The SolaX HAC Cloud API template connects TapHome to a SolaX X1-HAC or X3-HAC EV charger through the SolaX Developer Portal API (OpenAPI). The template author lists the A1-HAC and C1/C3-HAC chargers as well. TapHome does not talk to the charger directly: the charger reports to SolaXCloud over Wi-Fi, LAN or 4G, and TapHome reads its data from the SolaX cloud over HTTPS every 60 seconds. Write commands (work mode, start and stop, lock, current limit) go back to the charger through the cloud the same way.
Two things have to be in place before the template is imported. The charger must be online in a SolaXCloud account, and that account needs an application in the SolaX Developer Portal that provides the Client ID and Client Secret. If the charger works next to a SolaX inverter, the SolaX Inverter (Cloud API) template can run in the same TapHome project. It uses the older SolaxCloud monitoring API with its own token.
Connecting the charger to SolaXCloud
Network connection
The charger offers three ways to reach the internet. All of them use DHCP, so the router assigns the IP address automatically.
- Wi-Fi: 2.4 GHz only (802.11 b/g/n). 5 GHz networks are not supported.
- Ethernet (LAN): the RJ45 port LAN (/ DI). Ethernet uses pins 1, 2, 3 and 6 (TX+, TX−, RX+, RX−). Leave the other pins unconnected when only Ethernet is needed. With a LAN connection the Wi-Fi setup can be skipped.
- 4G: only for models with “4G” in the name (for example X3-HAC-22P-B4G). An authorized professional must install a nano SIM card that supports Cat-M, NB-IoT or GSM. SolaX recommends at least 100 MB of data per month in the Solar and Standard scenes.

The Ethernet cable to the charger must be protected against lightning strikes. If the LAN and the DI signal input are both needed, crimp pins 1, 2, 3 and 6 for Ethernet and pins 4, 5 and 8 for DI, then join the two cables with the RJ45 coupler supplied with the charger.
The 4G connection is configured in the SolaXCloud app in local mode: open Dongle, then the settings button, set Device Networking Mode to 4G, enter the operator’s APN and choose the network deployment the SIM supports.
Adding the charger in the SolaXCloud app
- Install the SolaXCloud app from the App Store or Google Play and register an account with an e-mail address or phone number and a verification code.
- On the first login, create a plant: allow location access, enter a plant name and complete the other settings.
- Add the charger by scanning or typing the Registration No. from its type label. Chargers added later go through the Device page, the + icon, then Add Device or Scan.
- Enter the Wi-Fi name and password if the charger connects over Wi-Fi.

The type label shows two different numbers. The Registration No. is used to add the charger in the app and to log in locally. The SN (device serial number) is what the TapHome template needs as DeviceSN. The app shows the device SN on the charger’s Basic information page (tap the top part of the charger’s Details page). It is also listed in the Developer Portal under Device > Device List.
Reconnecting Wi-Fi and local access
If the charger goes offline, open the Device page in the app, tap the charger card marked offline and choose Reconfigure. Then enter the 2.4 GHz network and password again.

If reconfiguration fails, there is a second way. Connect a phone or laptop to the charger’s own Wi-Fi network, which is named after its Registration No. (Wifi_XC…). Then open http://192.168.10.10/ in a browser and log in as admin, with the Registration No. as the password. Local mode in the app (More > Local Access, or Service > Application > Local Access when logged in) uses the same network.
The charger switches its local Wi-Fi network off automatically one hour after it connects to the network successfully. To use local access later, turn the network back on in the app under Network > Local Access.
Application scene and charging modes
The charger works in one of three application scenes, chosen in the app under Advanced setting > Application scene:
- Solar (default): the Green, Eco and Fast charging modes are available. Green and Eco need the charger to communicate with the inverter, or with a CT or meter on the grid connection, so that it knows the PV surplus.
- Standard: the charger only starts and stops charging. Green and Eco do not exist in this scene.
- OCPP: the charger is managed through an OCPP server, and the SolaXCloud app hides the mode selection.

The inverter connects to port COM1-S- (A1/B1). A meter or CT connects to port COM2-M- (A2/B2, CT inputs on the other pins). The charging current level for Green mode (3 A or 6 A) and for Eco mode (6, 10, 16, 20 or 25 A) is set in the app under Details > Function Control > Charge Level. On 11 kW models, Eco offers only 6 A and 10 A. Green and Eco charging also require a vehicle that complies with IEC 61851.
Setting up API access in the SolaX Developer Portal
- Sign in to the SolaX Developer Portal and open Quick Start or Application.
- Create an application for the SolaXCloud plant that contains the charger. The application must have at least one authorized plant.
- In the application’s Authorization tab, copy the Client ID and Client Secret.
- Under Service API > Authorize, enable the monitoring services Data Monitoring Service (
API_Telemetry_V2) and Information Access Service (API_Info_V2). Enable the EV charger control service as well, which the work mode switch and the service actions need. Monitoring alone works without it. - Find the charger’s serial number under Device > Device List. It is the same SN as in the SolaXCloud app.
The template is set to the European API host
openapi-eu.solaxcloud.com. SolaX runs separate hosts for China (openapi-cn.solaxcloud.com) and India (openapi-in.solaxcloud.com). The region of the account is shown in the Developer Portal. The template does not work, as imported, with an application in another region.
Import parameters
In TapHome, import the template and fill in the three parameters below. Everything else (token, polling, retries) is handled by the module.
| Parameter | Description | Where to find it |
|---|---|---|
ClientId | Client ID of the Developer Portal application | Application > Authorization |
ClientSecret | Client Secret of the same application | Application > Authorization |
DeviceSN | Serial number of the charger (not the Registration No.) | Developer Portal Device > Device List, or Basic information in the SolaXCloud app |
Use one Client ID and Client Secret pair for only one client. Each application has only one valid access token, so a new token request cancels the previous one. A second TapHome template instance, or another tool polling with the same credentials, keeps cancelling this template’s token. For a second charger, or for another system, create a separate application in the Developer Portal.
Device capabilities
The device names in the template are in Slovak. Each one is shown below with its name in the app in brackets.
Charging power and energy
Charging power (Nabíjací výkon) is an electricity meter. It shows the current charging power in kW and the total charged energy in kWh. Its service attributes show the energy of the current session (Energia aktuálnej relácie [kWh]), the phase currents L1, L2 and L3 (Prúd L1 [A], Prúd L2 [A], Prúd L3 [A]) and the single-phase current (Jednofázový prúd [A]).
Charging state and status code
- Charging in progress (
Nabíjanie prebieha) is a contact. It is on (Nabíja) only while the charger reports the status Charging. In every other status it is off (Nenabíja), including Suspended EV and Suspended EVSE. - Charger status (
Stav nabíjačky) is the raw status code of the charger:
| Code | Status | Code | Status |
|---|---|---|---|
| 0 | Available | 7 | Suspended EV |
| 1 | Preparing | 8 | Suspended EVSE |
| 2 | Charging | 9 | Update |
| 3 | Finishing | 10 | Card Activation |
| 4 | Faulted | 11 | Start Delay |
| 5 | Unavailable | 12 | Charge Pause |
| 6 | Reserved | 13 | Stopping |
Work mode
Work mode (Pracovný režim) is a multi-value switch with four values: STOP, FAST, ECO and GREEN. It reads the current mode of the charger and sets a new one from TapHome. ECO and GREEN behave as described in the Solar scene above and depend on the charger’s communication with the inverter or the meter.
Service actions
The charger status device carries four service actions:
- Start charging (
Spustiť nabíjanie) and Stop charging (Zastaviť nabíjanie). - Lock / make available (
Zamknúť / sprístupniť nabíjačku), with the values Lock (Zamknúť) and Make available (Sprístupniť). - Set current limit (
Nastaviť limit prúdu): 6–32 A on the 7 kW and 22 kW models, 6–16 A on the 11 kW model.
The commands are asynchronous. The answer “OK, príkaz odoslaný” means the SolaX cloud accepted the command, not that the charger has already carried it out. The result shows up in the readings of the next cycles.
Card and session history in Charts
- RFID card (
RFID karta) shows the number of the card that started the session, or 0 when no card is used. - Session charging time (
Čas nabíjania relácie) shows the duration of the current session in minutes.
The SolaX API does not provide a card history. With Charts enabled on these two variables, TapHome builds the history itself: which card charged, when and for how long, with a resolution of 60 seconds. Cards are only used when the charger’s activation mode is set to RFID in the SolaXCloud app (Charger setting > Activation mode). The default Plug & Charge mode uses no card.
Troubleshooting
No data, or an authentication error on the module
- Check that the charger is online in the SolaXCloud app. The server icon on the charger’s screen shows whether it is connected to SolaXCloud.
- Check
ClientIdandClientSecretagainst the Authorization tab. A secret regenerated in the portal has to be entered again. - Check that
DeviceSNis the charger’s serial number, not the Registration No. - Check that the application has an authorized plant with the charger and that the monitoring services are authorized. An API code 10403 means that the API service has no access rights. A code 10500 means that the application has no permission for this device’s data.
- Codes 10400 and 10402 mean the token is not valid. The module requests a new token and repeats the reading in the same cycle. If the module still reports an error with the text “aj po obnove tokenu” (“even after renewing the token”), the credentials or the authorized services are wrong.
Readings stop changing
Codes 10405 and 10406 mean that the API call limit has been reached. The module shows a warning and keeps the values from the last successful cycle. The template makes one request per minute. Other tools reading the same SolaX account count toward the same limit.
Work mode or actions fail
- A service action returns the text
SolaX API kód <code>when the cloud rejects the command. A code 10403 (no access rights to the interface) can mean that the EV charger control service is not authorized for the application. - ECO and GREEN only work in the Solar scene and need a working connection to the inverter or the CT/meter. In the Standard scene the charger only starts and stops charging.
Commercial installations
The template reads the charger as part of a residential plant (businessType=1). According to the template author, a charger in a commercial and industrial plant needs the value 4, and its power values are then in kW instead of W.