title: "Blinds Calibration Wizard"
description: "Calibrate blind timing in 3 steps with the TapHome wizard: motor startup time, travel time and slat angle time, so the app shows the real position."
url: "https://taphome.com/en/docs/functional-areas/blinds-slides-awnings/blinds-calibration-wizard/"
language: en
lastmod: 2026-11-06
generator: hugo
ai:
  topics: ["blinds-calibration","timing-parameters","motor-startup-compensation","travel-time-calibration","blade-angle-calibration","position-drift-correction"]
  questions: ["How do I start the blinds calibration wizard in TapHome?","Why do my blinds drift to one extreme position over time?","How do I calibrate motor startup compensation time for blinds?","What is the acceptable variance threshold for blind position calibration?","What increment size should I use when adjusting startup time?","How do I know when blinds with mechanical end-stops have finished moving?","What are the positioning options for angle calibration - 20% or 80%?"]
---

# Blinds Calibration Wizard

Detailed guide for calibrating blind timing parameters using the TapHome application wizard

Last updated: 2026-11-06

The Blinds Calibration Wizard in the TapHome application sets the blind timing parameters in three steps (motor startup duration, travel time from top to bottom and back, and angle duration), so that the position shown in the application matches the real position of the blinds. You start it with the **Start wizard** button in the blinds service settings, and during calibration it modifies the blinds timer parameters. You need access to the blinds service settings in the application and a sticker to mark positions. The result is correctly set timing values that keep the blinds from drifting toward one extreme position over time.

## Blinds calibration wizard

This wizard helps installers properly calibrate blind timing settings. Incorrect parameters typically cause blinds to drift toward one extreme position over extended use, resulting in actual blind position differing from the application display.

### Starting the Wizard

Navigate to blinds service settings and select the **Start wizard** button to begin calibration. The wizard will modify the blinds timer parameters during its operation.

![Start wizard button](https://taphome.com/documentation/blinds-wizard/StartWizard.png)

> [!WARNING]
> **Important Notice**
>
> **Make sure you are connected to the installation locally (wifi / cable) and not via data (4G). You also need to run the wizard without active SR on the device.**

### Three-Step Calibration Process

![Wizard page](https://taphome.com/documentation/blinds-wizard/WizardPage.png)

#### Step 1: Calibrate Motor Startup Duration

**Objective:** Measure the time required for the motor to begin moving.

![Move up button](https://taphome.com/documentation/blinds-wizard/MoveUp.png)

1. Ensure blinds are fully raised
2. Use the **Move up** button to adjust position
3. Click **Next** when ready
4. Blinds will descend for 10 seconds - **mark the final position with a sticker**
5. Blinds return to top position
6. System descends again in 20 small increments
7. Compare actual position against marked location
8. Adjust startup time:
   - **Increase** the value if motor didn't reach the mark
   - **Decrease** the value if motor exceeded the mark
9. Use small increments (5-10 ms)
10. Repeat until position variance is under 5 mm
11. Click **Finish** to continue

![Step 2 of 5](https://taphome.com/documentation/blinds-wizard/Step2-5.png)

![Step 3 of 5](https://taphome.com/documentation/blinds-wizard/Step3-5.png)

![Step 4 of 5](https://taphome.com/documentation/blinds-wizard/Step4-5_finish.png)

![Step 5 of 5](https://taphome.com/documentation/blinds-wizard/Step5-5.png)

> [!TIP]
> **Practical Tip**
>
> Precise calibration of motor startup time is crucial for proper functioning of all other parameters. Take sufficient time with this step.

#### Step 2: **Calibrate level duration time**

**Objective:** Measure complete top-to-bottom travel time and vice versa.

![Level step 1 of 3](https://taphome.com/documentation/blinds-wizard/LevelStep1-3.png)

1. Verify blinds are at top position
2. Click **"Move for 10 seconds"** until blinds approach bottom position (but not fully down)
3. Use **"Move for 1 second"** for fine tuning
4. Fine-tune with 0.1-second increments to reach exact bottom position
5. For mechanically stopped blinds, listen for relay click before stopping timer
6. Click **Next** when blinds are at bottom position
7. Repeat the procedure for upward movement
8. Click **Finish** when blinds reach top with accurate timing

![Level step 2 of 3](https://taphome.com/documentation/blinds-wizard/LevelStep2-3.png)

![Level step 3 of 3](https://taphome.com/documentation/blinds-wizard/LevelStep3-3.png)

> [!NOTE]
> **Note for Different Blind Types**
>
> Some blinds have mechanical end-stops, others use timing. Adapt calibration to your blind type. Upward travel typically requires slightly more time than downward movement.

#### Step 3: **Calibrate angle duration time**

**Objective:** Set blade rotation timing parameters.

![Angle step 1 of 3](https://taphome.com/documentation/blinds-wizard/Angle_Step1-3.png)

1. Confirm blinds are in raised position
2. **Please choose the position at which the angle will be calibrated.**
   - **"Move close to top"**: Positions at 20% level time or 5 seconds (whichever is smaller)
   - **"Move close to bottom"**: Positions at 80% level time or 5 seconds from bottom (recommended)
   - **"Move down"**: Manual adjustment with 1-second increments per click

![Angle step 2 of 3](https://taphome.com/documentation/blinds-wizard/AngleStep2-3.png)

3. Click **"Test angle"** to verify blade adjustment
4. Mark position with a sticker
5. Run **"Repeat angle test"** to check for cumulative errors across multiple adjustments
6. Click **Finish** when blinds maintain position through angle changes

![Angle step 3 of 3](https://taphome.com/documentation/blinds-wizard/AngleStep3-3.png)

> [!TIP]
> **Calibration Verification**
>
> After completing calibration, test the blinds in real-world usage. Verify that the position in the application matches the actual position even after multiple movements.

### Related Topics

- [Blinds, Slides, Awnings - Basic Configuration](https://taphome.com/en/docs/functional-areas/)
- [Blind Azimuth Adjustment](https://taphome.com/en/docs/functional-areas/blinds-slides-awnings/blinds-azimuth/)
- [Editing Multiple Devices](https://taphome.com/en/docs/configuration/editing-multiple-devices/)

### Video Tutorial

[YouTube video](https://www.youtube.com/watch?v=I3pillskAaw)

---

**Note:** This guide is part of TapHome documentation. For more information, contact technical support.

**See also** — [DC blinds with Encoder](https://taphome.com/en/docs/functional-areas/blinds-slides-awnings/encoder/), [Push Button Blind Control](https://taphome.com/en/docs/smart-rules/push-button-blind-control/).