title: "Schrack i-CHARGE CION"
description: "Punionica Schrack Technik i-CHARGE CION (11 kW i 22 kW) integrirana preko Modbus RTU na RS-485."
url: "https://taphome.com/hr/compatibility/schrack-i-charge-cion/"
language: hr
lastmod: 2026-03-28
generator: hugo
ai:
  topics: ["modbus-rtu","wallbox","rs485","ev-charger","dip-switch","mode-3"]
  questions: ["Kako integrirati Schrack i-CHARGE CION sa sustavom TapHome?","Čime upravlja predložak TapHome za Schrack i-CHARGE CION?","Kako spojiti Schrack i-CHARGE CION preko RS-485 na TapHome?","Kako uključiti način Modbus RTU na punionici Schrack i-CHARGE CION?","Koje su postavke DIP sklopki potrebne za Modbus na punionici i-CHARGE CION?","Kako preko sustava TapHome upravljati strujom punjenja električnog vozila?"]
---

# Schrack i-CHARGE CION

Komunikacija: Modbus RTU

- [Službena stranica Schrack Technik](https://www.schrack.com)

## Upute za integraciju

Schrack Technik i-CHARGE CION je punionica za električna vozila koja radi u načinu Mode 3, dostupna u izvedbama od 11 kW i 22 kW. Sa sustavom TapHome komunicira protokolom Modbus RTU preko RS-485. Budući da centralna jedinica TapHome Core koristi Modbus TCP, između sustava TapHome i punionice potreban je pristupnik (gateway) Modbus TCP na RS-485 (npr. pretvornik Waveshare RS485-to-Ethernet).

Predložak TapHome omogućuje upravljanje punjenjem (odobravanje i zabrana, zadana struja, najmanja struja), praćenje stanja signala CP, prepoznavanje kabela, upravljanje zaključavanjem utičnice, očitanje napona i temperature te dijagnostička upozorenja za česte kvarove.

## Hardversko spajanje

### Ožičenje RS-485 Modbus RTU

![Shema upravljača punjenja Schrack i-CHARGE CION — spoj RS-485 Modbus RTU](https://taphome.com/images/compatibility/schrack-i-charge-cion/wiring-rs485-modbus_hu_db6f283de3df0e90.jpg)

Sabirnica RS-485 spaja se na stezaljke **A** i **B** upravljača punjenja na donjem dijelu pločice. Spojite ih na Modbus TCP pristupnik:

- **A** → A+/D+ na pristupniku RS-485
- **B** → B-/D- na pristupniku RS-485

Koristite standardni CAT kabel (CAT5 ili bolji). Prema proizvođaču, uzemljenje oklopa za prijenos podataka **nije potrebno**.

> [!NOTE]
> DIP sklopke 1 i 2 moraju obje biti u položaju **OFF** da bi stezaljke RS-485 postale aktivne. U načinu Modbus RTU vanjski ulazi E1 i E3 se zanemaruju.

### Pregled pločice upravljača

![Pločica upravljača punjenja Schrack i-CHARGE CION — raspored stezaljki s priključcima RS-485, E1, E3 i RFID](https://taphome.com/images/compatibility/schrack-i-charge-cion/wiring-controller-schematic_hu_eb444934f60a2009.jpg)

Pločica upravljača ima sljedeće stezaljke (gornji red, slijeva nadesno): A4, A3, A2, A1, E1, E3, Pb, Pa. Linije RS-485 A/B spajaju se na donjem dijelu pločice. RFID čitač spaja se preko priključka RJ11.

## Konfiguracija

### Uključivanje Modbus komunikacije

![Postavke DIP sklopki punionice Schrack i-CHARGE CION — položaji 1–4](https://taphome.com/images/compatibility/schrack-i-charge-cion/dip-switch-configuration_hu_3c2be14791878f3.jpg)

DIP sklopka s 4 položaja na upravljaču punjenja određuje način rada i najveću struju punjenja.

**DIP sklopke 1–2 — način rada:**

| DIP 1 | DIP 2 | Način rada |
|-------|-------|------|
| **OFF** | **OFF** | **RS-485 Modbus RTU** (potrebno za TapHome) |
| OFF | ON | Normalan rad, sučelje 0–10 V, način 1 |
| ON | OFF | Normalan rad, sučelje 0–10 V, način 2 |
| ON | ON | Brisanje i učenje RFID kartica |

**DIP sklopke 3–4 — najveća struja punjenja:**

| DIP 3 | DIP 4 | Struja |
|-------|-------|---------|
| ON | ON | 32 A (samo modeli od 22 kW) |
| OFF | ON | 20 A (samo modeli od 22 kW) |
| ON | OFF | 16 A |
| OFF | OFF | 13 A (zadano) |

> [!WARNING]
> Nakon promjene položaja DIP sklopki punionicu treba ponovno pokrenuti kako bi nove postavke počele vrijediti.

### Komunikacijski parametri

| Parametar | Zadana vrijednost |
|-----------|---------------|
| Brzina prijenosa (baud rate) | 57600 |
| Podatkovni bitovi | 8 |
| Stop bitovi | 1 |
| Paritet | nema |
| Slave ID | 1 |

Slave ID se može promijeniti preko Modbus registra H:500. Brzina prijenosa može se promijeniti preko registra H:509 (0=9600, 1=14400, 2=19200, 3=28800, 4=38400, 5=57600; ostale vrijednosti znače 115200).

## Mogućnosti uređaja

### Upravljanje punjenjem

- **Odobrenje punjenja** (H:100) — omogućuje ili onemogućuje punjenje. U načinu Modbus ima prednost pred vanjskim ulazom E1. Uređaj javlja i **Trajanje punjenja** kao servisni atribut, koji prikazuje proteklo vrijeme punjenja u formatu HH:MM:SS.
- **Zadana struja punjenja** (H:101) — postavlja aktivnu struju punjenja u amperima, ograničenu na 6–32 A.
- **Najmanja struja punjenja** (H:507) — postavlja prag najmanje struje punjenja u amperima (zadano 13 A, raspon 6–32 A). Uglavnom se koristi kao donja granica za sučelje 0–10 V za solarnu elektranu.

### Praćenje stanja

- **Stanje CP** (H:139) — prikazuje stanje upravljačkog signala (control pilot) za Mode 3: A (pripravnost), B (vozilo prepoznato), C (spremno/punjenje), D (s ventilacijom), E (nema napajanja), F (greška) ili U (nepoznato).
- **Kabel za punjenje priključen** (H:121, bit 0) — binarni senzor koji pokazuje je li kabel za punjenje priključen. Uređaj javlja i **Trajanje priključenosti** kao servisni atribut.
- **Trenutačna struja punjenja** (H:126) — senzor samo za čitanje koji prikazuje trenutačnu struju punjenja u amperima.

### Napon i temperatura

- **Napon faze 1** (H:167) — mrežni napon na fazi 1; neobrađena vrijednost dijeli se sa 100 za prikaz u voltima.
- **Temperatura** (H:303) — ugrađeni senzor temperature u upravljaču punjenja, vrijednost u °C.

### Zaključavanje utičnice

- **Zaključavanje utičnice** (H:118) — upravlja zaključavanjem utičnice za punjenje u tri načina: Automatski (zadano), Zaključaj ili Otključaj.

### Dijagnostika

ReadScript na razini modula stalno prati stanja grešaka i javlja upozorenja u sustavu TapHome:

| Uvjet | Upozorenje |
|-----------|---------|
| H:306 != 0 | Greška upravljača |
| H:146 != 0 | Greška vjerodostojnosti signala PP/CP |
| H:121 bit 6 | Skupna greška |
| H:121 bit 7 | Nestanak napajanja (RCCB/MCB) |
| H:121 bit 8 | Neispravan kabel za punjenje |
| H:121 bit 9 | Kabel za punjenje odbijen |
| H:121 bit 10 | Greška sklopnika za punjenje |
| H:121 bit 12 | Neuspješan samotest RCMU |
| H:121 bit 13 | Otkrivena diferencijalna struja |

### Dodatne mogućnosti

i-CHARGE CION daje i registre za upravljanje LED-ovima (ručno uključivanje LED-ova Ready/Charging i RGB signalizacija), povratno očitanje najveće struje punjenja, strujnu opteretivost kabela, stanje generatora CP, prepoznavanje kabela preko PP, riječ greške s pojedinačnim bitovima kvarova, praćenje napona napajanja, očitanje ulaznih napona (E1, E3), prepoznavanje grešaka konfiguracije, vremenske načine zaključavanja utičnice, analogni senzor temperature, faktor skaliranja za solarnu elektranu i preklapanje faza preko izlaza A4 (za upravljanje vanjskim sklopnikom). Mogu se dodati u budućem ažuriranju predloška.

## Rješavanje problema

### Nema Modbus komunikacije

1. Provjerite jesu li DIP sklopke 1 i 2 obje u položaju **OFF**
2. Provjerite ožičenje RS-485: A na A+, B na B-
3. Provjerite je li Modbus TCP pristupnik postavljen na 57600 baud, 8N1
4. Provjerite odgovara li slave ID (zadano: 1, može se promijeniti preko H:500)
5. Nakon svake promjene DIP sklopki ponovno pokrenite punionicu

### Odobrenje punjenja nema učinka

Zastavica „Charging authorisation ignored” (H:120) postavlja se kada se odobrenje punjenja ne može primijeniti, na primjer kada vozilo nije priključeno, postoji greška kabela ili je punionica u stanju greške. Najprije uklonite uzrok.

### Očitani napon izgleda pogrešno

Napon faze 1 (H:167) koristi množitelj 1/100: neobrađena vrijednost 23000 odgovara 230,00 V. Ako se prikazana vrijednost čini 100 puta prevelikom, provjerite je li uređaj u sustavu TapHome postavljen s ispravnom pretvorbom.

## Dostupni uređaji 9

Ovi se uređaji pojavljuju u TapHomeu nakon uvoza.

Schrack i-CHARGE CION Modul

Servisni atributi

|                   |                                                                                                                   |
|-------------------|-------------------------------------------------------------------------------------------------------------------|
| Naziv proizvođača |                                                                                                                   |
| Naziv uređaja     |                                                                                                                   |
| Verzija firmvera  |                                                                                                                   |
| Brzina prijenosa  | Trenutačna brzina prijenosa za Modbus — dekodirana vrijednost: 9600, 14400, 19200, 28800, 38400, 57600 ili 115200 |
| RFID oznaka       | Identifikator posljednje očitane RFID oznake                                                                      |

Servisne radnje

|                               |                                                 |
|-------------------------------|-------------------------------------------------|
| Ponovno pokretanje upravljača | Potpuno ponovno pokreće upravljač punjenja EVCC |

Čitanje (modul)

```taphome
if(modbusr(H, 306, Uint16), ADDWARNING("Storung"));
if(modbusr(H, 146, Uint16), ADDWARNING("Plausibitatzfehler bei PPbzw. CP"));
var r121 := modbusr(H, 121, Uint16);
if(getbit(r121, 6), ADDWARNING("Sammelstorung"));
if(getbit(r121, 7), ADDWARNING("Storung: Netzausfall FI/LS"));
if(getbit(r121, 8), ADDWARNING("Storung: Ladekabel"));
if(getbit(r121, 9), ADDWARNING("Storung: Ladekabel abgewiesen"));
if(getbit(r121, 10), ADDWARNING("Storung: charging contactor"));
if(getbit(r121, 12), ADDWARNING("Storung: RCMU Selbttest fehler"));
if(getbit(r121, 13), ADDWARNING("Storung: Fehlerstrom"));
```

Servisni atributi

Herstellerbezeichnung

```taphome
modbusr(H, 800, String, 15)
```

Geratebezeichnung

```taphome
modbusr(H, 816, String, 15)
```

Firmwareversion

```taphome
modbusr(H, 832, String, 16)
```

Baudrate

```taphome
switch(modbusr(H, 509, Uint16),
0, 9600,
1, 14400,
2, 19200,
3, 28800,
4, 38400,
5, 57600,
115200)
```

RFID Tag

```taphome
modbusr(H, 129, String, 4)
```

Servisne radnje

Controller Neustart

```taphome
modbusw(H, 1000, Uint16, 1234)
```

Trenutačna struja punjenja Varijabla Samo za čitanje

Trenutačna struja punjenja u načinu Mode 3, u amperima

Registar: H:126 UInt16 Jedinica: A numeric

Čitanje

```taphome
MODBUSR(H, 126, Uint16)
```

Odobrenje punjenja Sklopka Čitanje i pisanje

Omogućuje ili onemogućuje punjenje električnog vozila — u načinu Modbus ima prednost pred vanjskim ulazom E1

Registar: H:100 UInt16

Vrijednosti / stanja: ${general\_enabled} · ${general\_disabled}

Čitanje stanja sklopke

```taphome
MODBUSR(H, 100, Uint16)
```

Zapis stanja sklopke

```taphome
MODBUSW(H, 100, Uint16, St)
```

Servisni atributi

Ladedauer

```taphome
var total := MODBUSR(H, 151, LittleEndianUint32);
var sec := mod(total, 60);
var min := mod(floor(total/60), 60);
var hod := floor(total/3600);

hod + ":" + tostring(min, "X2") + ":" + tostring(sec, "X2")
```

Stanje CP Prekidač s više vrijednosti Samo za čitanje

Stanje upravljačkog signala (control pilot) Mode 3 — A (pripravnost), B (vozilo prepoznato), C (spremno/punjenje), D (s ventilacijom), E (nema napajanja), F (greška), U (nepoznato)

Registar: H:139 Char numeric

Vrijednosti / stanja: A - Standby · B - Vehicle detected · C - Ready (charging) · D - With ventilation · E - No power (shut off) · F - Error · U - Unknown

Čitanje stanja sklopke

```taphome
switch(MODBUSR(H, 139, Uint16),
65, 0,
66, 1,
67, 2,
68, 3,
69, 4,
70, 5,
6)
```

Kabel za punjenje priključen Magnetski kontakt Samo za čitanje

Registar: H:121 UInt16 bitmask

Servisni atributi

|                         |                                                   |
|-------------------------|---------------------------------------------------|
| Trajanje priključenosti | Trajanje priključenosti kabela u formatu HH:MM:SS |

Čitanje

```taphome
GETBIT(MODBUSR(H, 121, Uint16), 0)
```

Servisni atributi

Angesteckt-Dauer

```taphome
var total := MODBUSR(H, 153, LittleEndianUint32);
var sec := mod(total, 60);
var min := mod(floor(total/60), 60);
var hod := floor(total/3600);

hod + ":" + tostring(min, "X2") + ":" + tostring(sec, "X2")
```

Zadana struja punjenja Varijabla Čitanje i pisanje

Aktivna postavka struje punjenja u amperima, podesiva od 6 do 32 A

Registar: H:101 UInt16 Jedinica: A numeric

Čitanje

```taphome
MODBUSR(H, 101, Uint16)
```

Zapis

```taphome
MODBUSW(H, 101, Uint16, LINEAR(Va, 6, 6, 32, 32, BOUNDS))
```

Najmanja struja punjenja Varijabla Čitanje i pisanje

Prag najmanje struje punjenja u amperima (zadano 13 A) — donja granica za sučelje 0–10 V za solarnu elektranu

Registar: H:507 UInt16 Jedinica: A numeric

Čitanje

```taphome
MODBUSR(H, 507, Uint16)
```

Zapis

```taphome
MODBUSW(H, 507, Uint16, LINEAR(Va, 6, 6, 32, 32, BOUNDS))
```

Napon faze 1 Varijabla Samo za čitanje

Registar: H:167 UInt16 Jedinica: V numeric

Čitanje

```taphome
MODBUSR(H, 167, Uint16)
```

Temperatura Senzor temperature Samo za čitanje

Registar: H:303 UInt16 Jedinica: °C numeric

Čitanje temperature

```taphome
MODBUSR(H, 303, Uint16)
```

Zaključavanje utičnice Prekidač s više vrijednosti Čitanje i pisanje

Upravljanje zaključavanjem utičnice za punjenje — Automatski, Zaključaj ili Otključaj

Registar: H:118 UInt16 numeric

Vrijednosti / stanja: Automatic · Verriegeln · Entriegeln

Čitanje stanja sklopke

```taphome
switch(MODBUSR(H, 118, Uint16),
1, 1,
2, 2,
0)
```

Zapis stanja sklopke

```taphome
MODBUSW(H, 118, Uint16, Mu)
```

**Povezivanje:** Modbus RTU • 57600 baud• 8N1 • Slave ID: $\[SlaveId]

Moguća poboljšanja (25)

- H:102 Automatic LED Activation — 0=manual LED control via registers 103-117, 1=automatic. Low priority — cosmetic
- H:103-117 LED Control Registers — Manual control of Ready/Charging LEDs and RGB signalling. 15 registers for timing, duty, color. Low priority — cosmetic
- H:120 Charging Authorisation Ignored — Read-only flag indicating charging authorisation was ignored (e.g. no car connected, error). Useful for diagnostics
- H:121 bits 1-5 Additional Status Bits — Contactor 1/2 active, ventilation requested, connector locking activation/response. Template only uses bit 0 (cable plugged) and bits 6-13 (errors in readscript)
- H:127 Maximum Charging Current — Maximum Mode 3 charging current value in A. Read-only. Useful to show hardware limit
- H:128 Cable Current Carrying Capacity — Current carrying capacity of charging cable in A: 0, 13, 20, 32, 63. Read-only
- H:140 CP Generator State — 0=high resistance, 1=DC positive, 2=DC negative, 3=PWM. Low-level diagnostics
- H:141 PP Status — Proximity pilot cable identification: 0, 13, 20, 32, 63 A, or SC. Read-only. Partially covered by operating manual reference
- H:147 Configuration Error — 0=no error, 1=plausibility error in configuration. Read-only diagnostic
- H:148 Voltage E1 — Voltage at input E1 in mV (multiplier 1/1000). DC input for external activation
- H:149 Voltage E3 — Voltage at input E3 in mV (multiplier 1/1000). DC input for 0-10V PV interface
- H:150 Error Word — 16-bit error word with 9 individual error bits. Partially covered by readscript warnings on H:121 bits 6-13
- H:300 Operating Mode — 0=slave. Read-only. Low value — always 0 in Modbus RTU mode
- H:301 Supply Voltage — Supply voltage of charging controller in mV (multiplier 1/1000). Internal diagnostics
- H:302 Mains Voltage — Mains voltage measured at RCCB/MCB in V (multiplier 1/100). Alternative to H:167
- H:305 Locked Time Mode — Connector lock timing mode: 1=plugged-to-unplugged, 2=charging-start-to-end, 3=charging-start-to-unplugged. R/W
- H:307 Analogue Temperature Sensor — Temperature measured value in mV. Raw analogue reading, lower priority than H:303
- H:308 A4 Control via Modbus — Control signal output A4 for external contactor. Used for phase switching (L2/L3) with safety constraints. R/W
- H:500 Bus Address Override — Modbus slave address override. Default 1. R/W
- H:501 Default Charging Current Override — Default charging current in A, only effective with specific DIP switch position. R/W
- H:503 Locking Delay — Connector locking delay in ms. Default 250ms. R/W
- H:505 Motor Activation Time — Lock motor activation time in ms. Default 500ms. R/W
- H:506 Cable Mode — 0=charging socket, 1=permanently connected cable. R/W
- H:508 PV Scaling — x ampere per volt for PV control via 0-10V interface. Default 6 A/V. R/W
- H:700 DIP Switch Configuration — Read DIP switch state via Modbus. Not in official register table — undocumented register found in nymea plugin

## Parametri uvoza

Ove vrijednosti unosite pri uvozu XML-a.

| Pitanje u aplikaciji | Zadano        |
|----------------------|---------------|
| Slave Id             | `1`           |
| IP address           | `192.168.1.0` |

## Izvori

- Modbus Register Table CION Home and Semipublic (EN)
  
  [image.schrack.com](https://image.schrack.com/dokumentationen/cion_doku/emcion11cr/modbusregistertabelle/a_emcion_homecontroller_modbus_lookup_table_en.pdf) 2026-03-28
  
  [PDF](https://taphome.com/compatibility/devices/schrack-i-charge-cion/manufacturer/modbus-register-table-en.pdf)
- Operating Manual i-CHARGE CION V2.2 (EN)
  
  [image.schrackcdn.com](https://image.schrackcdn.com/bedienungsanleitungen/a_emcionxxxx_evcchome_v2.2_en.pdf) 2026-03-28
  
  [PDF](https://taphome.com/compatibility/devices/schrack-i-charge-cion/manufacturer/operating-manual-en.pdf)
- Nymea Modbus Plugin — CION Register Definitions
  
  [github.com](https://github.com/nymea/nymea-plugins-modbus/blob/master/schrack/cion-registers.json) 2026-03-28
- evcc Discussion — CION Phase Switching
  
  [github.com](https://github.com/evcc-io/evcc/discussions/11059) 2026-03-28

Dokumenti proizvođača zaštićeni su autorskim pravom (©) svojih vlasnika. Dostupni su onako kako ih je proizvođač objavio, samo za informaciju.

## Povezana dokumentacija

- [Modbus Integration](https://taphome.com/hr/compatibility/modbus-guide/)
- [Modbus](https://taphome.com/hr/docs/integration/modbus/)
- [Jednostavna konfiguracija pomoću predložaka](https://taphome.com/hr/docs/integration/modbus/templates/)
- [Skripte Modbus i prefetch](https://taphome.com/hr/docs/script/modbus-scripts/)
- [Funkcije Modbus](https://taphome.com/hr/docs/script/modbus/)
- [Tipovi podataka Modbus](https://taphome.com/hr/docs/script/modbus-data-types/)