title: "Shelly EM"
description: "Per-channel power (kW), energy (kWh), voltage, reactive power and contactor relay control via HTTP or MQTT. TapHome template for Shelly EM Gen1."
url: "https://taphome.com/en/compatibility/shelly-em/"
language: en
lastmod: 2026-03-29
generator: hugo
ai:
  topics: ["http","mqtt","electric-meter","wifi","energy-metering","contactor-control","ct-clamp"]
  questions: ["How to integrate Shelly EM with TapHome?","What does the Shelly EM TapHome template measure?","How to connect Shelly EM via HTTP to TapHome?","How to connect Shelly EM via MQTT to TapHome?","Can Shelly EM monitor solar export energy?","How to control a contactor with Shelly EM in TapHome?"]
---

# Shelly EM

Communication: Packet Parser → HTTP

- [Shelly EM Product Page](https://www.shelly.com/en/products/shop/shelly-em)

> Network address
> 
> TapHome reaches this device at the address entered on import. Give the device a fixed address — an IP reservation in the router, or its mDNS name if it supports one — otherwise the integration stops working when the router changes the address.
> 
> [Network Preparation](https://taphome.com/en/docs/setup/network-preparation/)

## Integration guide

The Shelly EM is a single-phase energy meter with two independent metering channels and a 2A relay output for contactor control. Each channel connects to an external CT (current transformer) clamp — available in 50A and 120A variants — allowing non-invasive monitoring of two separate circuits simultaneously. TapHome integrates with the device locally over Wi-Fi using either the HTTP REST API or MQTT. No cloud connection is required.

Two TapHome templates are available: an **HTTP template** that polls the device's REST endpoints, and an **MQTT template** that receives data via an MQTT broker. Both expose the same three devices — two energy meters (one per channel) and a contactor switch.

## Configuration

### HTTP template

The HTTP template requires only the device's IP address (or mDNS hostname). TapHome polls three endpoints every 15 seconds:

- `/emeter/0/` — channel 1 energy data
- `/emeter/1/` — channel 2 energy data
- `settings/relay/0` — relay state and schedule check

The module-level read script caches each response into a custom variable (`emeterZero`, `emeterOne`, `status`) so that individual device scripts can parse the data without making redundant HTTP calls.

> [!NOTE]
> The template also checks the relay schedule status from `settings/relay/0`. If internal scheduling is enabled on the Shelly device, the template raises an error — disable scheduling in the Shelly web UI to avoid conflicts with TapHome automation.

### MQTT template

The MQTT template requires the broker IP, port, and the Shelly **Device ID** (format: `shellyem-XXXXXXXXXXXX`, where X = MAC hex digits). The Device ID can be found in the Shelly web UI under **Settings** > **Device Info**.

After enabling MQTT on the Shelly EM (Internet & Security > Advanced — MQTT), TapHome subscribes to `shellies/shellyem-{deviceID}/` topics and receives data via listener scripts.

> [!WARNING]
> On Gen1 Shelly devices, enabling MQTT **disables Shelly Cloud**. Both cannot run simultaneously.

## Device capabilities

### Energy metering (per channel)

Each channel is exposed as an independent Electric Meter device in TapHome, providing:

- **Instantaneous power** — active power in kW (converted from W by dividing by 1000)
- **Cumulative energy** — total consumed energy in kWh (HTTP: converted from Wh; MQTT: uses the persistent `total` topic in Wh)

The HTTP template reads `power` and `total` fields from the `/emeter/{i}/` JSON response. The MQTT template listens to the `emeter/{i}/energy` topic (watt-minutes, divided by 60 000 for kWh) and the `emeter/{i}/total` topic (watt-hours, persistent across reboots).

> [!TIP]
> The MQTT `energy` topic resets to zero on device reboot. For persistent energy tracking, the template also reads the `total` topic which survives reboots.

Each channel also exposes three service attributes:

| Attribute | Unit | Description |
|-----------|------|-------------|
| Voltage | V | RMS line voltage |
| Energy Returned | Wh | Total energy returned to grid — for solar/bidirectional metering |
| Reactive Power | VAR | Instantaneous reactive power |

> [!NOTE]
> The MQTT template exposes only voltage as a service attribute per channel. Reactive power and energy returned are available only in the HTTP template.

### Contactor switch

The relay output is exposed as a switch device in TapHome. The relay is rated **2A / 230 VAC** — it is designed for contactor control only, not for direct load switching.

- **HTTP:** reads `ison` from `settings/relay/0` and controls via `/relay/0?turn=on` or `/relay/0?turn=off`
- **MQTT:** reads from `shellies/shellyem-{id}/relay/0` topic and publishes `on`/`off` to `shellies/shellyem-{id}/relay/0/command`

> [!WARNING]
> The relay is rated only 2A. Always use an external contactor for loads exceeding this rating. Direct connection of high-power loads will damage the relay.

### Additional capabilities

The Shelly EM also exposes power factor (0.00-1.00) and a measurement validity flag per channel, per-channel configuration (CT ratio, max power limit), energy counter reset, auto-off timer on the relay, and WiFi signal strength. Via MQTT, additional topics for real-time power, reactive power, and energy returned per channel are also available. These capabilities can be added in a future template update.

## Troubleshooting

### Device not responding (HTTP)

1. Verify the Shelly EM is connected to Wi-Fi and has a valid IP address
2. Open `http://{device-ip}/shelly` in a browser — if it responds with a JSON containing `"type":"SHEM"`, the device is reachable
3. Check that TapHome CCU and Shelly EM are on the same network / VLAN

### No data on one channel

1. Verify the CT clamp is connected to the correct 3.5mm jack (channel 0 or channel 1)
2. Check that current is flowing through the monitored conductor — the CT clamp must encircle a single conductor, not the entire cable
3. Poll `/emeter/0/` and `/emeter/1/` manually to confirm non-zero `power` values

### MQTT messages not arriving

1. Verify MQTT is enabled in the Shelly web UI (Internet & Security > Advanced — MQTT)
2. Confirm the broker address and port are correct in both the Shelly device and TapHome module settings
3. Check that the `deviceID` custom variable matches the Shelly's Device ID exactly (e.g., `B929CC`)
4. Use an MQTT client (e.g., MQTT Explorer) to subscribe to `shellies/#` and verify the device publishes messages

### Schedule conflict error

The HTTP template checks the `schedule` field in `settings/relay/0`. If the Shelly device has internal scheduling enabled, the template reports an error. Disable scheduling in the Shelly web UI (Settings > Relay > Schedule) — use TapHome automations instead.

> [!WARNING]
> Gen1 Shelly devices support only **2 concurrent HTTP connections**. If TapHome and another system (e.g., Home Assistant) poll the same device simultaneously, communication may become unreliable. Consider switching to the MQTT template for multi-system environments.

## How to install in TapHome

### Prerequisites

- Shelly device installed and powered on
- Local Wi-Fi network (2.4 GHz)
- TapHome CCU on the same network

### Step 1 — Connect Shelly to Wi-Fi

**Option A — Shelly app (recommended):**

1. Download the [Shelly app](https://www.shelly.com/en/support/shelly-app) (iOS / Android)
2. Tap **+** → **Add Device** and follow the Bluetooth pairing wizard
3. Enter your Wi-Fi credentials when prompted

**Option B — AP mode (no app):**

1. On first power-up the device creates a hotspot: `ShellyXXX-AABBCCDDEE`
2. Connect your phone/PC to that hotspot
3. Open `http://192.168.33.1` → **Internet & Security** → **Wi-Fi Mode - Client**
4. Enter SSID and password → **Save**

> [!NOTE]
> Shelly only supports **2.4 GHz** networks. 5 GHz networks will not appear in the scan.

### Step 2 — Find the device address

Shelly Gen1 devices support **mDNS** (Zeroconf). You can reach the device using a hostname instead of an IP address:

```
shelly<model>-<MAC>.local
```

For example: `shelly1pm-AABBCCDDEE.local` (MAC address in uppercase hex, no colons).

> [!TIP]
> **Recommended: use the TapHome IP Scanner.** Open the TapHome app and use the **IP Scanner** (Settings → Network → Scan). The scanner will discover devices on your network and show both the IP address and the mDNS hostname. Use the **hostname** instead of the IP address for a more reliable connection — it stays the same even if the device's IP changes after a router reboot.

**Alternative methods** to find the IP address:

- **Shelly app:** Device detail → **Device info** → IP address
- **Shelly web UI:** Connect to the device AP before Wi-Fi setup — the IP is shown after saving
- **Router DHCP table:** Look for a hostname like `shelly1pm-AABBCCDDEE`

### Step 3 — Configure in TapHome

1. In TapHome, add a new **Packet Parser (HTTP)** module
2. **Address:** enter the mDNS hostname (e.g., `shelly1pm-AABBCCDDEE.local`) or IP address from Step 2
3. **Port:** `80` (default, no change needed)
4. Import the template — TapHome will poll `/status` to read device state

> [!NOTE]
> HTTP authentication is disabled by default on Shelly devices. If you have enabled login protection, TapHome does not support HTTP Basic Auth at this time — keep auth disabled for TapHome integration.

## Available devices 3

These devices appear in TapHome after import.

Shelly EM Module

Custom Variables

Read (module)

```taphome
VAR response := SENDHTTPREQUEST("settings/relay/0");
IF response.IsSuccess
 status := response.Content;
 IF PARSEJSON(status, "schedule")
  ADDERROR("Internal scheduling on");
 END
ELSE
 ADDERROR(response.StatusCode + " (" + response.ReasonPhrase + ")");
 RETURN(NaN);
END
response := SENDHTTPREQUEST("/emeter/0/");
IF response.IsSuccess
 emeterZero := response.Content;
ELSE
 ADDERROR(response.StatusCode + " (" + response.ReasonPhrase + ")");
 RETURN(NaN);
END
response := SENDHTTPREQUEST("/emeter/1/");
IF response.IsSuccess
 emeterOne := response.Content;
ELSE
 ADDERROR(response.StatusCode + " (" + response.ReasonPhrase + ")");
 RETURN(NaN);
END
```

Electric Meter — Channel 1 Electricity Meter Read-only

Instantaneous power (kW) and cumulative energy (kWh) from CT clamp on channel 1

numeric Unit: kW / kWh json\_path

Service Attributes

|                 |                                                                                          |
|-----------------|------------------------------------------------------------------------------------------|
| Voltage         |                                                                                          |
| Energy Returned | Total energy returned to grid on channel 1 — for solar and bidirectional metering setups |
| Reactive Power  |                                                                                          |

Read total consumption

```taphome
RETURN(PARSEJSON(emeterZero, "total")/1000);
```

Read demand

```taphome
RETURN(PARSEJSON(emeterZero, "power")/1000);
```

Service Attributes

Voltage \[V]

```taphome
RETURN(PARSEJSON(emeterZero, "voltage"));
```

backward \[Wh]

```taphome
RETURN(PARSEJSON(emeterZero, "total_returned"));
```

reactive \[W]

```taphome
RETURN(PARSEJSON(emeterZero, "reactive"));
```

Electric Meter — Channel 2 Electricity Meter Read-only

Instantaneous power (kW) and cumulative energy (kWh) from CT clamp on channel 2

numeric Unit: kW / kWh json\_path

Service Attributes

|                 |                                                                                          |
|-----------------|------------------------------------------------------------------------------------------|
| Voltage         |                                                                                          |
| Energy Returned | Total energy returned to grid on channel 2 — for solar and bidirectional metering setups |
| Reactive Power  |                                                                                          |

Read total consumption

```taphome
RETURN(PARSEJSON(emeterOne, "total")/1000);
```

Read demand

```taphome
RETURN(PARSEJSON(emeterOne, "power")/1000);
```

Service Attributes

Voltage \[V]

```taphome
RETURN(PARSEJSON(emeterOne, "voltage"));
```

backward \[Wh]

```taphome
RETURN(PARSEJSON(emeterOne, "total_returned"));
```

reactive \[W]

```taphome
RETURN(PARSEJSON(emeterOne, "reactive"));
```

Contactor Switch Switch Read and write

2A relay output for contactor control — not rated for direct load switching

boolean

Values / States: ON · OFF

Read switch state

```taphome
RETURN(PARSEJSON(status, "ison"));
```

Write switch state

```taphome
# Simple HTTP Request:
# VAR response := SENDHTTPREQUEST("/example/set/value=" + St);
VAR response := SENDHTTPREQUEST("/relay/0?turn="+ if(St = 1, "on","off"));
IF response.IsSuccess = false
 ADDERROR(response.StatusCode);
END
# Set Http request method, body and headers
# VAR response := SENDHTTPREQUEST("/example/setValue", "GET", "value=" + St, "header1:value1", "header2:value2", ...);\r
# Or VAR request := HTTPREQUEST("/example/setValue");
# request.Method := "PUT";
# VAR response := SENDHTTPREQUEST(request);
#r
#
# Send TCP, UDP data:
# VAR data1 := "{\"name\":\"John\", \"age\":" + St + "}";
# SENDDATA(data1);
# VAR data2 := TOBYTES("{\"name\":\"John\", \"age\":" + St + "}", "iso-8859-1");
# SENDDATA(data2);
# You can process received TCP or UDP data in the Listener script
#
#
# Upload data to FTP:
# FTPUPLOAD("filePath", "somedata=" + St, "write"); # use "append" mode to append data to existing file
```

**Connection:** Packet Parser → HTTP • Hostname: `shellyem-{MAC}.local`

Possible improvements (9)

- Power Factor — Power factor (0.00–1.00) per channel, available in /emeter/{i} and /status response. Not available via MQTT.
- Measurement Validity — Boolean flag indicating if the measurement is valid. Available per channel in /emeter/{i}.
- Per-Channel Configuration — CT ratio (ctrafos: 50/120), max\_power limit, appliance\_type. Could be exposed as service actions.
- Reset Energy Counters — Resets accumulated energy data for both channels. Available via HTTP GET and MQTT command topic.
- Auto-off Timer — Auto-off timer in seconds on relay endpoint. Could be added as service action parameter.
- WiFi Signal Strength — WiFi RSSI in dBm, available in /status response
- MQTT Real-time Power — Instantaneous power via MQTT (W). MQTT template uses energy+total topics instead.
- MQTT Reactive Power — Reactive power via MQTT (VAR). HTTP template has it as service attribute, MQTT template does not.
- MQTT Energy Returned — Energy returned to grid via MQTT (Wh). HTTP template has it as service attribute (backward), MQTT template does not.

## Import parameters

Enter these values when you import the XML.

| Asked in the app | Default       |
|------------------|---------------|
| IP address       | `192.168.0.1` |

## Sources

- Shelly Gen1 API Reference
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen1/) 2026-03-12
- Home Assistant Shelly Integration
  
  [www.home-assistant.io](https://www.home-assistant.io/integrations/shelly/) 2026-03-12
- Shelly EM — API Endpoints & MQTT Topics
  
  [shelly-api-docs.shelly.cloud](https://shelly-api-docs.shelly.cloud/gen1/#shelly-em) 2026-03-29
- Shelly EM — Product Specifications
  
  [robomaterial.com](https://robomaterial.com/product/shelly-em-single-phase-energy-meter-with-contactor-control/) 2026-03-29

## Related Documentation

- [Packet Parser Integration](https://taphome.com/en/compatibility/packet-parser-guide/)
- [Packet Parser (HTTP, TCP, UDP, FTP, MQTT)](https://taphome.com/en/docs/integration/packet-parser/)
- [Packet parser functions](https://taphome.com/en/docs/script/packet-parser/)
- [Parsing functions](https://taphome.com/en/docs/script/parsing-functions/)