. Dodijelite uređaju stalnu adresu — rezervaciju IP adrese u usmjerivaču ili njegovo mDNS ime ako ga podržava — inače integracija prestaje raditi kada usmjerivač promijeni adresu.
> 
> [Priprema mreže](https://taphome.com/hr/docs/setup/network-preparation/)

## Upute za integraciju

Shelly 2PM Gen3 kompaktan je dvokanalni Wi-Fi relejni modul s ugrađenim mjerenjem snage. Stane iza standardnog zidnog prekidača i može upravljati dvama neovisnim strujnim krugovima do 10 A svaki (ukupno 16 A pri 230 V AC) ili jednom motoriziranom roletom ili žaluzinom. TapHome s uređajem komunicira preko HTTP-a pomoću API-ja Gen2+/Gen3 JSON-RPC 2.0 u lokalnoj mreži, veza s oblakom nije potrebna.

Uređaj podržava dva profila rada, **switch** i **cover**, koji se biraju u web-sučelju Shelly ili servisnom radnjom u sustavu TapHome. U profilu switch oba relejna izlaza (O1 i O2) rade neovisno, uz mjerenje snage na svakom kanalu. U profilu cover oba izlaza pogone jedan motor za rolete, žaluzine ili zavjese, s upravljanjem položajem, podrškom za nagib lamela i kalibracijom.

Za razliku od uređaja Shelly 1PM Gen3, koji upravlja jednim strujnim krugom, 2PM Gen3 nudi dvokanalno upravljanje ili podršku za motorizirane rolete. Oba uređaja dijele istu platformu Gen3 s procesorom ESP (8 MB flash memorije), do 6 istodobnih HTTP veza i mogućnošću nadogradnje na Matter.

## Konfiguracija

Shelly 2PM Gen3 spaja se preko Wi-Fi mreže. Pri uvozu predloška TapHome unesite IP adresu uređaja (u predlošku je unaprijed upisan primjer `192.168.0.1`).

> [!WARNING]
> Za integraciju sa sustavom TapHome autentifikacija na uređaju Shelly mora biti **isključena**. TapHome ne podržava HTTP Digest Auth koju koriste uređaji Gen2+/Gen3. Otvorite web-sučelje Shelly (`http://{device-ip}`) → Settings → Authentication i provjerite je li isključena.

> [!NOTE]
> Ako je na uređaju Shelly uključen način rada ECO, zbog kratkih intervala očitavanja u predlošku (2,5–3 sekunde) mogu nastati prekoračenja vremena komunikacije. Ako se veza povremeno prekida, isključite način rada ECO u web-sučelju Shelly.

### Odabir profila

Shelly 2PM Gen3 u jednom trenutku radi u jednom od dva profila. Aktivni profil određuje koji uređaji u sustavu TapHome rade:

- **Profil switch** — uključuje obje relejne sklopke (Sklopka 1 i Sklopka 2) s neovisnim mjerenjem snage. Roleta i žaluzina prikazat će grešku profila.
- **Profil cover** — uključuje roletu i žaluzinu (s nagibom lamela). Sklopke će prikazati grešku profila.

Aktivni profil vidljiv je u sustavu TapHome kao servisni atribut modula („Profil”). Profil promijenite servisnom radnjom **Postavi profil** na razini modula ili u web-sučelju Shelly. Nakon promjene profila uređaj se ponovno pokreće i bez grešaka rade samo uređaji koji odgovaraju novom profilu.

> [!TIP]
> Predložak sadrži sve četiri vrste uređaja (2 sklopke + roleta + žaluzina), ali rade samo uređaji koji odgovaraju aktivnom profilu. Uređaji u pogrešnom profilu prikazuju poruku o grešci kao što je „Profile is not set to switch” ili „Profile is not set to cover”. To je očekivano ponašanje, a ne kvar.

### Kalibracija rolete

Kod profila cover krajnji položaji motora moraju se kalibrirati prije nego što upravljanje položajem počne raditi. Dok kalibracija nije završena, predložak prikazuje grešku „Calibration is required”. Kalibrirajte u web-sučelju Shelly ili servisnom radnjom **Pokreni automatsku kalibraciju** u sustavu TapHome. Tijekom kalibracije roleta se potpuno otvori i potpuno zatvori kako bi se izmjerile duljine hoda.

## Mogućnosti uređaja

### Upravljanje relejem (profil switch)

Predložak daje dvije neovisne relejne sklopke. Svaka sklopka čita stanje iz `/rpc/Switch.GetStatus?id={0,1}` (polje `output`, logička vrijednost) i upravlja relejem preko `/rpc/Switch.Set?id={0,1}&on=true|false`.

Svaka sklopka ima i servisne atribute za praćenje po kanalu:

- **Temperatura** — unutarnja temperatura uređaja u °C (`temperature.tC`)
- **Potrošnja energije** — ukupna energija u Wh (`aenergy.total`)
- **Trenutačna snaga** — snaga u stvarnom vremenu u W (`apower`)
- **Električni napon** — napon napajanja u V (`voltage`)
- **Električna struja** — struja trošila u A (`current`)
- **Frekvencija** — frekvencija izmjenične mreže u Hz (`freq`)
- **Faktor snage** — vrijednost faktora snage (`pf`)

Sklopke se ažuriraju svakih 2,5 sekunde.

### Upravljanje roletom (profil cover)

Uređaj **Roleta** upravlja motoriziranom roletom, zavjesom ili tendom. Položaj čita iz `/rpc/Cover.GetStatus?id=0` (polja `current_pos` i `target_pos`, 0–100), a upisuje ga preko `/rpc/Cover.GoToPosition?id=0&pos=N`. Predložak obrće ljestvicu položaja tako da u sustavu TapHome 0 znači potpuno otvoreno, a 100 potpuno zatvoreno.

Roleta ima servisne atribute:

- **Temperatura** — unutarnja temperatura uređaja u °C
- **Potrošnja energije** — ukupna energija motora u Wh
- **Trenutačna snaga** — snaga motora u stvarnom vremenu u W
- **Električni napon** — napon napajanja u V
- **Električna struja** — struja motora u A

Servisna radnja **Pokreni automatsku kalibraciju** omogućuje pokretanje kalibracije rolete izravno iz sustava TapHome.

### Upravljanje žaluzinom (profil cover)

Uređaj **Žaluzina** proširuje mogućnosti uređaja **Roleta** upravljanjem nagibom lamela za vanjske žaluzine. Osim položaja čita i upisuje i položaj lamela (`slat_pos`) preko `/rpc/Cover.GoToPosition?id=0&pos=N&slat_pos=M`. Obrnute su obje ljestvice, i za položaj i za nagib (u sustavu TapHome 0 = otvoreno, 100 = zatvoreno).

Žaluzina ima iste servisne atribute kao roleta te dodatno:

- **Lamele** — prikazuje je li upravljanje lamelama uključeno ili isključeno (iz `Cover.GetConfig → $.slat.enable`)
- **Vrijeme otvaranja lamela** — postavljeno trajanje otvaranja lamela u sekundama
- **Vrijeme zatvaranja lamela** — postavljeno trajanje zatvaranja lamela u sekundama

> [!NOTE]
> **Poznati problem predloška:** servisni atribut „Vrijeme zatvaranja lamela” čita `$.slat.open_time` umjesto `$.slat.close_time` iz konfiguracije Cover. Oba atributa vremena lamela trenutačno prikazuju istu vrijednost (vrijeme otvaranja). To će se ispraviti u nekoj budućoj reviziji predloška.

Na uređaju žaluzina dostupne su dvije servisne radnje:

- **Pokreni automatsku kalibraciju** — pokreće kalibraciju položaja rolete
- **Postavi lamele** — uključuje upravljanje lamelama i postavlja vremena otvaranja i zatvaranja (svako 0,1–5 sekundi) preko `/rpc/Cover.SetConfig`

> [!WARNING]
> Upravljanje lamelama (nagibom) mora biti uključeno prije nego što uređaj žaluzina može upravljati nagibom. Ako uređaj ne daje položaj lamela, žaluzina prikazuje grešku „Slat position must be enabled for blinds”. Servisnom radnjom **Postavi lamele** uključite ga i postavite trajanje otvaranja i zatvaranja.

### Servisna dijagnostika

Predložak na razini modula daje servisne atribute za praćenje uređaja:

- **Wi-Fi** — naziv spojene mreže (SSID)
- **IP adresa** — trenutačna IP adresa uređaja u mreži
- **Jačina signala** — Wi-Fi RSSI u dB
- **MAC** — MAC adresa uređaja
- **Profil** — trenutačno aktivan profil uređaja (switch ili cover)

Skripta za čitanje modula provjerava i dostupna ažuriranja firmvera i potrebu za ponovnim pokretanjem te ih prikazuje kao upozorenja u sučelju TapHome.

### Servisne radnje

Na razini modula dostupne su tri servisne radnje:

- **Ažuriraj firmver** — pokreće ažuriranje firmvera na najnovije stabilno izdanje preko `/rpc/Shelly.Update`
- **Ponovno pokretanje** — ponovno pokreće uređaj preko `/rpc/Shelly.Reboot`
- **Postavi profil** — prebacuje između načina rada cover i switch preko `/rpc/Shelly.SetProfile`

### Dodatne mogućnosti

Shelly 2PM Gen3 u svojim RPC odgovorima daje i stanja fizičkih ulaza (`input:0`, `input:1`), brojače vraćene/predane energije, vrijeme rada uređaja, zauzeće RAM-a i vrijeme uređaja. Timer za automatsko isključivanje dostupan je preko parametra `toggle_after`, zaštita od prekoračenja snage može se postaviti preko `Switch.SetConfig → power_limit`, a brojači energije mogu se poništiti preko `/rpc/Switch.ResetCounters`. U načinu rada cover dostupne su izravne naredbe za otvaranje, zatvaranje i zaustavljanje te stanje kretanja rolete (open/opening/closed/closing/stopped/calibrating). Te se mogućnosti mogu dodati u nekom budućem ažuriranju predloška.

## Rješavanje problema

### Uređaj ne odgovara

1. Provjerite je li Shelly spojen na Wi-Fi i ima li valjanu IP adresu
2. Umjesto IP adrese pokušajte koristiti mDNS naziv hosta (`shelly2pmg3-AABBCCDDEE.local`), jer se IP adresa možda promijenila nakon obnove DHCP zakupa
3. U pregledniku otvorite `http://{device-ip}/rpc/Shelly.GetDeviceInfo`. Ako odgovori u formatu JSON, uređaj je dostupan
4. Provjerite jesu li TapHome Core i Shelly u istoj mreži / VLAN-u
5. Provjerite je li autentifikacija na uređaju Shelly isključena

### Greške neusklađenog profila

Ako uređaj prikazuje „Profile is not set to switch” ili „Profile is not set to cover”:

1. Provjerite koji je profil trenutačno aktivan: servisni atribut „Profil” na razini modula prikazuje trenutačni način rada
2. Prebacite na ispravan profil servisnom radnjom **Postavi profil** ili uklonite nekorištene uređaje iz sustava TapHome
3. Nakon promjene profila uređaj se automatski ponovno pokreće, pa pričekajte nekoliko sekundi da se veza ponovno uspostavi

### Upravljanje položajem rolete ne radi

1. Provjerite je li uređaj u profilu cover, jer profil switch ne nudi funkcije rolete
2. Pokrenite servisnu radnju **Pokreni automatsku kalibraciju**, jer upravljanje položajem zahtijeva završenu kalibraciju
3. Provjerite je li motor ispravno spojen na stezaljke O1 i O2
4. Ručno očitajte `/rpc/Cover.GetStatus?id=0` i provjerite je li `pos_control` `true`

### Nagib žaluzine ne reagira

1. Provjerite je li upravljanje lamelama uključeno: servisni atribut „Lamele” treba prikazivati „Enabled”
2. Ako je isključeno, servisnom radnjom **Postavi lamele** uključite ga i postavite vremena otvaranja i zatvaranja
3. Provjerite podržava li motor žaluzine nagib, jer rolete bez nagiba zanemaruju naredbe za lamele

### Upozorenje o pregrijavanju

Shelly 2PM Gen3 ima unutarnju toplinsku zaštitu. Ako temperatura uređaja prijeđe sigurnosne granice, očitanje `temperature` u servisnim atributima uređaja raste. Osigurajte dovoljno prozračivanja oko uređaja, osobito pri dugotrajnom sklapanju velikih opterećenja. Najveća sklopna struja je 10 A po kanalu, ukupno 16 A (vršno 18 A).

> [!WARNING]
> Uređaji Shelly Gen2+/Gen3 podržavaju do **6 istodobnih HTTP veza**. Iako je to znatno poboljšanje u odnosu na Gen1 (2 veze), izbjegavajte istodobno očitavanje iz previše sustava (TapHome, Home Assistant, vlastite skripte) kako se ne bi potrošile sve dostupne veze. Predložak Shelly 2PM Gen3 u jednom ciklusu očitavanja koristi do 4 istodobne krajnje točke, pa ostaje malo prostora za dodatne veze.

## Kako ga instalirati u TapHome

### Preduvjeti

- Uređaj Shelly ugrađen i uključen
- Lokalna Wi-Fi mreža (2,4 GHz)
- TapHome CCU u istoj mreži

### Korak 1 — Spojite Shelly na Wi-Fi

**Opcija A — aplikacija Shelly (preporučeno):**

1. Preuzmite [aplikaciju Shelly](https://www.shelly.com/en/support/shelly-app) (iOS / Android)
2. Dodirnite **+** → **Add Device** i slijedite čarobnjak za uparivanje preko Bluetootha
3. Kada se to zatraži, unesite podatke za prijavu na Wi-Fi

**Opcija B — način rada AP (bez aplikacije):**

1. Pri prvom uključivanju uređaj stvara pristupnu točku: `ShellyXXX-AABBCCDDEE`
2. Spojite telefon ili računalo na tu pristupnu točku
3. Otvorite `http://192.168.33.1` → **Internet & Security** → **Wi-Fi Mode - Client**
4. Unesite SSID i lozinku → **Save**

> [!NOTE]
> Shelly podržava samo mreže od **2,4 GHz**. Mreže od 5 GHz neće se prikazati pri skeniranju.

### Korak 2 — Pronađite adresu uređaja

Uređaji Shelly Gen1 podržavaju **mDNS** (Zeroconf). Uređaju možete pristupiti preko naziva hosta umjesto IP adrese:

```
shelly<model>-<MAC>.local
```

Na primjer: `shelly1pm-AABBCCDDEE.local` (MAC adresa velikim slovima u heksadecimalnom zapisu, bez dvotočaka).

> [!TIP]
> **Preporučeno: koristite IP skener TapHome.** Otvorite aplikaciju TapHome i pokrenite **IP skener** (Postavke → Mreža → Skeniranje). Skener pronalazi uređaje u vašoj mreži i prikazuje IP adresu i mDNS naziv hosta. Za pouzdaniju vezu koristite **naziv hosta** umjesto IP adrese, jer ostaje isti i kada se IP adresa uređaja promijeni nakon ponovnog pokretanja usmjerivača.

**Drugi načini** za pronalaženje IP adrese:

- **Aplikacija Shelly:** detalji uređaja → **Device info** → IP adresa
- **Web-sučelje Shelly:** spojite se na AP uređaja prije postavljanja Wi-Fi mreže — IP adresa prikazuje se nakon spremanja
- **DHCP tablica usmjerivača:** potražite naziv hosta poput `shelly1pm-AABBCCDDEE`

### Korak 3 — Konfiguracija u sustavu TapHome

1. U sustavu TapHome dodajte novi modul **Packet Parser (HTTP)**
2. **Adresa:** unesite mDNS naziv hosta (npr. `shelly1pm-AABBCCDDEE.local`) ili IP adresu iz koraka 2
3. **Port:** `80` (zadano, nije potrebno mijenjati)
4. Uvezite predložak — TapHome će čitati `/status` kako bi očitao stanje uređaja

> [!NOTE]
> HTTP autentifikacija na uređajima Shelly zadano je isključena. Ako ste uključili zaštitu prijavom, TapHome trenutačno ne podržava HTTP Basic Auth — za integraciju sa sustavom TapHome ostavite autentifikaciju isključenom.

## Dostupni uređaji 4

Ovi se uređaji pojavljuju u TapHomeu nakon uvoza.

Shelly 2PM Gen3 Modul

Servisni atributi

|                |                                                                                             |
|----------------|---------------------------------------------------------------------------------------------|
| Wi-Fi          |                                                                                             |
| IP adresa      |                                                                                             |
| Jačina signala |                                                                                             |
| MAC            |                                                                                             |
| Profil         | Aktivni profil uređaja — switch (dvokanalni relej) ili cover (motorizirana žaluzina/roleta) |

Servisne radnje

|                    |                                                                                                |
|--------------------|------------------------------------------------------------------------------------------------|
| Ažuriraj firmver   |                                                                                                |
| Ponovno pokretanje |                                                                                                |
| Postavi profil     | Prebacuje između načina rada cover i switch — uređaj se nakon promjene profila ponovno pokreće |

Prilagođene varijable

Čitanje (modul)

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Sys.GetStatus");
IF response.IsSuccess
    Sys.GetStatus := response.Content;
END

response := SENDHTTPREQUEST("/rpc/Sys.GetConfig");
IF response.IsSuccess
    Sys.GetConfig := response.Content;
END

response := SENDHTTPREQUEST("/rpc/WiFi.GetStatus");
IF response.IsSuccess
    WiFi.GetStatus := response.Content;
END

if ! ISNULL(parsejson(Sys.GetStatus, "available_updates.stable", true))
    addwarning("New firmware update is available");
end

if parsejson(Sys.GetStatus, "restart_required", true)
    addwarning("Restart required");
end
```

Servisni atributi

Wifi

```taphome
PARSEJSON(WiFi.GetStatus, "ssid")
```

${ipAddress}

```taphome
PARSEJSON(WiFi.GetStatus, "sta_ip")
```

${xml\_signal\_strength} \[dB]

```taphome
PARSEJSON(WiFi.GetStatus, "rssi")
```

MAC

```taphome
PARSEJSON(Sys.GetStatus, "mac")
```

Profile

```taphome
PARSEJSON(Sys.GetConfig, "$.device.profile");
```

Servisne radnje

${xml\_update\_fw}

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Shelly.Update?stage=\"stable\"");
IF response.IsSuccess
    return("OK");
else
    return("Error");
END

```

${restart}

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Shelly.Reboot");
IF response.IsSuccess
    return("OK");
else
    return("Error");
END
```

Set Profile

Parametri: Profile

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Shelly.SetProfile?name=\"" + 
switch(prof,
0, "cover",
1, "switch",
"")
+ "\"");
IF response.IsSuccess
    return("OK");
else
    return("Error");
END
```

Sklopka 1 Sklopka Čitanje i pisanje

Relejni izlaz 1 s mjerenjem snage po kanalu — zahtijeva profil switch

boolean

Vrijednosti / stanja: ON · OFF

Čitanje stanja sklopke

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Switch.GetStatus?id=" + ID);
IF response.IsSuccess
    Switch.GetStatus := response.Content;  
END
return(PARSEJSON(Switch.GetStatus, "$.output", true));
```

Zapis stanja sklopke

```taphome
VAR response := SENDHTTPREQUEST("rpc/Switch.Set?id=" + ID + "&on=" + if(St,"true","false"));
IF response.IsSuccess = false
  ADDERROR(response.StatusCode);
END
```

Čitanje (modul)

```taphome
if PARSEJSON(Sys.GetConfig, "$.device.profile") != "switch"
	adderror("Profile is not set to switch (" + PARSEJSON(Sys.GetConfig, "$.device.profile") + ")");
end

VAR response := SENDHTTPREQUEST("/rpc/Switch.GetStatus?id=" + ID);
IF response.IsSuccess
    Switch.GetStatus := response.Content;  
END

response := SENDHTTPREQUEST("/rpc/Switch.GetConfig?id=" + ID);
IF response.IsSuccess
    Switch.GetConfig := response.Content;
END

if ! ISNULL(parsejson(Switch.GetStatus, "errors", true))
    adderror("Error: " + parsejson(Switch.GetStatus, "errors"));
end
```

Servisni atributi

${device\_variable\_realtemperature} \[°C]

```taphome
parsejson(Switch.GetStatus, "$.temperature.tC", true)
```

${device\_variable\_electricityconsumption} \[Wh]

```taphome
parsejson(Switch.GetStatus, "$.aenergy.total", true)
```

${device\_variable\_electricitydemand} \[W]

```taphome
parsejson(Switch.GetStatus, "$.apower", true)
```

${valueLogType\_ElectricVoltage} \[V]

```taphome
parsejson(Switch.GetStatus, "$.voltage", true)
```

${valueLogType\_ElectricCurrent} \[A]

```taphome
parsejson(Switch.GetStatus, "$.current", true)
```

${frequency} \[Hz]

```taphome
parsejson(Switch.GetStatus, "$.freq", true)
```

Power Factor

```taphome
parsejson(Switch.GetStatus, "$.pf", true)
```

Sklopka 2 Sklopka Čitanje i pisanje

Relejni izlaz 2 s mjerenjem snage po kanalu — zahtijeva profil switch

boolean

Vrijednosti / stanja: ON · OFF

Čitanje stanja sklopke

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Switch.GetStatus?id=" + ID);
IF response.IsSuccess
    Switch.GetStatus := response.Content;  
END
return(PARSEJSON(Switch.GetStatus, "$.output", true));
```

Zapis stanja sklopke

```taphome
VAR response := SENDHTTPREQUEST("rpc/Switch.Set?id=" + ID + "&on=" + if(St,"true","false"));
IF response.IsSuccess = false
  ADDERROR(response.StatusCode);
END
```

Čitanje (modul)

```taphome
if PARSEJSON(Sys.GetConfig, "$.device.profile") != "switch"
	adderror("Profile is not set to switch (" + PARSEJSON(Sys.GetConfig, "$.device.profile") + ")");
end

VAR response := SENDHTTPREQUEST("/rpc/Switch.GetStatus?id=" + ID);
IF response.IsSuccess
    Switch.GetStatus := response.Content;  
END

response := SENDHTTPREQUEST("/rpc/Switch.GetConfig?id=" + ID);
IF response.IsSuccess
    Switch.GetConfig := response.Content;
END

if ! ISNULL(parsejson(Switch.GetStatus, "errors", true))
    adderror("Error: " + parsejson(Switch.GetStatus, "errors"));
end
```

Servisni atributi

${device\_variable\_realtemperature} \[°C]

```taphome
parsejson(Switch.GetStatus, "$.temperature.tC", true)
```

${device\_variable\_electricityconsumption} \[Wh]

```taphome
parsejson(Switch.GetStatus, "$.aenergy.total", true)
```

${device\_variable\_electricitydemand} \[W]

```taphome
parsejson(Switch.GetStatus, "$.apower", true)
```

${valueLogType\_ElectricVoltage} \[V]

```taphome
parsejson(Switch.GetStatus, "$.voltage", true)
```

${valueLogType\_ElectricCurrent} \[A]

```taphome
parsejson(Switch.GetStatus, "$.current", true)
```

${frequency} \[Hz]

```taphome
parsejson(Switch.GetStatus, "$.freq", true)
```

Power Factor

```taphome
parsejson(Switch.GetStatus, "$.pf", true)
```

Roleta Roleta Čitanje i pisanje

Motorizirana roleta ili zavjesa s upravljanjem položajem — zahtijeva profil cover i kalibraciju

numeric Jedinica: %

Servisni atributi

|                    |
|--------------------|
| Temperatura        |
| Potrošnja energije |
| Trenutačna snaga   |
| Električni napon   |
| Električna struja  |

Servisne radnje

|                                |
|--------------------------------|
| Pokreni automatsku kalibraciju |

Čitanje (modul)

```taphome
if PARSEJSON(Sys.GetConfig, "$.device.profile") != "cover"
	adderror("Profile is not set to cover (" + PARSEJSON(Sys.GetConfig, "$.device.profile") + ")");
end

VAR response := SENDHTTPREQUEST("/rpc/Cover.GetStatus?id=" + ID);
IF response.IsSuccess
    Cover.GetStatus := response.Content;  
END

response := SENDHTTPREQUEST("/rpc/Cover.GetConfig?id=" + ID);
IF response.IsSuccess
    Cover.GetConfig := response.Content;
END

if ! parsejson(Cover.GetStatus, "$.pos_control", true)
    #adderror("${presence_calibration_required}");
    adderror("Calibration is required");
end

if ! ISNULL(parsejson(Cover.GetStatus, "errors", true))
    adderror("Error: " + parsejson(Cover.GetStatus, "errors"));
end
```

Čitanje položaja žaluzine

```taphome
var pos := PARSEJSON(Cover.GetStatus, "$.current_pos", true);
if ! isnull(PARSEJSON(Cover.GetStatus, "$.target_pos", true))
	pos := PARSEJSON(Cover.GetStatus, "$.target_pos", true);
end

return(linear(pos,0,1,100,0));
```

Zapis položaja žaluzine

```taphome
VAR response := SENDHTTPREQUEST("rpc/Cover.GoToPosition?id=" + ID + "&pos=" + round(linear(Bl,0,100,1,0)));
IF response.IsSuccess = false
  ADDERROR(response.StatusCode);
END

response := SENDHTTPREQUEST("/rpc/Cover.GetStatus?id=" + ID);
IF response.IsSuccess
    Cover.GetStatus := response.Content;  
END
```

Servisni atributi

${device\_variable\_realtemperature} \[°C]

```taphome
parsejson(Cover.GetStatus, "$.temperature.tC", true)
```

${device\_variable\_electricityconsumption} \[Wh]

```taphome
parsejson(Cover.GetStatus, "$.aenergy.total", true)
```

${device\_variable\_electricitydemand} \[W]

```taphome
parsejson(Cover.GetStatus, "$.apower", true)
```

${valueLogType\_ElectricVoltage} \[V]

```taphome
parsejson(Cover.GetStatus, "$.voltage", true)
```

${valueLogType\_ElectricCurrent} \[A]

```taphome
parsejson(Cover.GetStatus, "$.current", true)
```

Servisne radnje

${start\_automatic\_calibration}

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Cover.Calibrate?id=" + ID);
IF response.IsSuccess
    return("OK");
else
    return("Error");
END
```

Žaluzina Žaluzina Čitanje i pisanje

Vanjska žaluzina s upravljanjem položajem i nagibom lamela — zahtijeva profil cover, kalibraciju i uključeno upravljanje lamelama

numeric Jedinica: %

Servisni atributi

|                           |                                                                         |
|---------------------------|-------------------------------------------------------------------------|
| Temperatura               |                                                                         |
| Potrošnja energije        |                                                                         |
| Trenutačna snaga          |                                                                         |
| Električni napon          |                                                                         |
| Električna struja         |                                                                         |
| Lamele                    | Je li upravljanje nagibom lamela uključeno u konfiguraciji Shelly Cover |
| Vrijeme otvaranja lamela  |                                                                         |
| Vrijeme zatvaranja lamela |                                                                         |

Servisne radnje

|                                |                                                                                                   |
|--------------------------------|---------------------------------------------------------------------------------------------------|
| Pokreni automatsku kalibraciju |                                                                                                   |
| Postavi lamele                 | Uključuje upravljanje lamelama i postavlja trajanje otvaranja i zatvaranja lamela (0,1–5 sekundi) |

Čitanje (modul)

```taphome
if PARSEJSON(Sys.GetConfig, "$.device.profile") != "cover"
	adderror("Profile is not set to cover (" + PARSEJSON(Sys.GetConfig, "$.device.profile") + ")");
end

VAR response := SENDHTTPREQUEST("/rpc/Cover.GetStatus?id=" + ID);
IF response.IsSuccess
    Cover.GetStatus := response.Content;  
END

response := SENDHTTPREQUEST("/rpc/Cover.GetConfig?id=" + ID);
IF response.IsSuccess
    Cover.GetConfig := response.Content;
END

if ! parsejson(Cover.GetStatus, "$.pos_control", true)
    #adderror("${presence_calibration_required}");
    adderror("Calibration is required");
end

if ! ISNULL(parsejson(Cover.GetStatus, "errors", true))
    adderror("Error: " + parsejson(Cover.GetStatus, "errors"));
end
```

Čitanje položaja žaluzine

```taphome
var pos := PARSEJSON(Cover.GetStatus, "$.current_pos", true);
var target := PARSEJSON(Cover.GetStatus, "$.target_pos", true);
var slatPos := PARSEJSON(Cover.GetStatus, "$.slat_pos", true);

BlSend := 0;
if BsSend = 0 and (Bs = 0 or Bs = 1) 
	if (!isnull(target))
		DeltaPos := 0;
		return(linear(target,0,1,100,0));
	else
		return(linear(pos - DeltaPos,0,1,100,0));	
	end
end

return(Bl);
```

Zapis položaja žaluzine

```taphome
var pos := PARSEJSON(Cover.GetStatus, "$.current_pos", true);
var target := PARSEJSON(Cover.GetStatus, "$.target_pos", true);
var slatPos := PARSEJSON(Cover.GetStatus, "$.slat_pos", true);

VAR response := SENDHTTPREQUEST("rpc/Cover.GoToPosition?id=0&pos=" + round(linear(Bl,0,100,1,0)));
BlSend := 1;
IF response.IsSuccess = false
  ADDERROR(response.StatusCode);
END

#response := SENDHTTPREQUEST("/rpc/Cover.GetStatus?id=0");
#IF response.IsSuccess
#    Cover.GetStatus := response.Content;  
#END
```

Čitanje kuta lamela

```taphome
var pos := PARSEJSON(Cover.GetStatus, "$.current_pos", true);
var slatPos := PARSEJSON(Cover.GetStatus, "$.slat_pos", true);
var state := PARSEJSON(Cover.GetStatus, "$.state", true);
var date := NOW();

if ISNULL(slatPos)
    adderror("Slat position must be enabled for blinds");
    return(NaN);
end

if state = "closing" or state = "opening"
	BsSend := 1;
	return(Bs);
end

if BsSend > 1
	BsSend := 1;
	return(Bs);
else
	if BsSend = 1
		BsSend := 0;
		DeltaPos := pos - round(linear(Bl,0,100,1,0));	
	end
	return(linear(slatPos,0,1,100,0));
end
```

Zapis kuta lamela

```taphome
var date := NOW();
var pos := PARSEJSON(Cover.GetStatus, "$.current_pos", true);

if BlSend = 0
	VAR response := SENDHTTPREQUEST("rpc/Cover.GoToPosition?id=0&pos=" + pos + "&slat_pos=" + round(linear(Bs,0,100,1,0)));
	BsSend := date.UNIXTIME;
	IF response.IsSuccess = false
	  ADDERROR(response.StatusCode);
	END
end

#response := SENDHTTPREQUEST("/rpc/Cover.GetStatus?id=0");
#IF response.IsSuccess
#    Cover.GetStatus := response.Content;  
#END
```

Servisni atributi

${device\_variable\_realtemperature} \[°C]

```taphome
parsejson(Cover.GetStatus, "$.temperature.tC", true)
```

${device\_variable\_electricityconsumption} \[Wh]

```taphome
parsejson(Cover.GetStatus, "$.aenergy.total", true)
```

${device\_variable\_electricitydemand} \[W]

```taphome
parsejson(Cover.GetStatus, "$.apower", true)
```

${valueLogType\_ElectricVoltage} \[V]

```taphome
parsejson(Cover.GetStatus, "$.voltage", true)
```

${valueLogType\_ElectricCurrent} \[A]

```taphome
parsejson(Cover.GetStatus, "$.current", true)
```

Slat

```taphome
if(parsejson(Cover.GetConfig, "$.slat.enable", true), "Enabled", "Disabled")
```

Slat open time \[s]

```taphome
parsejson(Cover.GetConfig, "$.slat.open_time ", true)
```

Slat close time \[s]

```taphome
parsejson(Cover.GetConfig, "$.slat.open_time ", true)
```

Servisne radnje

${start\_automatic\_calibration}

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Cover.Calibrate?id=" + ID);
IF response.IsSuccess
    return("OK");
else
    return("Error");
END
```

Set Slat

Parametri: Open time \[s] (0.1–5 ot), Close time \[s] (0.1–5 ct)

```taphome
VAR response := SENDHTTPREQUEST("/rpc/Cover.SetConfig?id=" + ID + 
	"&config={\"slat\":{\"enable\":true, \"open_time\": " + ot +", \"close_time\": " + ct +"}}");
IF response.IsSuccess
    return("OK");
else
    return("Error");
END
```

**Povezivanje:** Packet Parser → HTTP • Naziv računala (hostname): `shelly2pmg3-{MAC}.local`

Moguća poboljšanja (11)

- Input 1 State — Physical switch/button input 1 state, available via /rpc/Input.GetStatus?id=0
- Input 2 State — Physical switch/button input 2 state, available via /rpc/Input.GetStatus?id=1
- Returned Energy — Returned/exported energy in Wh, for bi-directional metering scenarios
- Uptime — Seconds since last reboot, available in Sys.GetStatus response
- RAM Usage — Total and free RAM in bytes, available in Sys.GetStatus response
- Device Time — Current device time in HH:MM format, available in Sys.GetStatus response
- Auto-off Timer — Auto-reset timer in seconds via toggle\_after parameter, could be added as switch parameter
- Reset Energy Counters — Resets energy measurement counters (aenergy, ret\_aenergy) for both channels
- Overpower Protection — Configurable power limit threshold in Watts, relay turns off when exceeded
- Cover State — Cover movement state (open/opening/closed/closing/stopped/calibrating), available in Cover.GetStatus
- Cover Open/Close/Stop Commands — Direct open/close/stop commands without position parameter; template uses GoToPosition instead

## Parametri uvoza

Ove vrijednosti unosite pri uvozu XML-a.

| Pitanje u aplikaciji | Zadano        |
|----------------------|---------------|
| IP adresa            | `192.168.0.1` |

## Izvori

- Shelly Gen2+/Gen3 RPC API Reference
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen2/) 2026-03-27
- Shelly Gen2+ Switch Component API
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/Switch/) 2026-03-27
- Shelly Gen2+ System (Sys) Component API
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/Sys/) 2026-03-27
- Shelly Gen2+ WiFi Component API
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/WiFi/) 2026-03-27
- Home Assistant Shelly Integration
  
  [www.home-assistant.io](https://www.home-assistant.io/integrations/shelly/) 2026-03-27
- Shelly 2PM Gen3 Knowledge Base
  
  [kb.shelly.cloud](https://kb.shelly.cloud/knowledge-base/shelly-2pm-gen3) 2026-03-29

## Povezana dokumentacija

- [Packet Parser Integration](https://taphome.com/hr/compatibility/packet-parser-guide/)
- [Packet Parser (HTTP, TCP, UDP, FTP, MQTT)](https://taphome.com/hr/docs/integration/packet-parser/)
- [Funkcije Packet parsera](https://taphome.com/hr/docs/script/packet-parser/)
- [Funkcije za raščlambu](https://taphome.com/hr/docs/script/parsing-functions/)