﻿<?xml version="1.0" encoding="utf-8"?>
<Templates format="2" protocolVersion="83">
  <Template revision="1.0" id="42793c0d-7e41-4e14-b2a2-6419df37f984">
    <SuggestedCCUParameters>
      <UseAsciiCommunication>False</UseAsciiCommunication>
      <StopBits>One</StopBits>
      <DataBits>8</DataBits>
      <Parity>Even</Parity>
      <Baudrate>19200</Baudrate>
      <DelayBetweenRequests>-1</DelayBetweenRequests>
      <ReadWriteTimeout>1500</ReadWriteTimeout>
    </SuggestedCCUParameters>
    <ImportParameters>
      <Parameter>
        <Id>SlaveId</Id>
        <Name>Slave Id</Name>
        <Value>1</Value>
      </Parameter>
      <Parameter>
        <Id>IpAddress</Id>
        <Name>IP address</Name>
        <Value>192.168.1.0</Value>
      </Parameter>
    </ImportParameters>
    <RevisionHistory>
      <Revision id="1.0">Initial version</Revision>
    </RevisionHistory>
    <Name>Siber DF EVO</Name>
    <CcuModel>ModbusRtuCCU</CcuModel>
    <Producer></Producer>
    <Model></Model>
    <Description></Description>
    <Module>
      <Name>Siber DF EVO</Name>
      <Id>-1</Id>
      <Model>ModbusModule</Model>
      <DeviceProperties>
        <DeviceType>7001</DeviceType>
        <InternalPollInterval>30000</InternalPollInterval>
        <ReadScript>switch(modbusr(H, 41003, Uint16),
1, ADDERROR("Nespecifikovana chyba"),
2, ADDWARNING("Nudzove zastavenie"),
3, ADDERROR("Chyba vstupneho ventilatora 1"),
4, ADDERROR("Chyba senzora X22"),
5, ADDERROR("Chyba senzora X23"),
6, ADDERROR("Chyba senzora X21"),
7, ADDERROR("Chyba senzora X20"),
8, ADDERROR("Chyba ventilatora 2"),
254, ADDWARNING("Parovaci rezim je aktivny"),
255, ADDWARNING("Identifikacia zariadenia je aktivna"),
NaN
)</ReadScript>
        <PrefetchModeId>0</PrefetchModeId>
        <SlaveId>$[SlaveId]</SlaveId>
        <MaxPrefetchGroupSize>100</MaxPrefetchGroupSize>
        <IpAddress>$[IpAddress]</IpAddress>
      </DeviceProperties>
      <Devices>
        <Device>
          <Name>Bypass</Name>
          <Model>ModbusAnalogInput</Model>
          <Id>-2</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions />
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadInputLevel>MODBUSR(H, 41016, Uint16) / 100</ReadInputLevel>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Filter</Name>
          <Model>ModbusAnalogInput</Model>
          <Id>-3</Id>
          <DeviceProperties>
            <DeviceType>11003</DeviceType>
            <SerializedValueLogTypeConversions />
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript>if modbusr(H, 41014, Bool)
	ADDWARNING("Filter je spinavy");
end</ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas>[{"AttributeDefinition":{"Name":"Cas do vymeny filtra [dni]"},"ReadFormula":"modbusr(H, 41040, Uint16)"},{"AttributeDefinition":{"Name":"Interval na vymenu filtra [dni]"},"ReadFormula":"modbusr(H, 41041, Uint16)"}]</ServiceAttributesFormulas>
            <ServiceActionsScripts>[{"ActionDefinition":{"Name":"Vymena filtra","NumericParameters":[],"BoolParameters":[],"EnumParameters":[]},"Script":"modbusw(H, 42000, Uint16, 0)"}]</ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadInputLevel>linear(MODBUSR(H, 41042, Uint16) / 100, 0, 1, 1, 0)</ReadInputLevel>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Odmrazovanie</Name>
          <Model>ModbusReedContact</Model>
          <Id>-4</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <OnStateIconId>347</OnStateIconId>
            <OffStateIconId>61</OffStateIconId>
            <OnStateName>${general_open}</OnStateName>
            <OffStateName>${general_closed}</OffStateName>
            <ReadState>MODBUSR(H, 41015, Bool)</ReadState>
            <NegateState>False</NegateState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>${temperature_air}</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-5</Id>
          <DeviceProperties>
            <DeviceType>3001</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 41005, LittleEndianFloat)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Prietok vzduchu - vstup</Name>
          <Model>ModbusVariable</Model>
          <Id>-6</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"98":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:98}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 41019, LittleEndianFloat)</ReadState>
            <WriteState></WriteState>
            <IconId>0</IconId>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Prietok vzduchu - vystup</Name>
          <Model>ModbusVariable</Model>
          <Id>-7</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"98":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:98}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 41021, LittleEndianFloat)</ReadState>
            <WriteState></WriteState>
            <IconId>0</IconId>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Rychlost ventilatora</Name>
          <Model>ModbusMultiValueSwitch</Model>
          <Id>-8</Id>
          <DeviceProperties>
            <DeviceType>6010</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <Value0Index>0</Value0Index>
            <Value1Index>1</Value1Index>
            <Value2Index>2</Value2Index>
            <Value3Index>3</Value3Index>
            <Value4Index>4</Value4Index>
            <Value5Index>5</Value5Index>
            <Value6Index>70</Value6Index>
            <Value7Index>7</Value7Index>
            <Value8Index>72</Value8Index>
            <Value9Index>73</Value9Index>
            <Value0Name>${level_0Of4}</Value0Name>
            <Value1Name>Minimum</Value1Name>
            <Value2Name>1</Value2Name>
            <Value3Name>2</Value3Name>
            <Value4Name>3</Value4Name>
            <Value5Name>Automatika</Value5Name>
            <Value6Name></Value6Name>
            <Value7Name>Boost</Value7Name>
            <Value8Name></Value8Name>
            <Value9Name></Value9Name>
            <Value0IconId>24</Value0IconId>
            <Value1IconId>116</Value1IconId>
            <Value2IconId>21</Value2IconId>
            <Value3IconId>22</Value3IconId>
            <Value4IconId>23</Value4IconId>
            <Value5IconId>117</Value5IconId>
            <Value6IconId>0</Value6IconId>
            <Value7IconId>123</Value7IconId>
            <Value8IconId>0</Value8IconId>
            <Value9IconId>0</Value9IconId>
            <OffStateValue>0</OffStateValue>
            <ReadSwitchState>var read := MODBUSR(H, 41000, Uint16);
switch(read,
1, 2,
2, 3,
3, 4,
11, 1,
12, 2,
13, 3,
21, 1,
23, 7,
24, 5,
0)</ReadSwitchState>
            <WriteSwitchState>MODBUSW(H, 41500, Uint16, Mu)</WriteSwitchState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Rychlost vstupneho ventilatora</Name>
          <Model>ModbusVariable</Model>
          <Id>-9</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"95":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:95}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 41002, Uint16)/200</ReadState>
            <WriteState></WriteState>
            <IconId>28</IconId>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Rychlost vystupneho ventilatora</Name>
          <Model>ModbusVariable</Model>
          <Id>-10</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"95":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:95}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 41001, Uint16)/200</ReadState>
            <WriteState></WriteState>
            <IconId>28</IconId>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>${deviceType_OutdoorTemperature}</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-11</Id>
          <DeviceProperties>
            <DeviceType>3003</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 41007, LittleEndianFloat)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Vstupna teplota</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-12</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 41011, LittleEndianFloat)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Vystupna teplota</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-13</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 41009, LittleEndianFloat)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
      </Devices>
    </Module>
  </Template>