﻿<?xml version="1.0" encoding="utf-8"?>
<Templates format="2" protocolVersion="83">
  <Template revision="1.1" id = "ae06433d-4d7d-43ad-b945-b425dfdc4190">
    <SuggestedCCUParameters />
    <RevisionHistory>
      <Revision id="1.0">Initial version</Revision>
      <Revision id="1.1">Changed to use RECEIVEDMSG</Revision>
    </RevisionHistory>
    <Name>Shelly GAS MQTT</Name>
    <CcuModel>PacketParserCCU</CcuModel>
    <Producer></Producer>
    <Model></Model>
    <Description>To enable MQTT in browser interface go to Internet and Security / Advanced - Developer Settings, tick "Enable action execution via MQTT" and fill out "Server" input by formula {MQTT broker IP address}:{port}" and press SAVE.

To find Device ID in browser interface go to Settings / Device Info / Device ID. It is the first string of characters (not in the brackets!)
</Description>
    <ImportParameters>
      <Parameter>
        <Name>Mqtt Broker ${ipAddress}</Name>	
        <Value>192.168.0.1</Value>
        <Id>IpAddress</Id>
      </Parameter>
      <Parameter>
        <Name>Mqtt Broker port</Name>	
        <Value>1883</Value>
        <Id>Port</Id>
      </Parameter>
      <Parameter>
        <Name>Device ID</Name>	
        <Value></Value>
        <Id>dID</Id>
      </Parameter>
		</ImportParameters>
    <Module>
      <Name>Shelly GAS MQTT</Name>
      <Id>-1</Id>
      <Model>PacketParserModuleMqtt</Model>
      <DeviceProperties>
        <InternalPollInterval>5000</InternalPollInterval>
        <CustomVariables>[{"Name":"deviceID","ValueTypeId":2,"NumericValue":0,"StringValue":"$[dID]"}]</CustomVariables>
        <ServiceActionsScriptsPacketParser>[{"ActionDefinition":{"Name":"Self test","NumericParameters":[],"BoolParameters":[],"EnumParameters":[]},"Script":"mqttpublish(\u0022shellies/shellygas-\u0022\u002BdeviceID\u002B\u0022/sensor/start_self_test\u0022,\u00221\u0022);"}]</ServiceActionsScriptsPacketParser>
        <IpAddress>$[IpAddress]</IpAddress>
        <Port>$[Port]</Port>
        <RootTopic>shellies/#</RootTopic>
      </DeviceProperties>
      <Devices>
        <Device>
          <Name>Gas Alarm</Name>
          <Model>PacketParserMultiValueSwitch</Model>
          <Id>-2</Id>
          <DeviceProperties>
            <ReadScriptPacketParser />
            <InternalPollInterval>2500</InternalPollInterval>
            <CustomVariables>[]</CustomVariables>
            <ServiceAttributesScriptsPacketParser></ServiceAttributesScriptsPacketParser>
            <ServiceActionsScriptsPacketParser></ServiceActionsScriptsPacketParser>
            <ListenerScriptPacketParser># Parse received bytes:
IF(RECEIVEDMSG.TOPIC = "shellies/shellygas-"+deviceID+"/sensor/gas")
 switch(TOSTRING(RECEIVEDMSG.PAYLOAD),
 "none", Mu := 0,
 "mild",Mu := 1,
 "heavy",Mu := 2,
 "test", Mu := 3,
 Mu := 4);
END
</ListenerScriptPacketParser>
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <Value0Index>0</Value0Index>
            <Value1Index>1</Value1Index>
            <Value2Index>2</Value2Index>
            <Value3Index>3</Value3Index>
            <Value4Index>4</Value4Index>
            <Value5Index>69</Value5Index>
            <Value6Index>70</Value6Index>
            <Value7Index>71</Value7Index>
            <Value8Index>72</Value8Index>
            <Value9Index>73</Value9Index>
            <Value0Name>No alarm</Value0Name>
            <Value1Name>Mild gas leak</Value1Name>
            <Value2Name>Heavy gas leak</Value2Name>
            <Value3Name>Self Test</Value3Name>
            <Value4Name>Alarm state is unknown</Value4Name>
            <Value5Name>5</Value5Name>
            <Value6Name>6</Value6Name>
            <Value7Name>7</Value7Name>
            <Value8Name>8</Value8Name>
            <Value9Name>9</Value9Name>
            <Value0IconId>329</Value0IconId>
            <Value1IconId>328</Value1IconId>
            <Value2IconId>327</Value2IconId>
            <Value3IconId>326</Value3IconId>
            <Value4IconId>326</Value4IconId>
            <Value5IconId>10</Value5IconId>
            <Value6IconId>11</Value6IconId>
            <Value7IconId>12</Value7IconId>
            <Value8IconId>13</Value8IconId>
            <Value9IconId>14</Value9IconId>
            <OffStateValue>-1</OffStateValue>
            <ReadSwitchStateScriptPacketParser># Simple HTTP Request:
# VAR response := SENDHTTPREQUEST("/example/getValue");
# IF response.IsSuccess
#  VAR content := response.Content;
#  VAR responseHeaders := response.Headers;
#  RETURN(PARSEXML(content, "//element1/value1"));
# ELSE
#  ADDERROR(response.StatusCode + " (" + response.ReasonPhrase + ")");
#  RETURN(NaN);
# END
#
# Set Http request method, body and headers
# VAR response := SENDHTTPREQUEST("/example/getValue", "GET", "some data", "header1:value1", "header2:value2", ...);
# OR
# VAR request := HTTPREQUEST("/example/getValue", "POST", "some data");
# request.headers := { "header1:value1", "header2:value2", ...};
# request.method := "GET";
# request.data := null;
# VAR response := SENDHTTPREQUEST(request);
#
#
# Send TCP, UDP data:
# VAR data1 := BYTECOLLECTION("0a bb ea df 01");
# SENDDATA(data1);
# VAR data2 := "{\"name\":\"John\", \"age\":32}";
# SENDDATA(data2);
# VAR data3 := TOBYTES("{\"name\":\"John\", \"age\":32}", "iso-8859-1");
# SENDDATA(data3);
# Process received TCP or UDP data and set device values in the Listener script
#
#
# Download data from FTP:
# FTPDOWNLOAD("filePath");</ReadSwitchStateScriptPacketParser>
            <WriteSwitchStateScriptPacketParser># Simple HTTP Request:
# VAR response := SENDHTTPREQUEST("/example/set/value=" + Mu);
# IF response.IsSuccess = false
#  ADDERROR(response.StatusCode);
# END
#
# Set Http request method, body and headers
# VAR response := SENDHTTPREQUEST("/example/setValue", "GET", "value=" + Mu, "header1:value1", "header2:value2", ...);\r
# Or VAR request := HTTPREQUEST("/example/setValue");
# request.Method := "PUT";
# VAR response := SENDHTTPREQUEST(request);
#r
#
# Send TCP, UDP data:
# VAR data1 := "{\"name\":\"John\", \"age\":" + Mu + "}";
# SENDDATA(data1);
# VAR data2 := TOBYTES("{\"name\":\"John\", \"age\":" + Mu + "}", "iso-8859-1");
# SENDDATA(data2);
# You can process received TCP or UDP data in the Listener script
#
#
# Upload data to FTP:
# FTPUPLOAD("filePath", "somedata=" + Mu, "write"); # use "append" mode to append data to existing file</WriteSwitchStateScriptPacketParser>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Gas concentration (parts per milion)</Name>
          <Model>PacketParserVariable</Model>
          <Id>-3</Id>
          <DeviceProperties>
            <SerializedValueLogTypeConversions />
            <ReadScriptPacketParser># Simple HTTP Request:
# VAR response := SENDHTTPREQUEST("/example/getValue");
# IF response.IsSuccess
#  VAR content := response.Content;
#  VAR responseHeaders := response.Headers;
#  RETURN(PARSEXML(content, "//element1/value1"));
# ELSE
#  ADDERROR(response.StatusCode + " (" + response.ReasonPhrase + ")");
#  RETURN(NaN);
# END
#
# Set Http request method, body and headers
# VAR response := SENDHTTPREQUEST("/example/getValue", "GET", "some data", "header1:value1", "header2:value2", ...);
# OR
# VAR request := HTTPREQUEST("/example/getValue", "POST", "some data");
# request.headers := { "header1:value1", "header2:value2", ...};
# request.method := "GET";
# request.data := null;
# VAR response := SENDHTTPREQUEST(request);
#
#
# Send TCP, UDP data:
# VAR data1 := BYTECOLLECTION("0a bb ea df 01");
# SENDDATA(data1);
# VAR data2 := "{\"name\":\"John\", \"age\":32}";
# SENDDATA(data2);
# VAR data3 := TOBYTES("{\"name\":\"John\", \"age\":32}", "iso-8859-1");
# SENDDATA(data3);
# Process received TCP or UDP data and set device values in the Listener script
#
#
# Download data from FTP:
# FTPDOWNLOAD("filePath");</ReadScriptPacketParser>
            <InternalPollInterval>15000</InternalPollInterval>
            <CustomVariables />
            <ServiceAttributesScriptsPacketParser></ServiceAttributesScriptsPacketParser>
            <ServiceActionsScriptsPacketParser></ServiceActionsScriptsPacketParser>
            <ListenerScriptPacketParser># Parse received bytes:
IF(RECEIVEDMSG.TOPIC = "shellies/shellygas-"+deviceID+"/sensor/concentration")
 Va := todouble(TOSTRING(RECEIVEDMSG.PAYLOAD));
END
</ListenerScriptPacketParser>
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>False</IsReadOnly>
            <ReadStateScriptPacketParser />
            <WriteStateScriptPacketParser># Simple HTTP Request:
# VAR response := SENDHTTPREQUEST("/example/set/value=" + Va);
# IF response.IsSuccess = false
#  ADDERROR(response.StatusCode);
# END
#
# Set Http request method, body and headers
# VAR response := SENDHTTPREQUEST("/example/setValue", "GET", "value=" + Va, "header1:value1", "header2:value2", ...);\r
# Or VAR request := HTTPREQUEST("/example/setValue");
# request.Method := "PUT";
# VAR response := SENDHTTPREQUEST(request);
#r
#
# Send TCP, UDP data:
# VAR data1 := "{\"name\":\"John\", \"age\":" + Va + "}";
# SENDDATA(data1);
# VAR data2 := TOBYTES("{\"name\":\"John\", \"age\":" + Va + "}", "iso-8859-1");
# SENDDATA(data2);
# You can process received TCP or UDP data in the Listener script
#
#
# Upload data to FTP:
# FTPUPLOAD("filePath", "somedata=" + Va, "write"); # use "append" mode to append data to existing file</WriteStateScriptPacketParser>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Mute Active Alarm</Name>
          <Model>PacketParserPushButton</Model>
          <Id>-4</Id>
          <DeviceProperties>
            <ReadScriptPacketParser />
            <InternalPollInterval>10000</InternalPollInterval>
            <CustomVariables />
            <ServiceAttributesScriptsPacketParser></ServiceAttributesScriptsPacketParser>
            <ServiceActionsScriptsPacketParser></ServiceActionsScriptsPacketParser>
            <ListenerScriptPacketParser></ListenerScriptPacketParser>
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <WriteButtonPressedStateScriptPacketParser>MQTTPUBLISH("shellies/shellygas-&lt;deviceid&gt;/sensor/mute","1");

# Simple HTTP Request:
# VAR response := SENDHTTPREQUEST("/example/set/value=" + Bp);
# IF response.IsSuccess = false
#  ADDERROR(response.StatusCode);
# END
#
# Set Http request method, body and headers
# VAR response := SENDHTTPREQUEST("/example/setValue", "GET", "value=" + Bp, "header1:value1", "header2:value2", ...);\r
# Or VAR request := HTTPREQUEST("/example/setValue");
# request.Method := "PUT";
# VAR response := SENDHTTPREQUEST(request);
#r
#
# Send TCP, UDP data:
# VAR data1 := "{\"name\":\"John\", \"age\":" + Bp + "}";
# SENDDATA(data1);
# VAR data2 := TOBYTES("{\"name\":\"John\", \"age\":" + Bp + "}", "iso-8859-1");
# SENDDATA(data2);
# You can process received TCP or UDP data in the Listener script
#
#
# Upload data to FTP:
# FTPUPLOAD("filePath", "somedata=" + Bp, "write"); # use "append" mode to append data to existing file</WriteButtonPressedStateScriptPacketParser>
            <IconId>206</IconId>
          </DeviceProperties>
        </Device>
      </Devices>
    </Module>
  </Template>
</Templates>