﻿<?xml version="1.0" encoding="utf-8"?>
<Templates format="2" protocolVersion="54">
  <Template id="350a1a63-bdee-4c09-be03-e76b838b43b2" revision="1.0">
    <Name>IntesisBox General System Control</Name>
    <CcuModel>ModbusRtuCCU</CcuModel>
    <Producer>intesis</Producer>
    <Model></Model>
    <Category>6</Category>
    <Description></Description>
    <RevisionHistory>
      <Revision id="1.0">Initial version</Revision>
    </RevisionHistory>
    <SuggestedCCUParameters>
      <Baudrate>9600</Baudrate>
      <DataBits>8</DataBits>
      <Parity>None</Parity>
      <StopBits>One</StopBits>
    </SuggestedCCUParameters>
    <ImportParameters>
      <Parameter>
        <Name>${device_SlaveId}</Name>
        <Value>1</Value>
        <Id>SlaveId</Id>
      </Parameter>
      <Parameter>
        <Name>${ipAddress}</Name>
        <Value>192.168.0.1</Value>
        <Id>IpAddress</Id>
      </Parameter>
    </ImportParameters>
    <Module>
      <Name>IntesisBox General System Control</Name>
      <Id>-1</Id>
      <Model>ModbusModule</Model>
      <DeviceProperties>
        <SlaveId>$[SlaveId]</SlaveId>
        <IpAddress>$[IpAddress]</IpAddress>
      </DeviceProperties>
      <Devices>
        <Device>
          <Name>System On/Off</Name>
          <Id>-2</Id>
          <Model>ModbusSwitch</Model>
          <DeviceProperties>
            <InternalPollInterval>15000</InternalPollInterval>
            <ReadSwitchState>MODBUSR(H, 0, Uint16)</ReadSwitchState>
            <WriteSwitchState>MODBUSWNE(H, 0, Uint16, St)</WriteSwitchState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outdoor temperature [°C]</Name>
          <Id>-3</Id>
          <Model>ModbusVariable</Model>
          <DeviceProperties>
            <InternalPollInterval>15000</InternalPollInterval>
            <ReadState>MODBUSR(H, 1, Int16)</ReadState>
            <WriteState>MODBUSWNE(H, 1, Int16, Va)</WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Outgoing water temperature [°C]</Name>
          <Id>-4</Id>
          <Model>ModbusVariable</Model>
          <DeviceProperties>
            <InternalPollInterval>15000</InternalPollInterval>
            <ReadState>MODBUSR(H, 2, Uint16)</ReadState>
            <WriteState>MODBUSWNE(H, 2, Uint16, Va)</WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Ingoing water temperature [°C]</Name>
          <Id>-5</Id>
          <Model>ModbusVariable</Model>
          <DeviceProperties>
            <InternalPollInterval>15000</InternalPollInterval>
            <ReadState>MODBUSR(H, 3, Uint16)</ReadState>
            <WriteState>MODBUSWNE(H, 3, Uint16, Va)</WriteState>
          </DeviceProperties>
        </Device>
        <Device>
          <Name>Operating mode</Name>
          <Id>-6</Id>
          <Model>ModbusMultiValueSwitch</Model>
          <DeviceProperties>
            <InternalPollInterval>15000</InternalPollInterval>
            <ReadSwitchState>MODBUSR(H, 4, Unt16)</ReadSwitchState>
            <WriteSwitchState>MODBUSWNE(H, 4, Uint16, Mu)</WriteSwitchState>
            <Value0IconId>0</Value0IconId>
            <Value0Name>None</Value0Name>
            <Value1IconId>1</Value1IconId>
            <Value1Name>Heat</Value1Name>
            <Value2IconId>37</Value2IconId>
            <Value2Name>Heat/Tank</Value2Name>
            <Value3IconId>49</Value3IconId>
            <Value3Name>Tank</Value3Name>
            <Value4IconId>28</Value4IconId>
            <Value4Name>Cool/Tank</Value4Name>
            <Value5IconId>2</Value5IconId>
            <Value5Name>Cool</Value5Name>
            <Value6Index>64</Value6Index>
            <Value7Index>65</Value7Index>
            <Value8Index>66</Value8Index>
            <Value9Index>67</Value9Index>
          </DeviceProperties>
        </Device>
      </Devices>
    </Module>
  </Template>
</Templates>