TapHome works with devices from leading HVAC and smart home manufacturers. Find your manufacturer below to see all available integration templates.
Alfen (2)
+ Request another Alfen deviceAqara (6)
- Aqara Door and Window Sensor Sensor MQTT
- Aqara Motion Sensor (RTCGQ11LM) Sensor MQTT
- Aqara Single Switch Module T1 (With Neutral) Smart plug MQTT
- Aqara Temperature, Humidity and Pressure Sensor Sensor MQTT
- Aqara Vibration Sensor Sensor MQTT
- Aqara Water Leak Sensor Sensor MQTT
Atrea (2)
Atrea DUPLEX ventilation units connect directly via Modbus TCP using the unit's built-in controller — no external gateway needed. Both the older RD5 and newer aMotion controllers are supported, with full operating mode control, fan speed adjustment, bypass management, and an extensive set of diagnostic and alarm registers.
+ Request another Atrea deviceBrink (2)
+ Request another Brink deviceCarlo Gavazzi (2)
+ Request another Carlo Gavazzi deviceComWinTop (3)
- ComWinTop CWT-THxxx Sensor Modbus RTU
- ComWinTop CWT-TM-8PT Sensor Modbus RTU
- ComWinTop CWT-ULS Ultrasonic Level Sensor Sensor Modbus RTU
Daikin (7)
Daikin connects to TapHome via Modbus RTU using manufacturer-supplied adapters that bridge Daikin's internal P1P2 and DIII-NET buses to RS-485. The DCOM-LT/MB serves Altherma 3 heat pumps, the DTA116A51 exposes VRV multi-split systems, and the EKMBPP1 covers Sky Air and VAM/VKM units with Smart Grid support.
- Daikin Altherma 3 DCOM-RW Heat Pump Heat pump Modbus RTU
- Daikin Altherma 3 Heat Pump Heat pump Modbus RTU
- Daikin DTA116A51 VRV Gateway Air conditioning Modbus RTU
- Daikin EKMBPP1 Air conditioning Modbus RTU
- Daikin FWEC3 Air conditioning Modbus RTU
- Daikin RTD-NET FBA-A(9) Air conditioning Modbus RTU
- Daikin RTD-RA Air conditioning Modbus RTU
Delta (2)
+ Request another Delta deviceDomat (3)
- Domat ECIO2 I/O Module Modbus TCP
- Domat R312/R313 I/O Module Modbus RTU
- Domat UC100 Thermostat Thermostat Modbus RTU
Eastron (2)
+ Request another Eastron deviceEBM-Papst (1)
+ Request another EBM-Papst deviceEMS-ESP (2)
- EMS-ESP Gas Boiler (Bosch, Buderus, Junkers, Nefit) Boiler HTTP
- EMS-ESP Heat Pump (Bosch, Buderus, IVT) Heat pump HTTP
Fronius (2)
+ Request another Fronius deviceFujitsu (1)
+ Request another Fujitsu deviceGTD (3)
- GTD IOT 8-Button Touch Switch I/O Module Modbus RTU
- GTD Therm Thermostat Modbus TCP
- GTD8 I/O Module Modbus TCP
Huawei (2)
+ Request another Huawei deviceHusdata (1)
+ Request another Husdata deviceIntesis (20)
- Intesis Air Conditioners Air conditioning Modbus TCP
- Intesis IBOX-MBS-DALI Lighting Modbus RTU
- Intesis IntesisBox Consumption Electric meter Modbus RTU
- Intesis IntesisBOX PA-AW2-MBS-1 Heat pump Modbus TCP
- Intesis IntesisBOX SM-RC-MBS-1 Air conditioning Modbus TCP
- Intesis PA-AW-MBS-1 Heat pump Modbus RTU
- IntesisBOX DK-AC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX DK-RC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX FJ-AC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX FJ-RC-MBS-1 Air conditioning Modbus TCP
- IntesisBox General System Control Gateway Modbus RTU
- IntesisBOX HI-RC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX HS-RC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX LG-RC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX ME-AC-MBS-1 Air conditioning Modbus RTU
- IntesisBOX MH-RC-MBS-1 Air conditioning Modbus TCP
- IntesisBOX PA-RC2-MBS-1 Air conditioning Modbus TCP
- IntesisBOX SM-RC2-MBS-1 Air conditioning Modbus TCP
- IntesisBox Tank Boiler Modbus RTU
- IntesisBOX TO-RC-MBS-1 Air conditioning Modbus TCP
Jablotron (3)
- Jablotron 100 Alarm (JA-121T) Alarm system RS485
- Jablotron Futura Air recovery Modbus TCP
- Jablotron Futura L+ Air recovery Modbus TCP
KEBA (3)
- KEBA KeContact P20 Power Monitoring Wallbox UDP
- KEBA KeContact P20 State Wallbox UDP
- KEBA KeContact P30 Charging Station Wallbox Modbus TCP
Kostal (2)
+ Request another Kostal deviceLG (3)
- LG Air Conditioning (PI-485 / LGAP) Air conditioning RS485
- LG Therma V (pre-2021) Heat pump Modbus RTU
- LG ThermaV (2021+) Heat pump Modbus RTU
NIBE (3)
NIBE heat pumps connect via two Modbus paths: the F1245 ground-source model requires the MODBUS 40 RS-485 accessory, while the SMO S40 controller and VVM S320 indoor module connect directly over Modbus TCP with built-in Ethernet — no additional hardware required. The VVM S320 template is the most comprehensive, combining heat pump control, ERS 1 ventilation management, and energy metering.
- Nibe F1245 Heat pump Modbus RTU
- Nibe SMO S40 Heat Pump Controller Heat pump Modbus TCP
- Nibe VVM S320 Heat pump Modbus TCP
Nilan (2)
Nilan's CTS-602 controller uses Modbus RTU over RS-485, requiring a third-party RS-485-to-Ethernet bridge (such as USR-TCP232 or Waveshare) to reach TapHome via Modbus TCP. The same controller and integration path covers both pure heat-recovery ventilation units and combined heat pump systems, providing ventilation, climate, DHW, and humidity control through a single connection.
+ Request another Nilan deviceOlimpia Splendid (1)
+ Request another Olimpia Splendid deviceOrno (3)
- Orno OR-WE-515 Electric meter Modbus RTU
- Orno OR-WE-517 Electric meter Modbus RTU
- Orno OR-WE-525/526 Electric meter Modbus RTU
Other (2)
+ Request another Other devicePichler (2)
+ Request another Pichler deviceProtoART (1)
+ Request another ProtoART deviceResi (2)
+ Request another Resi deviceSamsung (5)
Samsung integrates through the MIM-B19N Modbus RTU gateway, which bridges Samsung's proprietary R1/R2 (NASA) bus to RS-485. One gateway serves three roles: EHS heat pump control with DHW management, AC indoor unit control (including Wind-Free and 360 cassette modes), and bus-level diagnostics with auto-discovery of up to 48 connected units.
- Samsung MIM-B19N (EHS) Heat pump Modbus RTU
- Samsung MIM-B19N (Gateway) Gateway Modbus RTU
- Samsung MIM-B19N (IU) Air conditioning Modbus RTU
- Samsung WindFree Air Conditioner Air conditioning HTTP
- SmartThings Switch/Plug with Power Metering Smart plug HTTP
Sensibo (1)
+ Request another Sensibo deviceShelly (44)
Shelly devices connect directly over Wi-Fi with no hub or gateway required. Mains-powered devices (relay switches, smart plugs) use the local HTTP API for on/off control and energy metering, while battery-powered sensors push events via MQTT — making Shelly the only brand that uses two different protocols within a single manufacturer integration.
- Shelly 1PM Smart plug MQTT
- Shelly 1PM Electric meter HTTP
- Shelly 1PM Gen3 Electric meter HTTP
- Shelly 2.5 I/O Module HTTP
- Shelly 2PM Gen3 Electric meter HTTP
- Shelly 3EM Electric meter HTTP
- Shelly 3EM Gen3 Electric meter HTTP
- Shelly 3EM MQTT Electric meter MQTT
- Shelly BLU TRV Thermostat HTTP
- Shelly Dimmer 2 Lighting HTTP
- Shelly Door/Window 2 Sensor MQTT
- Shelly DUO Lighting HTTP
- Shelly DUO MQTT Lighting MQTT
- Shelly DUO RGBW Lighting HTTP
- Shelly DUO RGBW MQTT Lighting MQTT
- Shelly EM Electric meter HTTP
- Shelly EM MQTT Electric meter MQTT
- Shelly Flood Sensor MQTT
- Shelly Gas Sensor HTTP
- Shelly Gas MQTT Sensor MQTT
- Shelly H&T Sensor MQTT
- Shelly H&T Gen3 Sensor MQTT
- Shelly i3 I/O Module HTTP
- Shelly Motion 2 Sensor MQTT
- Shelly Plug S Smart plug MQTT
- Shelly Plug S Smart plugElectric meter HTTP
- Shelly Plus 1 I/O Module HTTP
- Shelly Plus 1PM Electric meter MQTT
- Shelly Plus 1PM Electric meter HTTP
- Shelly Plus 2PM Electric meter HTTP
- Shelly Plus H&T Sensor MQTT
- Shelly Plus i4 I/O Module MQTT
- Shelly Plus Plug S Smart plugElectric meter HTTP
- Shelly Plus RGBW PM Lighting HTTP
- Shelly Plus Smoke Sensor MQTT
- Shelly PM Mini Gen3 Electric meter HTTP
- Shelly Pro 3 I/O Module HTTP
- Shelly Pro 3EM Electric meter HTTP
- Shelly Pro 4PM Electric meter HTTP
- Shelly RGBW2 Lighting HTTP
- Shelly RGBW2 White Lighting HTTP
- Shelly Sensor Add-On Sensor HTTP
- Shelly TRV Thermostat HTTP
- Shelly UNI I/O Module MQTT
Sinclair (2)
Sinclair products feature a native Modbus RTU interface built directly into both heat pump and split air conditioning units — no gateway hardware required. A single RS-485 connection covers hydronic heat pump control (heating, DHW, weather compensation) and split AC management (modes, fan, swing, sleep schedules).
- Sinclair Ontario Heat Pump Heat pump Modbus RTU
- Sinclair Uni Split Air Conditioning Air conditioning Modbus RTU
SolaX (4)
- SolaX Hybrid X1/X3 Gen 4 Inverter Modbus RTU
- SolaX Inverter (Cloud API) Inverter HTTP
- SolaX SK-SU Hybrid Inverter Inverter Modbus TCP
- SolaX X3 Hybrid Ultra Inverter Modbus RTU
Sonoff (1)
Requested · 1 interested Sonoff SNZB-02LD in TapHome: a Zigbee temperature probe as a wireless floor sensorBeta + Request another Sonoff deviceStiebel Eltron (2)
- Stiebel Eltron HPA-O Heat Pump Heat pump Modbus TCP
- Stiebel Eltron HPA-O Serie Heat Pump Heat pump Modbus TCP
Victron Energy (1)
+ Request another Victron Energy deviceViessmann (2)
Viessmann heating systems use the proprietary LON bus internally, requiring the Vitogate 300 gateway to bridge to Modbus RTU or TCP for TapHome access. This covers both heat pump and boiler product lines, with support for multi-circuit heating, DHW, solar thermal integration, and weather compensation.
- Viessmann Vitogate 300 + Vitocal 200 Heat pump Modbus RTU
- Viessmann Vitogate 300 + Vitotronic 200 HK3B Boiler Modbus RTU
Wattsonic (2)
- Wattsonic Hybrid Inverter G3 Inverter Modbus RTU
- Wattsonic WTS 3-Phase Hybrid Inverter Inverter Modbus RTU
WellPro (2)
+ Request another WellPro deviceYeelight (2)
+ Request another Yeelight deviceZHONG SHENG (XY) (1)
+ Request another ZHONG SHENG (XY) deviceSign in with your TapHome account to follow. We email you when something changes; unsubscribe in one click.