---
title: "Version 2026.1"
description: "TapHome 2026.1: new smart rule evaluation, device default values, Condition and Scheduler, a rebuilt Modbus slave and faster app connection."
url: "https://taphome.com/en/docs/release-notes/2026-1/"
language: en
lastmod: 2026-10-21
generator: hugo
ai:
  topics: ["release-notes","smart-rules","default-values","manual-override","universal-triggers","modbus-slave","permissions"]
  questions: ["What's new in TapHome 2026.1?","What happens to my smart rules when I update to version 2026.1?","How do I set what a device does when no smart rule controls it?","Which smart rules did the Condition smart rule replace?","Why does my Modbus TCP master get no response after the update?","Where do I find the list of phones and tablets connected to a location?","How do I give a user permission to only view a device?"]
---

# Version 2026.1

What's new in TapHome 2026.1: new smart rule evaluation, device default values, Condition and Scheduler, Read-only permission and faster connection.

Last updated: 2026-10-21

[2026.1 in interactive demos](https://taphome.com/en/whats-new/2026-1/) — See what changes. Try it right on the page.

> [!NOTE]
> Version 2026.1 is still in beta. The officially released version is 2025.2; a 2026.1 control unit works with the TapHome Next app ([before you update](https://taphome.com/en/docs/release-notes/2026-1/#before-update)).

Version 2026.1 is one of the largest TapHome updates. It brings a new way of evaluating smart rules, new and reworked smart rules, device default values, manual mode tracked separately for each value, new device types, the **Read-only** permission and a much faster app connection. Existing smart rules and device groups are converted to the new format automatically during the update.

## Much faster connection

The app connects noticeably faster when you return to it, change networks or switch locations, especially in large installations and over the cloud. It keeps a local copy of the location's devices, interfaces and values, and on reconnection the control unit sends only what has changed in the meantime instead of the whole list.

## **Default values** for devices

Devices with controllable values have a new **Default values** setting. It determines what happens to a value when nothing is controlling it — no smart rule, group or manual mode:

- **Do not change** — the value stays as it is;
- **Last manual value** — the last value from a manual change is restored;
- **Set to value** — the device goes to the value you enter.

After the update, all devices have the **Do not change** option. A light switched on by a motion sensor therefore stays on after the smart rule ends; if it should turn off, choose the **Set to value** option and enter 0%. The helper smart rule **Keep default values** is no longer needed for this — existing smart rules of this type remain and keep working.



The option applies to the whole device; use the **Show more** button in the dialog to set it for each value separately. Default values have the lowest priority and are always last in the **Affected by** section of the device detail. When a default value is currently in control of the device, the **Default value** mode icon shows it ([documentation](https://taphome.com/en/docs/smart-rules/default-values/)).

## Manual mode for each value separately

Manual and automatic modes are tracked separately for each value of a device. For example, when you change the brightness of a light manually, only the brightness goes into manual mode, and smart rules can keep controlling the color temperature. A smart rule action that sets several values at once, however, is performed in full or not at all: while the manual override time of the brightness runs, and always with the **Keep manual mode until ended by user** option, the light rejects the whole action with brightness and color temperature. When the values are in different modes, the device detail shows the mode next to each value; mode changes are written to the device log.

As before, set how long manual mode lasts in the device detail with the **Manual override** button. This setting and its time remain shared by all values of the device.



- New option **Keep manual mode for a limited time and then until next automatic change**: when the time runs out, the device does not switch back to automatic mode right away; manual mode lasts until the next automatic change.
- The new **Overriding automatic mode or default value is disabled** option rejects a manual change while a smart rule or the **Set to value** default holds the value; the existing **Do not allow manual mode** option prohibits manual changes completely.
- When you add a virtual device or change the type of a device, the app prefills the option by type — for example, a circulation pump gets the **Keep manual mode for a limited time** option set to 15 minutes.

## New smart rule evaluation

The **Affected by** section in the device detail used to show the device's smart rules in order of priority. It now also contains groups, default values and the **Manual control** row, so it is a single list of everything that affects the device. The order is the priority; as before, change it with the **Edit** button by moving the rows.

- Each value of a device is evaluated separately. A smart rule with a higher priority takes only the values it sets; smart rules with a lower priority can keep controlling the other values.
- Safety is no longer a separate type of smart rule but an action mode: every action can be in **Manual**, **Automatic** or **Safety** mode. Several safety smart rules can therefore act on one device at the same time, and their priority decides between them.
- Evaluation order: safety actions first, followed by a manual change from the app or directly on the device, then manual and automatic smart rule actions by priority, and default values last.
- The original safety smart rules keep the highest priority after the update.

For example, the **Protect blinds from wind** smart rule keeps the blinds raised in safety mode while the wind speed exceeds the strong wind threshold, and then works in automatic mode.

A smart rule can also be disabled for a single device with the **Disable on this device** option in the **Affected by** section or in the list of the smart rule's inputs and outputs; it keeps controlling the other devices.



## New and reworked smart rules

Several single-purpose smart rules have been replaced by more universal ones. They are converted automatically during the update:

| Original smart rule | After the update |
|:--|:--|
| **Push button event**, **Switch event**, **Notification**, **Doorbell ring action**, **Daily schedule** and others ([full list](https://taphome.com/en/docs/smart-rules/condition/#replaces)) | **Condition** |
| **Weekly schedule** | **Scheduler** |
| **Delayed start and end**, **Countdown timer** | **Delay** |
| **Lighting timer**, **Push button dimming** | **Light Controller** |
| **Temperature PID controller** | **PID controller**; switching and PWM outputs go to **Temperature hysteresis controller** |
| **Protect blinds from strong wind**, **Adjust blinds in windy conditions** | **Protect blinds from wind** |
| **Control blinds with single push button**, **Control blinds with Up and Down push buttons** | [**Control blinds with push buttons**](https://taphome.com/en/docs/smart-rules/push-button-blind-control/) |

**Condition** is a new smart rule that performs actions when a condition on a device value or a time condition is met (**Device value** or **Time** mode). It has an ordered list of [universal triggers](https://taphome.com/en/docs/release-notes/2026-1/#triggers), each with its own actions, and the first trigger that is met applies. For example, three triggers based on one temperature — heat at full power below 18 °C, at reduced power below 20 °C, and switch off at 21 °C and above — fit in a single smart rule. See the [**Condition**](https://taphome.com/en/docs/smart-rules/condition/) smart rule documentation for the setup.



1. The number in the circle is the order of the trigger; change it by moving the row. A filled circle marks a state trigger, a hollow one an event trigger.

Other new and reworked smart rules:

- **Scheduler** (replaces **Weekly schedule**) performs actions at specific times of a recurring period — day, week, workday and weekend, month or year. The times can be fixed or relative to sunrise or sunset; **Weekly schedule** had neither monthly and yearly repetition nor times based on the sun ([documentation](https://taphome.com/en/docs/smart-rules/scheduler/)).
- **Delay** (replaces **Delayed start and end** and **Countdown timer**) waits for the **Start delay** after it is triggered, performs the **Start actions** and holds them until the **End delay** expires; then it can perform the **End actions** ([documentation](https://taphome.com/en/docs/smart-rules/delay/)).
- **Light Controller** (replaces **Lighting timer** and **Push button dimming**) controls one or more lights with push buttons and sensors in one smart rule, including dimming by holding a button. New are the **Automatic turn off** section for presence sensors with an **Turn-off Delay** and custom push button actions for the lights of this smart rule, for example a double click activates a color scene; until now a push button could only turn on, turn off or toggle. For actions on other devices, use **Condition** ([documentation](https://taphome.com/en/docs/smart-rules/lighting-controller/)).
- **Energy manager** (new) turns devices on and off according to the surplus power measured by the electricity meter and according to their priority; it regulates analog outputs smoothly. For each device, you can set, for example, its power, minimum run time or active time intervals; the smart rule keeps the grid draw within the set limits. This lets water heating or pool filtration run mainly on solar surplus ([documentation](https://taphome.com/en/docs/energy-manager/)).
- **Open window notification** (new) sends a notification or performs actions when a window, door or garage gate stays open longer than the set time. It can be restricted by a presence device; by default, it is active in the Away and Vacation states ([documentation](https://taphome.com/en/docs/smart-rules/window-open-notification/)).
- **Protect blinds from wind** (reworked) handles both strong and mild wind in one smart rule; this used to take two. It protects against strong wind immediately in safety mode ([documentation](https://taphome.com/en/docs/smart-rules/protect-blinds-from-wind/)).
- **Blinds adjustment according to sun** (reworked) handles blinds with different service settings in the **Sun orientation** (window orientation relative to north, window height, distance from the floor to the window) or **Slats angle adjustment** sections in one smart rule. Such blinds used to need several smart rules ([documentation](https://taphome.com/en/docs/smart-rules/blinds-adjustment-according-to-sun/)).
- **PID controller** (reworked) regulates based on any device with a setpoint, not only temperature, and writes the correction to analog outputs, variables, blinds or thermostats. For each output, set the **Positive**, **Negative** or **Both** mode and a range from minimum to maximum; the heating and cooling mode can come from a device or be fixed. You can also use it with the new humidity, CO2 and water level controllers, for example.

## App

The TapHome desktop app has been rebuilt using new technology and is available for Windows, macOS and Linux. It renders more smoothly and adds:

- animated drag-and-drop reordering, with the list scrolling automatically;
- automatic switching between the light and dark themes according to the system;
- video playback from cameras;
- a **Remember password** option on the login screen (Windows and macOS): saved accounts are offered after you click into the user name or password field, can be removed from there, and passwords are stored encrypted.

The icon of a device, including the icons of individual Multi-Value Switch values, can be customized further once you have chosen it: **Appearance** (**Default**, **Black and white**, **Off** or **Accent color**), **Background** (**Circle** or **Square**), an **Overlay** with an adjustable position, and, for text icons from the **Text (editable)** category, your own text or emoji. A garage gate can, for example, have a lock in the corner of its icon ([documentation](https://taphome.com/en/docs/configuration/custom-icons/)).



A device on a scheme has a new **Controls** option in the **Visualization** section: its control buttons appear next to the device, and you control it from the scheme without opening the detail. From the statistics in a graph detail, the **Detail** item goes straight to the device detail.

Lists show the relations between devices and smart rules:

- the **All devices** list (also on interface pages) has a **Show affected by and assigned smart rules** switch in the menu; when you turn it on, each device shows its safety, affecting and assigned smart rules and limiting conditions, and disabled relations are gray;
- in the **Smart rules** list, the **Show inputs and outputs** switch shows the input and output devices of each smart rule;
- every smart rule has an **Inputs and outputs** page in its menu;
- the **All devices** list has a **Devices without a smart rule** overview.

Android displays the app edge to edge. On iOS, animations are smoother, synchronized with the display refresh rate.

## Devices

Existing device groups are converted to a single group type during the update, and **Settings** has its own **Device groups** item for groups. Groups of analog outputs and blinds could not be created since version 2023.1; the dialog for adding a group offers them again, together with groups of electricity meters and water meters.

- The calculation method of the group value is chosen for each value separately, for example MIN, MAX or AVG for analog outputs. A group of electricity or water meters used to always add up the values.
- The group has its own row in the **Affected by** section of each of its devices, and its command applies with the priority of that row: it does not change a value held by a smart rule higher in the list. A manual change directly on the device belongs to the **Manual control** row.
- When one of the group's devices is in error, the group reports its own error, **Group child device error**; until now, a group of meters or analog outputs took over the device's error. It also reports an error when groups refer to each other in a cycle.

A device made up of other devices — typically a group, but also an electricity meter with sub-meters or a virtual RGB light — has a **Devices** section in its detail, where you can open and control these devices directly.

The new virtual devices **Humidity controller**, **CO2 controller** and **Water level controller** have an adjustable setpoint. You assign them a sensor that supplies the current value, and the setpoint can be used in triggers and actions of smart rules — for example, the **PID controller** can regulate toward it.

Other device changes:

- The detail of every blind has quick actions: fully raising and lowering (0%, 100%, or 100% with the slats at 0%) and **Stop**.
- **Multi-State Sensor** is a new device type with named states: each numeric value has its own name and icon, up to 32 values. It can be created as a virtual device, in Packet parser and in Modbus.
- **Multi-Value Switch** can have up to 32 values instead of 10.
- If a device has a conversion, for example a variable converted to temperature, the converted value can also be changed manually in the detail, and the change is written back to the original value. Until now, the converted value in the detail was read-only.

**Settings** has a new **Client devices** section (for administrators and service technicians) listing all phones, tablets and computers that have connected to the location: name, platform and app version, online status, time of last access, and the **This device** label on the device you are using. **Settings** shows the number of currently connected devices directly. The detail of a client device also shows its creation time and identifiers, and the device can be renamed there — for example, the tablet at the entrance, which you can then pick as a recipient of [notifications](https://taphome.com/en/docs/release-notes/2026-1/#notifications).

## Notifications

**My location** has a **Test notification** item in the **Attributes** section, which immediately sends a test notification to selected users, groups or client devices. In the **Alarm** smart rule, you choose on which client devices the alarm will beep; until now it was a single device.

Every notification in any smart rule has the **Use fixed text** or **Generate content dynamically** option in the **Content settings** section. The dynamic title and message are created by the **Title script** and **Message script**, which can read device values as well as data such as the name of the smart rule or location — a notification about an open window can thus also state the outdoor temperature, for example. Older notifications with placeholders are converted to scripts automatically.

## **Read-only** permission for devices

Devices that are outputs (actuators) have a new **Read-only** permission level. A user with this permission sees the device, its values, graphs and statistics, but cannot change the values — for example, the thermostat setpoint. For devices, the previous lowest level, which allowed changing values, is called **Control**.

## Universal triggers

Smart rules have a new common trigger system: instead of the fixed conditions of individual smart rules, there is one flexible trigger that works the same everywhere. A trigger can be:

- **Device value** — either a state that applies while the condition lasts (for example **Value equals**, **Value is greater than**, **Value is within interval**, **Has no value**, **Has error**), or an event that fires once on a change (for example **Value changed to**, **Value rose above**, **Value fell below**, **Got error** or a push button press);
- **Time** — a specific time or a time interval in a recurring period (day, week, workday and weekend, month, year), also relative to sunrise or sunset.

A trigger can watch several devices at once (the **All devices must fulfill the state** option). In the **Additional settings** section, set the minimum and maximum duration, delay, delay queue and hysteresis.

For example, the **Value equals** state on a motion sensor keeps the light on while motion lasts, whereas the **Value changed to** event turns it on only once, at the moment motion starts.

Universal triggers are used by these smart rules:

- **Condition** — an ordered list of triggers, each with its own actions;
- **Formula** and **Script** — after you choose **On custom event**, the calculation or script does not run on every input change but on a universal trigger; until now, this event could only be a press of a single push button;
- **Delay** — the trigger determines the start and end of the cycle and watches device values only; the time settings of a trigger are not available here; the smart rule has its own two delays instead;
- **Sequencer** — in the **Controlled by triggers** mode, which replaces the previous push button control, the sequence is started, stopped, paused or restarted by triggers.

The condition types and other trigger settings are described on the [Triggers](https://taphome.com/en/docs/smart-rules/triggers/) page.

## **Timeline**

Until now, only **Weekly schedule** had a timeline. The **Timeline** section now shows time settings graphically over the whole period (day, week, month, year) in these smart rules:

- **Scheduler** — when each scheduled action will be active;
- **Limiting condition** of the **Time** type ([intervals](https://taphome.com/en/docs/release-notes/2026-1/#smart-rules-more)) — when the smart rule will work and when it will be limited;
- **Condition** in **Time** mode — when each trigger will be active, including which higher-priority trigger overrides the others.

Each action or trigger has its own color, which also colors its icon in the list below the timeline. Times tied to sunrise and sunset are drawn according to the actual time at the location, so for blinds that are raised at sunrise you can see how that time shifts through the year.

## More smart rule changes

- The **Equation** smart rule has time settings for both the **TRUE** and the **FALSE** result. For the **FALSE** result, there is a new minimum duration — the result stays **FALSE** for at least the set time, even if the condition is met in the meantime. For the **TRUE** result, there is a new **Reset maximum duration after** option.
- **Energy manager** and **Light Controller** keep their own log of decisions, for example, a device turned on and why, power exceeded, or an automatic turn-on by a sensor. The smart rule shows the latest entries; open the full log with the **Show all logs** button.
- In an action on a device, besides **Set value** you can also choose **Add** or **Subtract**: the new value is calculated from the current value of the device and stays within its range. This works, for example, for the position and slat angle of blinds, analog outputs, brightness, color, variables and setpoints of temperature, humidity, CO2 and water level — a push button can thus raise the brightness in steps.
- The **Limiting condition** of the **Time** type is no longer a single daily window: the smart rule works in the chosen intervals of a recurring period (day, week, workday and weekend, month, year), for example only in winter ([documentation](https://taphome.com/en/docs/smart-rules/limiting-condition/#time)).

## **Expose devices**

Exposing devices over **Modbus TCP**, **Modbus RTU** and **Modbus ASCII** (Modbus slave) has been completely rebuilt:

- Instead of a fixed block of 20 registers per device, you pick specific values and actions of the device, and each has its own register. For each one, set the register type (H, A, C, D), register index, data type, byte order and multiplier.
- Many more device types can be exposed — sensors (temperature, humidity, CO2, pressure, wind and more), electricity, gas and water meters, groups, controllers, color lights and more.
- The Modbus master can also trigger device actions, such as blind commands, not only write values.
- A validity register can be added to each value to tell the master whether the value is valid (for example, whether the device is available); when it is not, the configured fallback value is returned.
- Overlapping register ranges are shown in the interface detail, interface conflicts (the same port and Slave ID, a missing serial port) in the list of interfaces.
- Several Modbus TCP interfaces can share one port if they have different Slave IDs.

Existing Modbus slave interfaces are converted automatically during the update, keeping the same register addresses and Slave ID; the Stop register of some devices is not converted ([before you update](https://taphome.com/en/docs/release-notes/2026-1/#before-update)).

> [!WARNING]
> Modbus TCP now responds only to the Slave ID (Unit ID) set in the app. If your master has been sending a different Unit ID, for example 0 or 255, change it. Reading an address that is not assigned to any value returns an error.

The **TapHome API** interface can be added several times, each with its own token, and each one can be renamed — the name appears in the list of interfaces. The new **Read-only token** option creates a token that can only read device values, not change them. 

Integration protocol can also expose a **Multi-State Sensor**, and several clients can connect over **Integration protocol TCP** at the same time. Value changes are sent to each client with sending turned on: the interface's **Auto send (push all)** option is the default state of every new connection, and the client switches it with the `PUSHALL ON` or `PUSHALL OFF` command. 

## Scripts, Packet parser and Modbus

- **Value history.** In scripts (the **Formula** and **Script** smart rules, device scripts), you can choose the **Value info of**… variant of a value, and such a variable gives access to the previous value and its time (`Current.PreviousValue`, `Current.PreviousValueTime`, `Current.LastKnownValue` and more) and, for statistics, also to values from previous completed periods (`History.Values`, where `[0]` is the previous period).
- **Write verification.** For devices on the TapHome bus, the control unit compares the value read from the hardware with the written one after each write. If they do not match, it retries the write several times and then reports a device error, which disappears when the values match or a new value is written. Scripts in Packet parser and Modbus have a new `DEBOUNCE(deviceVariable, durationMillisec)` function, which ignores read values for the given time after a write, so the value does not jump back during the transition.
- **Block reading and writing of registers.** Modbus scripts have functions for a whole block of registers at once: `MODBUSRBLOCK(type, address, count)` reads a block in one request, `MODBUSWBLOCK(...)` writes it, and `MODBUSWBLOCKNE(...)` writes it only if it has changed. `UNPACKVALUE(...)` and `PACKVALUE(...)` read a value of a given data type (Int16, UInt16, Int32, UInt32, Int64, UInt64, Float, Double, Bool, String) from a block or write it into one, with an optional byte order; `PACKVALUE` does not write the String type. The `UINT16COLLECTION(count)` and `BOOLCOLLECTION(count)` functions create a collection. Variables of Modbus devices can have the `collection<uint16>` or `collection<bool>` type and hold a whole block of registers.
- **Modbus RTU over TCP.** The **Modbus TCP** interface has a new **Modbus RTU over TCP** option for transparent serial-to-Ethernet converters that tunnel RS485 unchanged. 

## Fixes and improvements

- Faster rendering of lists and schemes.
- The TapHome bus reconnects automatically after the USB port is disconnected and connected again.
- More stable communication over Integration protocol (UDP and TCP).

---



## Before you update

- A 2026.1 control unit does not connect to the TapHome app 2025.2 or older. Install the TapHome Next app on all phones, tablets and computers — version 2026.1 is in the stores for Android 6.0 and later, iOS, macOS and Windows.
- The device permission that used to be called **Read-only** and allowed changing values is now called **Control**. The new **Read-only** does not allow changing values, and no saved permission is converted to it ([permission](https://taphome.com/en/docs/release-notes/2026-1/#permissions)).
- **Lighting timer** is converted to **Light Controller** with all sensors in the **Automatic turn on** section. Move the **Presence** signal to the **Automatic turn off** section ([documentation](https://taphome.com/en/docs/smart-rules/lighting-controller/#presence-usage)).
- A converted group gets a row in the **Affected by** section of each of its devices, placed just above the default values. A group command therefore does not change a value held by a smart rule higher in the list ([groups](https://taphome.com/en/docs/release-notes/2026-1/#devices)).
- When Modbus slave interfaces are converted, the Stop register of a KNX blind, of a Packet parser blind and **Awning** device, and of a virtual **Awning** device is not converted. A master that used it gets exception 0x02 at its address ([Modbus slave](https://taphome.com/en/docs/release-notes/2026-1/#expose-devices)).
