﻿<?xml version="1.0" encoding="utf-8"?>
<Templates format="2" protocolVersion="83">
  <Template revision="1.0" id="29f5605f-26fc-46ba-8b08-be702e59c974">
    <SuggestedCCUParameters>
      <UseAsciiCommunication>False</UseAsciiCommunication>
      <StopBits>One</StopBits>
      <DataBits>8</DataBits>
      <Parity>None</Parity>
      <Baudrate>9600</Baudrate>
      <DelayBetweenRequests>-1</DelayBetweenRequests>
      <ReadWriteTimeout>200</ReadWriteTimeout>
    </SuggestedCCUParameters>
    <ImportParameters>
      <Parameter>
        <Id>SlaveId</Id>
        <Name>Slave Id</Name>
        <Value>1</Value>
      </Parameter>
      <Parameter>
        <Id>IpAddress</Id>
        <Name>IP address</Name>
        <Value>192.168.1.0</Value>
      </Parameter>
    </ImportParameters>
    <RevisionHistory>
      <Revision id="1.0">Initial version</Revision>
    </RevisionHistory>
    <Name>CWT-THxxx</Name>
    <CcuModel>ModbusRtuCCU</CcuModel>
    <Producer></Producer>
    <Model></Model>
    <Description></Description>
    <Module>
      <Name>CWT-THxxx</Name>
      <Id>-1</Id>
      <Model>ModbusModule</Model>
      <DeviceProperties>
        <DeviceType>7001</DeviceType>
        <InternalPollInterval>30000</InternalPollInterval>
        <PrefetchModeId>0</PrefetchModeId>
        <ServiceAttributesFormulas>[{"AttributeDefinition":{"Name":"Slave ID"},"ReadFormula":"modbusr(H, 2000, Uint16)"},{"AttributeDefinition":{"Name":"Baud Rate"},"ReadFormula":"switch( modbusr(H, 2001, Uint16),\r\n0, \u00222400\u0022,\r\n1, \u00224800\u0022,\r\n2, \u00229600\u0022,\r\n\u0022Unknown\u0022)"}]</ServiceAttributesFormulas>
        <ServiceActionsScripts>[{"ActionDefinition":{"Name":"Set Slave ID","NumericParameters":[{"FriendlyName":"ID","Abbreviation":"ID","IsFloat":false,"MinValue":1,"MaxValue":254}],"BoolParameters":[],"EnumParameters":[]},"Script":"modbusw(H, 2000, Uint16, ID)"},{"ActionDefinition":{"Name":"Set Baud Rate","NumericParameters":[],"BoolParameters":[],"EnumParameters":[{"FriendlyName":"Baud Rate","Abbreviation":"bps","Values":[{"Item1":0,"Item2":"2400"},{"Item1":1,"Item2":"4800"},{"Item1":2,"Item2":"9600"}]}]},"Script":"modbusw(H, 2001, Uint16, bps)"}]</ServiceActionsScripts>
        <SlaveId>$[SlaveId]</SlaveId>
        <MaxPrefetchGroupSize>100</MaxPrefetchGroupSize>
        <IpAddress>$[IpAddress]</IpAddress>
      </DeviceProperties>
      <Devices>
        <Device>
          <Name>${temperatureSensor}</Name>
          <Model>ModbusTemperatureSensor</Model>
          <Id>-2</Id>
          <DeviceProperties>
            <DeviceType>0</DeviceType>
            <InternalPollInterval>15000</InternalPollInterval>
            <InitializeScript></InitializeScript>
            <ReadScript></ReadScript>
            <PrefetchModeId>0</PrefetchModeId>
            <ServiceAttributesFormulas></ServiceAttributesFormulas>
            <ServiceActionsScripts></ServiceActionsScripts>
            <CustomDeviceVariables />
            <ReadTemperature>MODBUSR(H, 1, Int16) / 10</ReadTemperature>
            <ReadHumidity>MODBUSR(H, 0, Uint16) / 1000</ReadHumidity>
          </DeviceProperties>
        </Device>
      </Devices>
    </Module>
  </Template>
</Templates>