Bridging comb for relay modules: one insulated part instead of jumper wires
On the 12 DO, 16 DO and 12 DO 12 UI modules, outputs that share a phase are bridged today with short jumper wires. An insulated bridging comb would connect the common terminals in one step and keep the wiring clear.
Why and how you would use it
The relay outputs of the 12 DO, 16 DO and 12 DO 12 UI modules are potential-free. Each output has two screw terminals: one for the supply and one for the load. When several outputs switch the same phase, the installation guide asks you to bring the phase to the first output and then make short jumper wires from each common terminal to the common terminal of the next output.
An example from practice: a 16 DO module that switches lights on one phase needs fifteen short jumpers, each cut, stripped and tightened at both ends, before the first load wire goes in. It takes time, the jumpers crowd the terminals and the board is harder to check later.
| Today | With this idea |
|---|---|
| Short jumper wires | One insulated comb |
| Cut and strip each | Push in and tighten |
| Crowded terminals | Clear wiring |
What will be possible
We are evaluating this idea. Nothing is scheduled yet.
- An insulated bridging comb. It would connect the common terminals of the relay outputs, every second terminal, and leave the other terminals free for the load wires.
- One part for each terminal pitch. The 12 DO and 16 DO have relay terminals 6.35 mm apart and the 12 DO 12 UI 5.08 mm apart, so each would get its own comb.
- Groups on different phases. A comb cut to length would bridge only the outputs that share one phase.
What will not be possible
- More current than the module allows. The comb would carry the current of the whole group, so the feed wire and the circuit breaker stay sized by the module limits.
- Bridging the neutral. The neutral of each load still goes straight to the neutral busbar, not through the module.
- Other modules in a first version. Input modules and modules without relay outputs are not part of it.
How to solve it today
Bring the phase to the first output and connect the common terminals with short jumper wires, as the installation guide of each module describes. Check the wire sizes the terminals accept on the product page:
Learn more
Would a ready-made comb save you time in the distribution board? Vote for this idea and follow it for updates.
Related
Status history
- Nov 23, 2026 Gathering interest Published
Comments 0
Sign in with your TapHome account to comment. The team approves comments before they appear.
No comments yet.
·
The original comment was deleted.
Ideas describe direction, not commitments. We do not publish dates; released features are announced in the release notes.
Sign in with your TapHome account to follow. We email you when something changes; unsubscribe in one click.
Want to know when this moves forward?
Follow this idea to get an email when its status changes. Unsubscribe in one click.
Sign in with your TapHome account to follow. We email you when something changes; unsubscribe in one click.
Confirming your vote…