﻿<?xml version="1.0" encoding="utf-8"?>
<Templates format="2" protocolVersion="76">
  <Template revision="1.0" id="1e8dd5b7-e6f9-4b4c-b63e-04aff449c612">
    <SuggestedCCUParameters>
      <UseAsciiCommunication>False</UseAsciiCommunication>
      <StopBits>One</StopBits>
      <DataBits>8</DataBits>
      <Parity>None</Parity>
      <Baudrate>9600</Baudrate>
      <DelayBetweenRequests>-1</DelayBetweenRequests>
      <ReadWriteTimeout>1000</ReadWriteTimeout>
    </SuggestedCCUParameters>
    <ImportParameters>
      <Parameter>
        <Id>SlaveId</Id>
        <Name>Slave Id</Name>
        <Value>1</Value>
      </Parameter>
      <Parameter>
        <Id>IpAddress</Id>
        <Name>IP address</Name>
        <Value>192.168.1.0</Value>
      </Parameter>
    </ImportParameters>
    <RevisionHistory>
      <Revision id="1.0">Initial version</Revision>
    </RevisionHistory>
    <Name>Midea Heat Pump</Name>
    <CcuModel>ModbusRtuCCU</CcuModel>
    <Producer></Producer>
    <Model></Model>
    <Description></Description>
    <Module>
      <Name>Midea Heat Pump</Name>
      <Id>-1</Id>
      <Model>ModbusModule</Model>
      <DeviceProperties>
        <DeviceType>7001</DeviceType>
        <InternalPollInterval>30000</InternalPollInterval>
        <PrefetchModeId>0</PrefetchModeId>
        <ServiceAttributesFormulas>[{"AttributeDefinition":{"Name":"Attribute"},"ReadFormula":""},{"AttributeDefinition":{"Name":"Software version"},"ReadFormula":"MODBUSR(H, 130, UInt16)"}]</ServiceAttributesFormulas>
        <ServiceActionsScripts>[]</ServiceActionsScripts>
        <SlaveId>$[SlaveId]</SlaveId>
        <ModuleVariables>[]</ModuleVariables>
        <MaxPrefetchGroupSize>100</MaxPrefetchGroupSize>
        <IpAddress>$[IpAddress]</IpAddress>
      </DeviceProperties>
      <Devices>
        <Device>
          <Name>Calculated Water temperature</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-2</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 110, Int16) </ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Capacity</Name>
          <Model>ModbusVariable</Model>
          <Id>-3</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"60":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:60}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 140, Int16) / 100</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Cielova teplota Ekvitermiky</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-4</Id>
          <DeviceProperties>
            <DeviceType>3004</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 136, Int16)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Compressor operating time</Name>
          <Model>ModbusVariable</Model>
          <Id>-5</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions />
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 122, Int16)</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>DC bus current</Name>
          <Model>ModbusVariable</Model>
          <Id>-6</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"88":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:88}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 133, Int16)</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>DC bus voltage</Name>
          <Model>ModbusVariable</Model>
          <Id>-7</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"87":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:87}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 134, Int16) *10</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Dezinfekcia</Name>
          <Model>ModbusSwitch</Model>
          <Id>-8</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <NegateState>False</NegateState>
            <OnStateIconId>60</OnStateIconId>
            <OffStateIconId>61</OffStateIconId>
            <OnStateName>${general_on}</OnStateName>
            <OffStateName>${general_off}</OffStateName>
            <ReadSwitchState>GETBIT(MODBUSR(H, 5, Int16),4) </ReadSwitchState>
            <WriteSwitchState>var reg := MODBUSR(H, 5 , UInt16);
MODBUSW(H, 5 , UInt16, SETBIT(reg,4,St));
</WriteSwitchState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Frekvencia Kompresoru</Name>
          <Model>ModbusVariable</Model>
          <Id>-9</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"58":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:58}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 100, Int16)</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Inlet water temperature</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-10</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 104, Int16)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Kurenie</Name>
          <Model>ModbusSwitch</Model>
          <Id>-11</Id>
          <DeviceProperties>
            <DeviceType>140</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <NegateState>False</NegateState>
            <OnStateIconId>351</OnStateIconId>
            <OffStateIconId>352</OffStateIconId>
            <OnStateName>${general_yes}</OnStateName>
            <OffStateName>${general_no}</OffStateName>
            <ReadSwitchState>GETBIT(MODBUSR(H, 0, Int16),1) </ReadSwitchState>
            <WriteSwitchState>var reg := MODBUSR(H, 0 , UInt16);
MODBUSW(H, 0 , UInt16, SETBIT(reg,1,St));</WriteSwitchState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Otacky ventilatora</Name>
          <Model>ModbusVariable</Model>
          <Id>-12</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions />
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 102, Int16) </ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outdoor unit current</Name>
          <Model>ModbusVariable</Model>
          <Id>-13</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"88":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:88}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 118, Int16)</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outdoor unit high pressure value</Name>
          <Model>ModbusVariable</Model>
          <Id>-14</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions />
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 116, Int16)</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outdoor unit low pressure</Name>
          <Model>ModbusVariable</Model>
          <Id>-15</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions />
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 117, Int16)</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outdoor unit voltage</Name>
          <Model>ModbusVariable</Model>
          <Id>-16</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"87":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:87}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 119, Int16) </ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outlet water temperature</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-17</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 105, Int16)</ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Režim TČ</Name>
          <Model>ModbusMultiValueSwitch</Model>
          <Id>-18</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <Value0Index>64</Value0Index>
            <Value1Index>1</Value1Index>
            <Value2Index>2</Value2Index>
            <Value3Index>3</Value3Index>
            <Value4Index>68</Value4Index>
            <Value5Index>69</Value5Index>
            <Value6Index>70</Value6Index>
            <Value7Index>71</Value7Index>
            <Value8Index>72</Value8Index>
            <Value9Index>73</Value9Index>
            <Value0Name>Auto</Value0Name>
            <Value1Name>Auto</Value1Name>
            <Value2Name>Chladenie</Value2Name>
            <Value3Name>Kurenie</Value3Name>
            <Value4Name>4</Value4Name>
            <Value5Name>5</Value5Name>
            <Value6Name>6</Value6Name>
            <Value7Name>7</Value7Name>
            <Value8Name>8</Value8Name>
            <Value9Name>9</Value9Name>
            <Value0IconId>3</Value0IconId>
            <Value1IconId>3</Value1IconId>
            <Value2IconId>2</Value2IconId>
            <Value3IconId>1</Value3IconId>
            <Value4IconId>9</Value4IconId>
            <Value5IconId>10</Value5IconId>
            <Value6IconId>11</Value6IconId>
            <Value7IconId>12</Value7IconId>
            <Value8IconId>13</Value8IconId>
            <Value9IconId>14</Value9IconId>
            <OffStateValue>-1</OffStateValue>
            <ReadSwitchState>MODBUSR(H, 1, Int16)</ReadSwitchState>
            <WriteSwitchState>MODBUSW(H, 1, Int16, Mu)</WriteSwitchState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Teplota TUV</Name>
          <Model>ModbusThermostat</Model>
          <Id>-19</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas>[]</ServiceAttributesFormulas>
            <ServiceActionsScripts>[]</ServiceActionsScripts>
            <CustomDeviceVariables>[]</CustomDeviceVariables>
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <MinTemperature>10</MinTemperature>
            <MaxTemperature>60</MaxTemperature>
            <ReadCurrentTemperature>MODBUSR(H, 115, Int16) </ReadCurrentTemperature>
            <ReadDesiredTemperature>MODBUSR(H, 4, Int16) </ReadDesiredTemperature>
            <WriteDesiredTemperature>MODBUSW(H, 4, Int16, Se)</WriteDesiredTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>TUV</Name>
          <Model>ModbusSwitch</Model>
          <Id>-20</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>2500</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <NegateState>False</NegateState>
            <OnStateIconId>60</OnStateIconId>
            <OffStateIconId>61</OffStateIconId>
            <OnStateName>${general_on}</OnStateName>
            <OffStateName>${general_off}</OffStateName>
            <ReadSwitchState>GETBIT(MODBUSR(H, 0, Int16),2) </ReadSwitchState>
            <WriteSwitchState>var reg := MODBUSR(H, 0 , UInt16);
MODBUSW(H, 0, UInt16, SETBIT(reg,2,St));</WriteSwitchState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Vonkajsia Teplota TC</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-21</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>1000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 107, Int16) </ReadTemperature>
            <ReadHumidity></ReadHumidity>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Water flow</Name>
          <Model>ModbusVariable</Model>
          <Id>-22</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <SerializedValueLogTypeConversions>{"83":"{\u0022ValueLogTypeConversionTypeId\u0022:3,\u0022SerializedValueLogTypeConversion\u0022:\u0022{\\u0022Value1OnInput\\u0022:0,\\u0022Value1OnOutput\\u0022:0,\\u0022Value2OnInput\\u0022:1,\\u0022Value2OnOutput\\u0022:1,\\u0022SourceValueLogTypes\\u0022:[62],\\u0022TargetValueLogType\\u0022:83}\u0022}"}</SerializedValueLogTypeConversions>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ShouldDoPeriodicWrite>False</ShouldDoPeriodicWrite>
            <IsReadOnly>True</IsReadOnly>
            <ReadState>MODBUSR(H, 138, Int16) / 100</ReadState>
            <WriteState></WriteState>
          </DeviceProperties>
        </Device>
      </Devices>
    </Module>
  </Template>
</Templates>