﻿<?xml version="1.0" encoding="utf-8"?>
<Templates format="2" protocolVersion="88">
  <Template revision="1.0" id="9c641830-526f-446e-bbd4-97c4662304ce">
    <SuggestedCCUParameters>
      <ReconnectDelay>0</ReconnectDelay>
      <AfterConnectDelay>0</AfterConnectDelay>
      <TcpNoDelay>False</TcpNoDelay>
      <TcpPort>502</TcpPort>
      <DelayBetweenRequests>-1</DelayBetweenRequests>
      <ReadWriteTimeout>1000</ReadWriteTimeout>
    </SuggestedCCUParameters>
    <ImportParameters>
      <Parameter>
        <Id>SlaveId</Id>
        <Name>Slave Id</Name>
        <Value>1</Value>
      </Parameter>
      <Parameter>
        <Id>IpAddress</Id>
        <Name>IP address</Name>
        <Value>192.168.1.0</Value>
      </Parameter>
    </ImportParameters>
    <RevisionHistory>
      <Revision id="1.0">Initial version</Revision>
    </RevisionHistory>
    <Name>Temeprature, Humidity, Barometer</Name>
    <CcuModel>ModbusTcpCCU</CcuModel>
    <Producer></Producer>
    <Model></Model>
    <Description></Description>
    <Module>
      <Name>Temeprature, Humidity, Barometer</Name>
      <Id>-1</Id>
      <Model>ModbusModule</Model>
      <DeviceProperties>
        <DeviceType>7001</DeviceType>
        <InternalPollInterval>30000</InternalPollInterval>
        <PrefetchModeId>0</PrefetchModeId>
        <SlaveId>$[SlaveId]</SlaveId>
        <IpAddress>$[IpAddress]</IpAddress>
        <ModuleVariables>[{"Name":"CORBAR","ValueTypeId":1,"NumericValue":17},{"Name":"CORH","ValueTypeId":1,"NumericValue":0.01},{"Name":"CORTE","ValueTypeId":1,"NumericValue":0.5}]</ModuleVariables>
        <MaxPrefetchGroupSize>100</MaxPrefetchGroupSize>
      </DeviceProperties>
      <Devices>
        <Device>
          <Name>B1-BAROMETER</Name>
          <Model>ModbusVariable</Model>
          <Id>-2</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"25":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:25}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>1000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 4, uInt32)/100 + CORBAR</ReadState>
            <WriteState></WriteState>
            <IconId>0</IconId>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>B1-Teplota</Name>
          <Model>ModbusVariable</Model>
          <Id>-3</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"5":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:5}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>5000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 0, uInt16)/10 + CORTE</ReadState>
            <WriteState></WriteState>
            <IconId>0</IconId>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>B1-VLHKOSŤ</Name>
          <Model>ModbusVariable</Model>
          <Id>-4</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"3":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:3}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>5000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 1, uInt16)*0.001 + CORH</ReadState>
            <WriteState></WriteState>
            <IconId>0</IconId>
          </DeviceProperties>
        </Device>
      </Devices>
    </Module>
  </Template>
</Templates>