# EEBUS support: power limit, power monitoring and PV surplus for heat pumps and wallboxes

TapHome as a local EEBUS energy manager: cap and read the power of heat pumps and EV chargers and hand PV surplus to the heat pump, across brands, without a template per model. EEBUS cannot set the flow water temperature or control cooling on any heat pump; those stay with the Modbus and eBUS templates.

- Status: Gathering interest — We collect use cases and votes before we decide.
- Type: Integration
- 1 interested
- Topics: [Energy](https://taphome.com/en/ideas/topics/energy/), [Integrations and protocols](https://taphome.com/en/ideas/topics/integrations-protocols/)
- Last updated: 2026-11-23


## Why and how you would use it

Heat pumps and EV chargers are the biggest loads in a modern house. To keep them under the main breaker and run them on solar surplus, TapHome today needs a separate template for each brand, or a relay on the SG Ready contacts of the heat pump.

EEBUS is an open, manufacturer-independent standard for energy devices on the home network. It runs locally on the LAN: when two devices pair, each confirms the other's key once, and then they exchange data in standardised functions called use cases. In Germany it is the recognised interface for grid-operator power limiting of heat pumps and wallboxes (§ 14a EnWG), so more and more of them ship with it.

Example: an installer fits a Vaillant heat pump with a VR 940f internet module and asks whether TapHome can use its EEBUS interface. Today it cannot. With this idea TapHome could cap the heat pump's power while the car charges, and start an extra hot water run when the panels produce more than the house uses. It still could not set the flow water temperature, because EEBUS has no such function.

| | Today | With this idea |
|---|---|---|
| Power limit | Template per brand | One EEBUS link |
| Power reading | Extra meter | From the device |
| PV surplus run | SG Ready relay | Heat pump offers it |

## What will be possible

TapHome would act as a local EEBUS energy manager for heat pumps and wallboxes of several brands:

- **Power limit.** TapHome sends a watt limit to the heat pump or wallbox, for example to stay under the main breaker while other loads run.
- **Power reading.** The device reports its own consumption without an extra meter. Some brands report a calculated value, not a measured one.
- **PV surplus to the heat pump.** The heat pump offers an optional run, for example heating the hot water tank above its setpoint, and TapHome starts, pauses or stops it when there is surplus.
- **EV charging.** Current limit and metering for EEBUS wallboxes such as Elli, Volkswagen, Škoda, Cupra, Porsche and WARP.
- **Energy Manager.** EEBUS devices would work as loads in the Energy Manager smart rule, next to relays and analog outputs.
- **Vaillant only.** Room setpoint and mode per heating zone of the VRC 720 controller (up to 3 zones), hot water setpoint, mode and one-time boost, outdoor temperature.

## What will not be possible

- **No flow water temperature.** The EEBUS standard has no function for the flow (supply) water temperature of a heating circuit, and no manufacturer offers one over EEBUS.
- **No cooling.** Cooling cannot be controlled over EEBUS on any heat pump we checked.
- **One energy manager per device.** A device usually accepts one EEBUS energy manager at a time. If a Sunny Home Manager, a SolarEdge controller or a grid operator control box is already paired, TapHome competes with it.
- **Pairing in the manufacturer's app.** Pairing often has to be confirmed in the manufacturer's app, which for some brands needs its cloud. Normal operation is local.
- **Firmware decides.** The functions depend on the firmware of the heat pump or gateway, and some manufacturers change data points with updates.

## How to solve it today

TapHome controls heat pumps and wallboxes through each brand's own local interface:

- **Energy Manager.** The [Energy Manager](https://taphome.com/en/docs/energy-manager/) smart rule switches heat pumps and regulates wallboxes by solar surplus and priority, and keeps grid import under a limit, with a meter on the main supply.
- **SG Ready.** A TapHome relay switches the SG Ready or heat demand input of the heat pump, if it has one ([Hydronic heating and cooling](https://taphome.com/en/docs/setup/requirements/#water-heating)).
- **Heat pump templates.** NIBE (SMO S40, VVM S320, F1245), Stiebel Eltron HPA-O through ISG, Daikin Altherma 3 through DCOM-LT/MB, Mitsubishi Ecodan through Procon MelcoBEMS MINI, Viessmann Vitocal through Vitogate 300, Bosch, Buderus and IVT through EMS-ESP, and Vaillant through an eBUS adapter with micro-ebusd. Several of these interfaces also offer flow or cooling setpoints, which EEBUS does not have, and the templates could be extended with them.
- **Wallboxes.** Templates for KEBA KeContact P20 and P30 and go-e Gemini flex. All templates are in the [compatibility list](https://taphome.com/en/compatibility/).

## Heat pumps and EEBUS by brand

What each manufacturer offers over EEBUS, from its documentation and from integrators. No brand offers the flow water temperature or cooling over EEBUS.

| Brand | EEBUS through | Power limit, reading, PV surplus | Room and hot water |
|---|---|---|---|
| Vaillant | VR 920, VR 921, VR 940f | reading, PV surplus; limit on some models | yes, zones 1–3 |
| Bosch Compress | K 40 RF gateway | limit, reading, PV surplus | PV hot water boost only |
| Buderus | MX400 module | limit, reading; PV surplus on WLW176i, WLW186i | PV hot water boost only |
| Viessmann Vitocal 250-A, 200-S | built in | limit, reading, meant for the grid operator | no |
| Wolf CHA, FHA | WOLF Link home or pro | limit, reading, PV surplus after a firmware update | PV hot water boost only |
| NIBE S-series | built in, firmware 4.5.7 or later | limit, reading; PV surplus from firmware 4.13.12 | not documented |
| Daikin Altherma 3, 4 | HomeHub EKRHH | limit, reading | no |
| Stiebel Eltron, Panasonic, Mitsubishi, Kermi, Ochsner, Ariston | no EEBUS found | — | — |

## Learn more

- [Vaillant heat pump in TapHome](https://taphome.com/en/ideas/vaillant-heat-pump/): temperatures, setpoints and energy over eBUS.
- [Energy Manager: steady switching](https://taphome.com/en/ideas/energy-manager-steady-switching/) and [Plan devices by tomorrow's electricity price](https://taphome.com/en/ideas/electricity-price-planning/).
- [EEBUS specifications](https://www.eebus.org/specifications/) describe all use cases of the standard.

Which heat pump or wallbox would you connect over EEBUS? Vote, follow this idea and answer the poll below.

**Vote · Follow:** Anyone can vote. Sign in with your TapHome account to follow ideas, answer polls, comment and suggest your own.