title: "Shelly UNI"
description: "Shelly UNI I/O module in TapHome over MQTT: two potential-free outputs, two digital inputs and one ADC voltage input. Gen1 device, MQTT set in web UI."
url: "https://taphome.com/en/compatibility/shelly-uni-mqtt/"
language: en
lastmod: 2026-10-08
generator: hugo
ai:
  topics: ["mqtt","i/o-module","shelly","gen1","wifi","low-voltage"]
  questions: ["How to integrate Shelly UNI with TapHome via MQTT?","What does the Shelly UNI TapHome template control and measure?","How to connect potential-free outputs of Shelly UNI to a real load?","Why does my Shelly UNI reed contact show inverted state in TapHome?","What voltage range can I measure on the Shelly UNI ADC input?","Can Shelly UNI read DS18B20 temperature or DHT22 humidity sensors in TapHome?"]
---

# Shelly UNI

Communication: Packet Parser → MQTT

- [Shelly UNI Knowledge Base](https://kb.shelly.cloud/knowledge-base/shelly-uni)
- [Shelly UNI Documentation](https://www.shelly.com/blogs/documentation/shelly-uni)

> Network address
> 
> With the MQTT broker built into TapHome, it is one broker reached from two places. The template runs directly in the TapHome Core, so in TapHome the broker address is `127.0.0.1` (this computer). The device runs elsewhere in the network, so in the device enter the IP address of the TapHome Core and give the Core an IP reservation in the router — if the Core’s address changes, the device can no longer reach the broker.
> 
> [Network Preparation](https://taphome.com/en/docs/setup/network-preparation/)

## Integration guide

The Shelly UNI is a compact universal Wi-Fi I/O module (20 × 33 × 13 mm) from the Shelly Gen1 platform. It provides one ADC voltage input, two potential-free open-collector outputs and two digital inputs — designed to retrofit legacy appliances without a hub.

TapHome communicates with the device over MQTT. The template subscribes to the `shellies/<prefix>/...` topic tree and publishes commands to `.../relay/{0,1}/command`. The module exposes 5 devices: 1 analog input, 2 switches and 2 reed contacts.

## Hardware connection

### Power supply

Shelly UNI is a **low-voltage module** and cannot be powered directly from the 230 V mains. Supply either:

- **12–36 V DC** via Red (+) and Black (GND), or
- **12–24 V AC** via Red and Black (no polarity)

An external low-voltage power adapter is required. Device consumption is below 1 W.

> [!WARNING]
> Do not connect the Red/Black leads to mains voltage. Hazardous voltage may still be present on the IN_1 / IN_2 / OUT1 / OUT2 terminals depending on the external circuit — installation must be performed by a qualified electrician.

### Pigtail wiring legend

The device ships with a color-coded pigtail cable:

| Wire | Terminal | Function |
|------|----------|----------|
| Red | VCC | 12–36 V DC (or 12–24 V AC together with Black) |
| Black | GND | Ground (or AC phase with Red) |
| White | ADC_IN | Analog input (0–12 V or 0–30 V range) |
| Yellow | VCC_SENSOR | 3.3 V DC output for one-wire sensors |
| Blue | DATA_SENSOR | One-wire data (DS18B20 / DHT22) |
| Green | GND_SENSOR | Sensor ground |
| Light brown | IN_1 | Digital input 1 |
| Dark brown | IN_2 | Digital input 2 |

The two potential-free outputs are marked `OUT1` and `OUT2` on the module body.

### Digital inputs (IN_1, IN_2)

Each digital input is potential-free and can be driven by either a DC or AC source:

- **DC:** HIGH when ≥ 2.2 V, LOW below 2.2 V, max 36 V DC
- **AC:** HIGH when ≥ 12 V, LOW below 12 V, max 24 V AC

Typical use cases are **reed contacts** (window/door sensors, float switches) and **push-buttons** shorting the input to GND through an external supply.

![Shelly UNI reed contact wiring with DC supply](https://taphome.com/images/compatibility/shelly-uni-mqtt/wiring-reed-contact-dc_hu_4be040d051e42061.jpg)

![Shelly UNI reed contact wiring with AC supply](https://taphome.com/images/compatibility/shelly-uni-mqtt/wiring-reed-contact-ac_hu_425daade8b447828.jpg)

![Shelly UNI button/switch wiring with DC supply](https://taphome.com/images/compatibility/shelly-uni-mqtt/wiring-button-switch-dc_hu_c95c9802866cc9c7.jpg)

![Shelly UNI button/switch wiring with AC supply](https://taphome.com/images/compatibility/shelly-uni-mqtt/wiring-button-switch-ac_hu_f9d3f31ed08b9743.jpg)

### Potential-free outputs (OUT1, OUT2)

Each output is an **open-collector, potential-free contact** with the following absolute limits:

- **100 mA** maximum current
- **300 mW** maximum power
- **24 V AC** or **36 V DC** maximum switched voltage

These ratings are too low for mains loads — to switch real loads (lights, pumps, valves) connect the outputs to an **external relay or contactor** and power that relay's coil from a matching low-voltage source.

![Shelly UNI potential-free output wiring diagram](https://taphome.com/images/compatibility/shelly-uni-mqtt/wiring-load-output_hu_5cd4aa406bacbcc0.jpg)

### Analog input (ADC)

A single ADC channel on the White (ADC_IN) lead supports two voltage ranges, selectable in the Shelly web UI:

- **0–12 V** — higher resolution for low-voltage signals
- **0–30 V** — wider range for battery / DC-link monitoring

The selected range is stored on the device only — the TapHome template reads the raw published value and cannot detect which range is active. Make sure the Shelly ADC range matches the signal you wire to the White lead.

![Shelly UNI ADC input wiring diagram](https://taphome.com/images/compatibility/shelly-uni-mqtt/wiring-adc-input_hu_b1b1677c93ad99cb.jpg)

## Configuration

### Device ID and MQTT prefix

Each Shelly UNI has a unique **Shelly-ID** equal to the last 6 characters of its MAC address (e.g. `35FA58`). The resulting MQTT topic prefix is `shellyuni-<Shelly-ID>` (e.g. `shellyuni-35fa58`).

The Shelly-ID can be found:

- On the device label (MAC address)
- In the Shelly web UI: **Settings** → **Device Info**
- Via API: `GET http://<device-ip>/settings` → `device.hostname` field

> [!TIP]
> Shelly Gen1 devices advertise themselves via mDNS as `shellyuni-<Shelly-ID>.local`. You can use this hostname instead of a fixed IP address to reach the web UI.

### Enabling MQTT

On a fresh device, MQTT is disabled. Enable it before importing the TapHome template:

1. Connect to the device's access point `shellyuni-XXXXXX` (password printed on the device) or reach it on your LAN
2. Open the web UI at `http://192.168.33.1/` (AP mode) or the LAN IP
3. Go to **Internet & Security** → **Advanced — Developer Settings**
4. Check **Enable action execution via MQTT**
5. Set the broker IP and port (default `1883`), leave username and password empty — TapHome does **not** support MQTT authentication on Gen1
6. Save and reboot the device

> [!WARNING]
> Enabling MQTT **disables the Shelly Cloud connection** on Gen1 devices. This is by design — the device cannot maintain both connections simultaneously. The Shelly mobile app will no longer control the device over the cloud; use MQTT or the local web UI instead.

> [!WARNING]
> Shelly Gen1 devices do **not** support MQTT over TLS. Communication between the device and the broker is unencrypted (plain MQTT, port 1883). Keep the broker on a trusted local network.

### Template setup

When importing the template into TapHome, supply:

- **IpAddress** — MQTT broker IP
- **Port** — broker port (default `1883`)
- **DeviceID** — the 6-character Shelly-ID of the specific UNI (e.g. `35fa58`)

The `DeviceID` import parameter is used to build the `MQTTprefix` custom variable (default `shellyuni-$[DeviceID]`). If you have set a custom `mqtt_id` on the Shelly device (overriding the default), edit the `MQTTprefix` variable on the module after import to match.

> [!TIP]
> Disable HTTP authentication on the Shelly device (**Internet & Security** → **Restrict Login**). TapHome does not use HTTP on this template, but leaving auth enabled can complicate troubleshooting and firmware updates.

## Device capabilities

### Analog voltage measurement

The **Analog Input** device reads the ADC voltage from `shellies/<prefix>/adc/0` and exposes it as a numeric value in volts. The script parses the incoming payload with `TODOUBLE(TOSTRING(PAYLOAD))` — no scaling is applied.

The actual measurement range (0–12 V or 0–30 V) is configured on the Shelly device itself and is not reported over MQTT. The TapHome template cannot verify which range is active.

### Switch outputs

Both open-collector outputs are exposed as standard TapHome Switch devices:

- **Switch 1** — OUT_1, topic `shellies/<prefix>/relay/0`, command topic `.../relay/0/command`
- **Switch 2** — OUT_2, topic `shellies/<prefix>/relay/1`, command topic `.../relay/1/command`

The listener maps payload `on` → ON (St=1) and `off` → OFF (St=0). Commands from TapHome are published as `on` / `off` on the respective command topic.

> [!WARNING]
> The outputs are potential-free and limited to 100 mA / 300 mW. Do not connect mains loads directly — use an external relay or contactor for anything heavier than low-power signaling devices.

### Digital inputs (reed contacts)

Both digital inputs are exposed as Reed Contact devices with **inverted logic**:

- **Reed Contact 1** — IN_1, topic `shellies/<prefix>/input/0`
- **Reed Contact 2** — IN_2, topic `shellies/<prefix>/input/1`

The Shelly firmware publishes `1` when the input sees a voltage above its threshold and `0` when the input is pulled to GND. Since reed contacts and push-buttons typically short the input to GND in the **closed / active** state, the TapHome script inverts the payload:

```taphome
Rc := IF(payload = "0", 1, 0)
```

This means `Rc=1` in TapHome = contact closed (active, window open sensor triggered, button pressed), `Rc=0` = contact open (inactive).

### Additional capabilities

The Shelly UNI hardware also supports up to **3 × DS18B20** temperature sensors on the one-wire bus and — as an alternative — **1 × DHT22** humidity/temperature sensor. These sensors publish on `shellies/<prefix>/ext_temperature/{0,1,2}` and `shellies/<prefix>/ext_humidity/0`. The current MQTT template does not wire these topics into TapHome devices; they can be added in a future template update.

Similarly, the device exposes an **online/offline LWT** topic and short/long-press **input events** on `input_event/{0,1}` that are not consumed by this template.

> [!TIP]
> For scene triggers based on button events (short press, long press), the `input_event` topic can be subscribed to from a separate MQTT client today — the TapHome template only tracks the raw input state.

## Troubleshooting

### Device not responding

1. Verify the Shelly UNI is powered (Red/Black on 12–36 V DC or 12–24 V AC) and connected to Wi-Fi
2. Open the Shelly web UI via the mDNS hostname `shellyuni-<Shelly-ID>.local` or its DHCP IP
3. Confirm MQTT is enabled (**Internet & Security** → **Advanced — Developer Settings**) and the broker IP/port match the TapHome import parameters
4. Use an MQTT client (e.g. MQTT Explorer) to subscribe to `shellies/#` and verify the device publishes messages

### Switches do not toggle

1. Check the command topic path — it must be `shellies/<prefix>/relay/0/command` (not `.../relay/0/set`)
2. Confirm that the TapHome module's `MQTTprefix` variable matches the topic prefix the device actually publishes on
3. Remember that the outputs are potential-free — without an external circuit supplying voltage, the output state changes but no load switches

### Reed contact state is reversed

The template expects `payload=0` to mean "contact closed". If your external wiring pulls the input HIGH when the contact is active (inverse wiring), the state will appear reversed in TapHome. Rewire so that the contact **shorts IN_1 / IN_2 to GND** when active, or adjust the logic in a custom script.

### ADC value out of expected range

The ADC range (0–12 V or 0–30 V) is set on the device and cannot be read back over MQTT. If the numeric value in TapHome looks wrong (e.g. 2× higher or lower than expected), open the Shelly web UI and check **Settings** → **ADC range**. The template assumes the device publishes the voltage directly and does no conversion.

## How to install in TapHome

### Prerequisites

- Shelly device connected to Wi-Fi (2.4 GHz), e.g. through the Shelly app or the device's own access point
- MQTT broker running on your local network (e.g., Mosquitto, Home Assistant, or TapHome built-in broker)
- TapHome CCU on the same network as the broker

> [!WARNING]
> On **Gen1** devices, enabling MQTT **disables Shelly Cloud**. Both cannot run simultaneously. On Gen2/Plus devices this limitation does not apply.

### Step 1 — Enable MQTT on the Shelly device

#### Gen1 devices (Shelly 1, 1PM, 2.5, EM, 3EM, Plug S, RGBW2, Dimmer, TRV…)

1. Open the Shelly web UI: `http://<device-ip>/`
2. Navigate to **Internet & Security** → **Advanced — MQTT**
3. Enable **MQTT**
4. Set **MQTT Server**: `<broker-ip>:<port>` (e.g., `192.168.1.10:1883`)
5. Optionally set **MQTT User** and **MQTT Password** if your broker requires authentication
6. Click **Save** — the device will reboot and connect to the broker

#### Gen2 / Plus devices (Shelly Plus 1, Plus 1PM, Plus 2PM, Plus Plug S, Plus H&T, Pro 3EM…)

1. Open the Shelly web UI: `http://<device-ip>/`
2. Navigate to **Settings** → **MQTT**
3. Enable **MQTT**
4. Set **Server**: `<broker-ip>:<port>` (e.g., `192.168.1.10:1883`)
5. The **Client ID** is pre-filled with the device ID (e.g., `shellyplus1pm-AABBCCDDEE`) — leave as-is unless you have a specific reason to change it
6. Click **Save** and reboot the device

With the TapHome built-in broker, `<broker-ip>` is the IP address of the TapHome Core. Give the Core an IP reservation in the router, otherwise the device loses the broker when the router changes the address → [Network Preparation](https://taphome.com/en/docs/setup/network-preparation/).

> [!TIP]
> To verify MQTT is working, use an MQTT client (e.g., MQTT Explorer) and subscribe to `shellies/#` (Gen1) or `<device-id>/#` (Gen2). You should see status messages from the device.

### Step 2 — Find the Device ID / MQTT Client ID

Some templates require a **Device ID** or **MQTT Client ID** parameter. This is the unique identifier used in MQTT topics.

- **Gen1:** found on the label as MAC address (e.g., `AABBCCDDEE`). Device ID = `shelly<model>-<mac>`, e.g., `shelly1pm-AABBCCDDEE`
- **Gen2/Plus:** found in the Shelly web UI under **Settings** → **Device Info** → **Device ID**, or on the device label

### Step 3 — Configure in TapHome

1. In TapHome, add a new **Packet Parser (MQTT)** module
2. **IP Address:** `127.0.0.1` for the TapHome built-in broker (the control unit connects to itself, the address never changes); for an external broker its IP address (e.g., `192.168.1.10`)
3. **Port:** `1883` (default; use `8883` for TLS)
4. **Device ID / MQTT Client ID:** enter the value from Step 2 (if required by the template)
5. Import the template — TapHome will subscribe to the device topics automatically

## Available devices 5

These devices appear in TapHome after import.

Shelly UNI Module

Custom Variables

`MQTTprefix` (string) = shellyuni-$\[DeviceID] MQTT topic prefix of the Shelly UNI device — defaults to shellyuni-{DeviceID} and is used as the base for all subscribed/published topics

Pass DeviceID as import parameter; find it in the Shelly web UI → Settings → Device Info (last 6 characters of MAC address). Custom mqtt\_id set on the Shelly device overrides this default.

Analog Input Variable Read-only

ADC voltage measurement — dual-range 0–12 V or 0–30 V, selected on the device

numeric Unit: V

Listener

```taphome
if RECEIVEDMSG.TOPIC = "shellies/" + MQTTprefix + "/adc/0"
    Va := TODOUBLE(TOSTRING(RECEIVEDMSG.PAYLOAD));
end
```

Switch 1 Switch Read and write

Potential-free open-collector output OUT\_1 — max 100 mA / 300 mW, 24 V AC or 36 V DC

string

Values / States: ON · OFF

Write switch state

```taphome
MQTTPUBLISH("shellies/" + MQTTprefix + "/relay/0/command", if(St, "on", "off"))
```

Listener

```taphome
if RECEIVEDMSG.TOPIC = "shellies/" + MQTTprefix + "/relay/0"
    VAR payload := TOSTRING(RECEIVEDMSG.PAYLOAD);

    if(payload = "on", St := 1, St := 0);
end
```

Switch 2 Switch Read and write

Potential-free open-collector output OUT\_2 — max 100 mA / 300 mW, 24 V AC or 36 V DC

string

Values / States: ON · OFF

Write switch state

```taphome
MQTTPUBLISH("shellies/" + MQTTprefix + "/relay/1/command", if(St, "on", "off"))
```

Listener

```taphome
if RECEIVEDMSG.TOPIC = "shellies/" + MQTTprefix + "/relay/1"
    VAR payload := TOSTRING(RECEIVEDMSG.PAYLOAD);

    if(payload = "on", St := 1, St := 0);
end
```

Reed Contact 1 Reed Contact Read-only

Digital input IN\_1 — inverted logic, contact shorted to GND = active (1) in TapHome

string

Listener

```taphome
if RECEIVEDMSG.TOPIC = "shellies/" + MQTTprefix + "/input/0"
    VAR payload := TOSTRING(RECEIVEDMSG.PAYLOAD);

    Rc := if(payload = "0", 1, 0);
end
```

Reed Contact 2 Reed Contact Read-only

Digital input IN\_2 — inverted logic, contact shorted to GND = active (1) in TapHome

string

Listener

```taphome
if RECEIVEDMSG.TOPIC = "shellies/" + MQTTprefix + "/input/1"
    VAR payload := TOSTRING(RECEIVEDMSG.PAYLOAD);

    Rc := if(payload = "0", 1, 0);
end
```

**Connection:** Packet Parser → MQTT • Hostname: `shellyuni-{shelly-id}.local`

Possible improvements (8)

- External Temperature Sensor 1 (DS18B20) — Hardware supports up to 3× DS18B20 on the one-wire bus (Blue DATA + Yellow VCC + Green GND). Not wired in this MQTT template; would need a PacketParserVariable listening on ext\_temperature/0 (value 999 = invalid).
- External Temperature Sensor 2 (DS18B20) — Second DS18B20 on the one-wire bus. Same pattern as sensor 1, different index.
- External Temperature Sensor 3 (DS18B20) — Third DS18B20 on the one-wire bus. Same pattern as sensor 1, different index.
- External Humidity Sensor (DHT22) — Hardware supports 1× DHT22 humidity/temperature sensor (mutually exclusive with DS18B20 chain). Not wired in this MQTT template; would need a PacketParserVariable on ext\_humidity/0 (value 999 = invalid).
- Connection Status (LWT) — Last-Will-Testament topic — 'true' on connect, 'false' on disconnect. Could be added to detect offline devices.
- Input 1 Event — JSON payload {event, event\_cnt} — short/long press events on IN\_1, useful for scene triggers.
- Input 2 Event — JSON payload {event, event\_cnt} — short/long press events on IN\_2.
- Full Status JSON — Full /status JSON published periodically (firmware ≥ 1.8.0). Could be parsed for wifi\_sta.rssi, update status, uptime.

## Import parameters

Enter these values when you import the XML.

| Asked in the app       | Default       |
|------------------------|---------------|
| Mqtt Broker IP address | `192.168.0.1` |
| Mqtt Broker port       | `1883`        |
| Device ID              | `XXXXXXXXX`   |

## Sources

- Shelly Gen1 API Reference
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen1/) 2026-03-12
- Home Assistant Shelly Integration
  
  [www.home-assistant.io](https://www.home-assistant.io/integrations/shelly/) 2026-03-12
- Shelly UNI Knowledge Base
  
  [kb.shelly.cloud](https://kb.shelly.cloud/knowledge-base/shelly-uni) 2026-04-16
- Shelly UNI Documentation (shelly.com)
  
  [www.shelly.com](https://www.shelly.com/blogs/documentation/shelly-uni) 2026-04-16
- Shelly UNI User Guide
  
  [shellysa.co.za](https://shellysa.co.za/wp-content/uploads/2021/04/Shelly-UNI-User-Guide.pdf) 2026-04-16
  
  [PDF](https://taphome.com/compatibility/devices/shelly-uni-mqtt/manufacturer/shelly-uni-user-guide.pdf)

Manufacturer documents are © their respective owners. They are provided as published by the manufacturer, for reference only.

## Related Documentation

- [MQTT Integration](https://taphome.com/en/compatibility/mqtt-guide/)
- [Packet Parser (HTTP, TCP, UDP, FTP, MQTT)](https://taphome.com/en/docs/integration/packet-parser/)
- [Packet parser functions](https://taphome.com/en/docs/script/packet-parser/)
- [Parsing functions](https://taphome.com/en/docs/script/parsing-functions/)
- [MQTT Broker](https://taphome.com/en/docs/integration/packet-parser/mqtt-broker/)
- [Listener scripts](https://taphome.com/en/docs/script/listener-scripts/)