title: "Shelly TRV"
description: "Control room setpoint (5-30 °C) or valve position (0-100 %) on a battery-powered Wi-Fi TRV via HTTP. TapHome integration template for Shelly TRV."
url: "https://taphome.com/en/compatibility/shelly-trv/"
language: en
lastmod: 2026-04-18
generator: hugo
ai:
  topics: ["http","thermostat","wifi","battery-powered","radiator-valve","mdns"]
  questions: ["How to integrate Shelly TRV with TapHome?","What is the difference between the Shelly TRV thermostat and valve templates?","How to calibrate Shelly TRV after mounting on a radiator?","Why does Shelly TRV reject setpoint writes from TapHome?","Why does the Shelly TRV room temperature read too high?","How to disable the weekly schedule so TapHome controls the setpoint?"]
---

# Shelly TRV

Communication: Packet Parser → HTTP

- [Shelly TRV Knowledge Base](https://kb.shelly.cloud/knowledge-base/shelly-trv)
- [Shelly Gen1 API Documentation](https://shelly-api-docs.shelly.cloud/gen1/#shelly-trv)

> Network address
> 
> TapHome reaches this device at the address entered on import. Give the device a fixed address — an IP reservation in the router, or its mDNS name if it supports one — otherwise the integration stops working when the router changes the address.
> 
> [Network Preparation](https://taphome.com/en/docs/setup/network-preparation/)

## Integration guide

The Shelly TRV (SHTRV-01) is a battery-powered Wi-Fi thermostatic radiator valve from Allterco Robotics. It mounts directly on a standard hot-water radiator valve body and regulates room temperature by driving the valve pin via an internal motor. TapHome communicates with the device over HTTP on the local network — no bridge, no cloud, no MQTT broker required.

Shelly TRV is **discontinued** and has been succeeded by the Bluetooth-based [Shelly BLU TRV](https://www.shelly.com/products/shelly-blu-trv). Existing units keep working and this template remains fully supported; for new projects consider the successor.

Two alternative templates are provided for the same physical device — choose one based on the intended control pattern.

| Template | Exposes | Use case |
|----------|---------|----------|
| **Shelly TRV** (main) | Battery + closed-loop thermostat | End-user room temperature control via setpoint (5-30 °C). Firmware drives the valve internally. |
| **Shelly TRV (valve)** | Battery + valve dimmer + thermostat (setpoint variant) | Smart rules that need direct valve override — expose valve position as a 0.0-1.0 dimmer. |

> [!WARNING]
> Do not import both templates for the same physical device. Both bind to the same endpoint and poll loops will collide — writes will conflict and valve behaviour becomes unpredictable.

## Hardware installation

The Shelly TRV has **no wiring** — it is a mechanical radiator head with internal electronics, powered by an internal Li-ion battery (Panasonic NCR18650BD, 3.7 V / 6500 mAh). It mounts directly on the radiator valve body via a metal retaining ring.

### Compatible valve bodies

Native thread: **M30 × 1.5**. The following adapters are included in the retail box:

- **Danfoss** — RA, RAV, RAVL
- **Caleffi**
- **Giacomini**
- **M28 × 1.5** — Sam, Slovarm, Comap, TA, Herz, MMA, Remagg
- **Pont à Mousson**

Third-party adapters (not included) extend compatibility to Gampper, Ista, Meges, Ondal, Oventrop, Rossweiner, Vaillant and others.

### Mounting procedure

1. Ensure the radiator is turned off and cooled down.
2. Turn the existing manual valve head counter-clockwise until fully open, then unscrew the metal retaining ring to remove it.
3. Fit the correct adapter if the valve thread is not native M30 × 1.5.
4. Seat the Shelly TRV on the valve body and tighten the metal ring clockwise — firmly but not over-tightened. Too loose or too tight both cause calibration to fail.
5. Rotate the display to the desired orientation before fully tightening the ring.
6. Briefly press **Reset** (back of device). The display shows `CL` (calibrating) and the internal motor moves in both directions. Successful calibration ends with `AP` on the display; failure shows `E1`.

> [!NOTE]
> Calibration must be performed after every remount on a different valve body. Until `calibrated=true`, TapHome setpoint and position writes are rejected with `Device is not calibrated`.

### Charging

The device charges over **USB-C** (cable supplied, adapter not). A ≥1 A USB-C compliant charger brings the battery from empty to full in approximately 5 hours. Typical battery life is ~2 years (~5 months of a continuous heating season under typical use).

> [!WARNING]
> During charging the body of the device warms up and the internal temperature sensor reads incorrectly. Expect skewed room-temperature values while `charger` is not `disconnected`.

## Configuration

### TapHome import

During template import TapHome asks for a single parameter:

| Parameter | Description | Default |
|-----------|-------------|---------|
| `IpAddress` | Local IP address or mDNS hostname of the device | `192.168.0.1` |

Port `80` is fixed. HTTPS is not supported on Gen1. HTTP Basic Auth must be **disabled** on the device — TapHome does not authenticate HTTP requests to Gen1 Shelly devices.

Use the mDNS hostname (`shellytrv-XXXXXX.local`) where possible — it is resilient to DHCP lease changes. The TapHome **IP Scanner** (Settings → Network → Scan) discovers both the IP and the mDNS hostname.

### Disable the weekly schedule

Shelly TRV has a built-in weekly scheduler (5 profiles, up to 18 scheduled changes per week per profile). When the schedule is enabled, the firmware overwrites any externally-written setpoint at the next scheduled event — TapHome setpoints are silently reverted.

The template surfaces this as a warning (`Schedule is enabled`). Before putting the device under TapHome control, either:

- trigger the **Disable schedule** service action on the module (sends `/settings/thermostats/0?schedule=false`), or
- select the **Disable** profile in the Shelly Cloud app or device Web UI.

### External room sensor (recommended)

The built-in temperature sensor is physically close to the hot radiator pipe and typically reads **1-3 °C higher than the actual room temperature**. Two correction paths are available:

- **External sensor** — pair a separate Wi-Fi thermometer (such as **Shelly H&T**) via the device Web UI → **Sensor Settings** → **Enable external temperature corrections endpoint**. The external sensor then POSTs the ambient temperature to the TRV.
- **Static offset** — use the **Set temperature offset** service action on the Thermostat device (range ±20 °C) to compensate for a constant bias.

For best thermal comfort combine a reliable external sensor with a small static offset as fallback.

## Device capabilities

The main template exposes the device as a battery indicator plus a closed-loop thermostat. The valve template keeps the same module and battery, but exposes valve position as a dimmer and uses a setpoint variant that disables automatic PID control when written. Module-level diagnostics and actions are identical for both templates.

### Battery status

The battery is exposed as a **multi-value switch** derived from the reported charge level and USB-C charger state. The charger state takes precedence over the level:

| State | Condition |
|-------|-----------|
| Critical | `bat.value < 25` |
| Low | `bat.value 25-50` |
| Normal | `bat.value 50-75` |
| Full | `bat.value > 75` |
| Charging | `charger != disconnected` |

Two supplementary service attributes report the raw battery charge (`%`) and cell voltage (V, nominal ~3.7 V, typical range 2.6-4.2 V). The template raises `Low battery` at <50 % and `Battery charge is critically low` at <25 %.

### Thermostat (main template)

A closed-loop room thermostat: TapHome writes the target setpoint, the TRV firmware drives valve position internally based on its built-in (or external) temperature sensor.

- **Read:** measured room temperature (`thermostats[0].tmp.value`) and active target (`thermostats[0].target_t.value`)
- **Write:** setpoint 5-30 °C via `/settings/thermostats/0?target_t={Se}`

Supplementary thermostat attributes include **Temperature offset [°C]**, **Valve position [%]** (read-only, for visibility into the PID output), **Force close**, **Extra pressure** and **Automatic calibration correction**. Corresponding service actions let TapHome set the offset, toggle the force-close mode (valve stays fully closed regardless of setpoint) and toggle extra-pressure mode (boosts actuation for stiff valves).

Setpoint writes fail with `Device is not calibrated` while `calibrated=false`, and the template adds a warning when the weekly schedule is enabled (since the firmware will overwrite external writes on the next schedule event).

### Valve dimmer (valve template)

An alternative template exposes the valve actuator directly as a dimmer device (0.0-1.0 → 0-100 %). TapHome writes position via `/thermostats/0?pos={Le*100}` — the firmware moves the motor to the requested position and implicitly disables automatic target-temperature control.

The valve template adds `Force close`, `Extra pressure` and `Automatic calibration correction` service attributes (plus the matching toggle actions) on the valve device, so that smart-rule authors can drive the motor directly for scenarios such as emergency close, manual pre-heating or boost sequences.

### Thermostat (valve template variant)

The valve template still exposes a thermostat device so that setpoint can be written from the same TapHome device group, but its write script sends **both** `target_t` and `target_t_enabled=false` so that firmware PID does not fight a manually-driven valve. Service attribute set is reduced to **Temperature offset [°C]** (valve-body attributes such as `force_close` and `valve_state` migrate to the valve device instead). The template warns when `target_t.enabled=true` is observed — that indicates a conflict between the valve dimmer and automatic control.

### Module diagnostics and actions

The module (head unit) polls `/status` and `/settings` every 3 seconds and exposes device-wide diagnostics and actions:

- **Diagnostics:** Wi-Fi SSID, IP address, MAC, received signal strength (RSSI in dBm), calibration state, schedule on/off, display brightness (1-7) and display flipped state.
- **Actions:** Disable schedule, Reboot, Calibrate (triggers `/calibrate`), Update firmware (pulls `SHTRV-01_build.gbl` from the official Shelly EU firmware server), Set display brightness and Flip display.

### Additional capabilities

The device also exposes — but the current templates do not yet surface — several Gen1 features: passive open-window detection (`/window`), the symmetrical **Force open** action, fallback ambient temperature (`auto_temp`), child lock, window-open auto-close delay, scheduled-setpoint sensor (`schedule_t`), active-profile index, remaining boost minutes and the **Trigger boost** action (`/thermostats/0?boost_minutes=N`), internal electronics thermal state (`tmp_state`), and firmware-update availability as a sensor. CoIoT push and MQTT transport are both supported at device level but not used — TapHome pulls `/status` every 3 s instead. These can be added in a future template update.

## Troubleshooting

### Device is not calibrated

Every setpoint and valve-position write returns `Device is not calibrated` until the TRV completes a successful calibration cycle.

1. Make sure the device is firmly seated on the valve body — the retaining ring must be tight enough for the motor to load against the valve pin, but not so tight that it deforms.
2. Trigger the **Calibrate** service action on the module (sends `/calibrate`). The display briefly shows `CL` while the motor moves in both directions.
3. On success `calibrated` becomes `true` and writes succeed; failure shows `E1` on the display — usually indicates an incorrect mount.

### Setpoint gets reverted every few hours

This is the weekly schedule overwriting external writes. Check **Schedule** service attribute — if on, trigger the **Disable schedule** action on the module, or disable the active profile in the Shelly Cloud app.

### Room temperature reads too high

Two common causes:

- **Charger connected.** Room-temperature readings are invalid while `charger != disconnected`. Unplug USB-C and allow the device to cool down.
- **Built-in sensor bias.** The sensor sits close to hot pipes and typically reads 1-3 °C high. Either enable the external temperature corrections endpoint and pair a Shelly H&T (or compatible Wi-Fi thermometer) in the same room, or apply a static **Set temperature offset** (e.g. `-1.5 °C`).

### Display shows E1 / E2

`E1` — calibration problem. Remount the device, tighten the ring carefully and trigger a new calibration cycle.

`E2` — temperature sensor problem. `tmp.is_valid` becomes `false` in `/status` and the template adds a `Temperature sensor error` error. If the issue persists after a reboot, the sensor has likely failed — contact Shelly support.

### Device unreachable

1. Verify the TRV is connected to Wi-Fi — press **Up + Down** for 5 s and scroll through the status parameters; `CO` indicates a connected Wi-Fi client.
2. Confirm TapHome CCU and TRV are on the same network / VLAN — Shelly Gen1 does not route across subnets by default.
3. Try the mDNS hostname (`shellytrv-XXXXXX.local`) instead of the IP — the DHCP lease may have changed.
4. Open `http://{device-ip}/status` in a browser. If the JSON response arrives, the device is reachable and the problem is in TapHome configuration.

> [!WARNING]
> Gen1 Shelly devices accept only **2 concurrent HTTP connections**. If TapHome and another system (Home Assistant, Node-RED) poll the same device at the same time, communication becomes unreliable. Keep poll interval at the template default (3 s) and avoid additional pollers.

> [!NOTE]
> Enabling MQTT on Gen1 Shelly devices **irreversibly disables Shelly Cloud**. TapHome uses HTTP only — leave MQTT off unless you explicitly want to migrate away from Shelly Cloud.

## How to install in TapHome

### Prerequisites

- Shelly device installed and powered on
- Local Wi-Fi network (2.4 GHz)
- TapHome CCU on the same network

### Step 1 — Connect Shelly to Wi-Fi

**Option A — Shelly app (recommended):**

1. Download the [Shelly app](https://www.shelly.com/en/support/shelly-app) (iOS / Android)
2. Tap **+** → **Add Device** and follow the Bluetooth pairing wizard
3. Enter your Wi-Fi credentials when prompted

**Option B — AP mode (no app):**

1. On first power-up the device creates a hotspot: `ShellyXXX-AABBCCDDEE`
2. Connect your phone/PC to that hotspot
3. Open `http://192.168.33.1` → **Internet & Security** → **Wi-Fi Mode - Client**
4. Enter SSID and password → **Save**

> [!NOTE]
> Shelly only supports **2.4 GHz** networks. 5 GHz networks will not appear in the scan.

### Step 2 — Find the device address

Shelly Gen1 devices support **mDNS** (Zeroconf). You can reach the device using a hostname instead of an IP address:

```
shelly<model>-<MAC>.local
```

For example: `shelly1pm-AABBCCDDEE.local` (MAC address in uppercase hex, no colons).

> [!TIP]
> **Recommended: use the TapHome IP Scanner.** Open the TapHome app and use the **IP Scanner** (Settings → Network → Scan). The scanner will discover devices on your network and show both the IP address and the mDNS hostname. Use the **hostname** instead of the IP address for a more reliable connection — it stays the same even if the device's IP changes after a router reboot.

**Alternative methods** to find the IP address:

- **Shelly app:** Device detail → **Device info** → IP address
- **Shelly web UI:** Connect to the device AP before Wi-Fi setup — the IP is shown after saving
- **Router DHCP table:** Look for a hostname like `shelly1pm-AABBCCDDEE`

### Step 3 — Configure in TapHome

1. In TapHome, add a new **Packet Parser (HTTP)** module
2. **Address:** enter the mDNS hostname (e.g., `shelly1pm-AABBCCDDEE.local`) or IP address from Step 2
3. **Port:** `80` (default, no change needed)
4. Import the template — TapHome will poll `/status` to read device state

> [!NOTE]
> HTTP authentication is disabled by default on Shelly devices. If you have enabled login protection, TapHome does not support HTTP Basic Auth at this time — keep auth disabled for TapHome integration.

## Available devices 2

These devices appear in TapHome after import.

Shelly TRV Module

Service Attributes

|                          |                                                                                                                               |
|--------------------------|-------------------------------------------------------------------------------------------------------------------------------|
| WiFi SSID                |                                                                                                                               |
| IP address               |                                                                                                                               |
| MAC address              |                                                                                                                               |
| Received signal strength | Wi-Fi signal strength in dBm — typical good range -55 to -70 dBm, below -80 dBm is unreliable                                 |
| Calibrated               | Whether valve mechanical calibration is complete — setpoint and valve-position writes are rejected until calibration succeeds |
| Schedule                 | Weekly schedule on/off — when on, the firmware overwrites externally-written setpoints on the next schedule event             |
| Display brightness       | LED display brightness level (1 = dim, 7 = bright)                                                                            |
| Display flipped          | Whether the LED display is rotated 180° for upside-down mounting                                                              |

Service Actions

|                        |                                                                                                         |
|------------------------|---------------------------------------------------------------------------------------------------------|
| Disable schedule       | Disables the weekly schedule so external setpoints are not reverted at the next schedule event          |
| Reboot                 |                                                                                                         |
| Calibrate              | Starts the mechanical valve calibration cycle — mandatory after every remount on a different valve body |
| Update firmware        | Triggers OTA firmware update from the official Shelly EU firmware server                                |
| Set display brightness | Sets the LED display brightness (1 = dim, 7 = bright)                                                   |
| Flip display           | Toggles the 180° display rotation for upside-down valve orientations                                    |

Custom Variables

Read (module)

```taphome
VAR response := SENDHTTPREQUEST("/status");
IF response.IsSuccess
    status := response.Content;
END

response := SENDHTTPREQUEST("/settings");
IF response.IsSuccess
    settings := response.Content;
END

if(PARSEJSON(status, "$.thermostats[0].schedule"), adderror("Schedule is enabled"));
if(PARSEJSON(status, "$.update.has_update"), addwarning("Firmware update is available"));

var bat := PARSEJSON(status, "$.bat.value");
if bat < 25
    addwarning("Battery charge is criticaly low");
elseif bat < 50
    addwarning("Low battery");
end
```

Service Attributes

Wifi

```taphome
PARSEJSON(status, "$.wifi_sta.ssid")
```

${ipAddress}

```taphome
PARSEJSON(status, "$.wifi_sta.ip")
```

MAC

```taphome
PARSEJSON(status, "$.mac")
```

Received signal strength

```taphome
PARSEJSON(status, "$.wifi_sta.rssi")
```

Calibrated

```taphome
if(PARSEJSON(status, "$.calibrated"), "${detail_deviceSettings_true}", "${detail_deviceSettings_false}")
```

Schedule

```taphome
 VAR response := SENDHTTPREQUEST("/thermostats/0");
IF response.IsSuccess
 VAR content := response.Content;
 VAR responseHeaders := response.Headers;
 RETURN(SWITCH(PARSEJSON(content, "$.schedule"), true, "On", "Off"));
END
```

Display brightness

```taphome
PARSEJSON(settings, "$.display.brightness")
```

Display flipped

```taphome
if(PARSEJSON(settings, "$.display.flipped"), "${detail_deviceSettings_true}", "${detail_deviceSettings_false}")
```

Service Actions

Disable schedule

```taphome
var response := SENDHTTPREQUEST("/settings/thermostats/0?schedule=false");
if(response.IsSuccess, return("OK"), return(response.Content));
```

Reboot

```taphome
VAR response := SENDHTTPREQUEST("/reboot");
if(response.IsSuccess, return("OK"), return(response.Content));
```

Calibrate

```taphome
VAR response := SENDHTTPREQUEST("/calibrate");
if(response.IsSuccess, return("OK"), return(response.Content));
```

Update firmware

```taphome
VAR response := SENDHTTPREQUEST("/ota?url=http://shelly-api-eu.shelly.cloud/firmware/SHTRV-01_build.gbl");
if(response.IsSuccess, return("OK"), return(response.Content));
```

Set display brightness

Parameters: Brightness (1-7) (1–7 Br)

```taphome
var response := SENDHTTPREQUEST("/settings?display_brightness=" + Br);
if(response.IsSuccess, return("OK"), return(response.Content));
```

Flip display

```taphome
var response := SENDHTTPREQUEST("/settings?display_flipped=" + if(PARSEJSON(settings, "$.display.flipped"), "false", "true"));
if(response.IsSuccess, return("OK"), return(response.Content));
```

Battery Multi-value Switch Read-only

Battery charge level as a multi-value switch — Critical (&lt;25%), Low (25-50%), Normal (50-75%), Full (&gt;75%), Charging (USB-C connected). Charging state takes precedence over level

numeric Unit: % multi-value switch

Values / States: Critical · Low · Normal · Full · Charging

Read switch state

```taphome
if PARSEJSON(status, "$.charger")
    return(4);
end

var bat := PARSEJSON(status, "$.bat.value");
if bat > 75
    return(3);
elseif bat > 50
    return(2);
elseif bat > 25
    return(1);
else
    return(0);
end
```

Service Attributes

Value \[%]

```taphome
PARSEJSON(status, "$.bat.value");
```

Voltage \[V]

```taphome
PARSEJSON(status, "$.bat.voltage");
```

Thermostat Thermostat Read and write

Closed-loop room thermostat — write target temperature (5-30 °C), firmware drives the valve internally using the built-in or external sensor

numeric Unit: °C

Service Attributes

|                                  |                                                                                                                         |
|----------------------------------|-------------------------------------------------------------------------------------------------------------------------|
| Temperature offset \[°C]         | Static offset added to measured room temperature — useful when the built-in sensor reads high due to hot-pipe proximity |
| Valve position \[%]              | Current valve opening in percent (0 = fully closed, 100 = fully open)                                                   |
| Force close                      | Whether the valve is forced fully closed regardless of the setpoint                                                     |
| Extra pressure                   | Whether extra-pressure mode is active — applies additional mechanical force to actuate stiff valves                     |
| Automatic calibration correction | Whether fine-tune calibration correction is applied to the mechanical stroke                                            |

Service Actions

|                        |                                                                                                |
|------------------------|------------------------------------------------------------------------------------------------|
| Set temperature offset | Sets the sensor temperature offset (-20 to +20 °C) to compensate for built-in sensor warm bias |
| Toggle force close     | Toggles force-close mode — valve stays fully closed regardless of the setpoint                 |
| Toggle extra pressure  | Toggles extra-pressure mode — boosts valve actuation for stiff valves                          |

Read temperature

```taphome
PARSEJSON(status, "$.thermostats[0].tmp.value")
```

Read (module)

```taphome
if(! PARSEJSON(status, "$.thermostats[0].tmp.is_valid"), adderror("Temperature sensor error"));
```

Read desired temperature

```taphome
PARSEJSON(status, "$.thermostats[0].target_t.value")
```

Write desired temperature

```taphome
if(status = "0", return(Se));

if !PARSEJSON(status, "$.calibrated")
    ADDERROR("Device is not calibrated");
    return(NaN);
end

VAR response := SENDHTTPREQUEST("/settings/thermostats/0?target_t=" + Se);
IF response.IsSuccess = false
  ADDERROR(response.StatusCode);
END
```

Service Attributes

Temperature offset \[°C]

```taphome
PARSEJSON(settings, "$.thermostats[0].temperature_offset")
```

${device\_variable\_valvestate} \[%]

```taphome
PARSEJSON(status, "$.thermostats[0].pos")
```

Force close

```taphome
if(PARSEJSON(settings, "$.thermostats[0].force_close"), "${detail_deviceSettings_true}", "${detail_deviceSettings_false}")
```

Extra pressure

```taphome
if(PARSEJSON(settings, "$.thermostats[0].extra_pressure"), "${detail_deviceSettings_true}", "${detail_deviceSettings_false}")
```

Automatic calibration correction

```taphome
if(PARSEJSON(settings, "$.thermostats[0].calibration_correction"), "${detail_deviceSettings_true}", "${detail_deviceSettings_false}")
```

Service Actions

Set temperature offset

Parameters: Offset (-20–20 C)

```taphome
VAR response := SENDHTTPREQUEST("/settings/thermostats/0?temperature_offset=" + C);
if(response.IsSuccess, return("OK"), return(response.Content));
```

Toggle force close

```taphome
var response := SENDHTTPREQUEST("/settings/thermostats/0?force_close=" + if(PARSEJSON(settings, "$.thermostats[0].force_close"), "false", "true"));
if(response.IsSuccess, return("OK"), return(response.Content));
```

Toggle extra pressure

```taphome
var response := SENDHTTPREQUEST("/settings/thermostats/0?extra_pressure=" + if(PARSEJSON(settings, "$.thermostats[0].extra_pressure"), "false", "true"));
if(response.IsSuccess, return("OK"), return(response.Content));
```

**Connection:** Packet Parser → HTTP • Hostname: `shellytrv-{MAC}.local`

Possible improvements (14)

- Active schedule profile — Currently active profile index (0-4) when scheduling is enabled. Could be added as a multi-value indicator
- Scheduled setpoint — Setpoint that the firmware would apply on the next schedule event
- Boost remaining — Remaining boost time in minutes; pairs with /thermostats/0?boost\_minutes=N write
- Trigger boost — Temporary heating boost action — not currently exposed as service action
- Internal thermal state — Electronics thermal state (Normal / High / Very High); early warning for overheating
- Firmware update availability — Currently surfaced only as warning in module readscript — could be a service attribute
- Open window detection — Passive open-window detection based on temperature drop; publishes 'state: open|closed' and MQTT topic shellies/{id}/window
- Force open — Forces valve 100% open — symmetrical counterpart to force\_close which IS implemented
- Window-open auto-close delay — Delay (1-3600 s) before closing the valve after open-window detection
- Fallback ambient temperature — Fallback setpoint (0-27 °C, 0 = disabled) used when no active setpoint exists
- Child lock — Locks the physical Up/Down buttons on the device
- Schedule rules configuration — Up to 18 rules/profile, 5 named profiles. Complex config — usually managed via Shelly Cloud app
- CoIoT push updates — Optional multicast push (CoAP) — TapHome uses pull polling, not required
- MQTT control — Gen1 MQTT alternative transport — enabling MQTT irreversibly disables Shelly Cloud

## Import parameters

Enter these values when you import the XML.

| Asked in the app | Default       |
|------------------|---------------|
| IP address       | `192.168.0.1` |

## Sources

- Shelly Gen1 API Reference
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen1/) 2026-03-12
- Home Assistant Shelly Integration
  
  [www.home-assistant.io](https://www.home-assistant.io/integrations/shelly/) 2026-03-12
- Shelly TRV — HTTP API (TRV-specific endpoints)
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen1/#shelly-trv) 2026-04-16
- Shelly TRV — Knowledge Base
  
  [kb.shelly.cloud](https://kb.shelly.cloud/knowledge-base/shelly-trv) 2026-04-16
- Shelly TRV — Multilingual User & Safety Guide
  
  [kb.shelly.cloud](https://kb.shelly.cloud/knowledge-base/shelly-trv) 2026-04-16
  
  [PDF](https://taphome.com/compatibility/devices/shelly-trv/manufacturer/user-guide.pdf)
- Peyanski — Home Assistant and Shelly TRV
  
  [peyanski.com](https://peyanski.com/home-assistant-and-shelly-trv/) 2026-04-16

Manufacturer documents are © their respective owners. They are provided as published by the manufacturer, for reference only.

## Related Documentation

- [Packet Parser Integration](https://taphome.com/en/compatibility/packet-parser-guide/)
- [Packet Parser (HTTP, TCP, UDP, FTP, MQTT)](https://taphome.com/en/docs/integration/packet-parser/)
- [Packet parser functions](https://taphome.com/en/docs/script/packet-parser/)